Page 2
XP25
I. OVERVIEW
Model Number identification
230 -02
P 25 XXX
-
-
Unit Type
P = Heat Pump
Series
Nominal Cooling Capacity
024 = 2 tons
036 = 3 tons
048 = 4 tons
060 = 5 tons
Minor Revision Number
Voltage
230 = 208/230V-1ph-60hz
Refrigerant Type
X = R-410A
X
Typical Serial Number Identification
8 09
C
Year Code
08 = 2008
09 = 2009
10 = 2010
Month Code
A = January
B = February
C = March
05716
5 (or 6) Digit Unique Number
Location Code
19 = Saltillo, Mexico
58 = Marshalltown, IA
5
Specifications
Model Number
Unit
Outdoor Fan
Sound Rating Number (dB)
1
Factory Refrigerant
Charge
2
Number of Blades
Diameter - inches.
Maximum
Minimum
XP25-024-230-01
68
58
11 lbs., 5 oz.
3
26
Model Number
Unit
Outdoor Fan
Sound Rating Number (dB)
1
Factory Refrigerant
Charge
2
Number of Blades
Diameter - inches.
Maximum
Minimum
XP25-036-230-01
73
58
11 lbs., 8 oz.
3
26
Model Number
Unit
Outdoor Fan
Sound Rating Number (dB)
1
Factory Refrigerant
Charge
2
Number of Blades
Diameter - inches.
Maximum
Minimum
XP25-048-230-01
74
64
13 lbs., 14 oz.
3
26
Model Number
Unit
Outdoor Fan
Sound Rating Number (dB)
1
Factory Refrigerant
Charge
2
Number of Blades
Diameter - inches.
Maximum
Minimum
XP25-060-230-01
74
64
13 lbs., 0 oz.
3
26
1
Tested according to AHRI Standard 270-2008 test conditions.
2