XP17 - 2 to 5 Ton Heat Pump / Page 31
AHRI SYSTEM MATCHES
Model No.
Cooling
Capacity SEER EER
Heat Capacity Heat COP HSPF
(IV)
Coil or
Air Handler
Furnace
AHRI
Reference
High
Low
High Low
XP17-042-230 39,000 15.00 12.20 35,400 22,400 3.36 2.48 8.70 CH33-43
ML180UH090XE48B
4671994
XP17-042-230 38,500 15.00 12.20 35,000 22,000 3.32 2.44 8.50 CH33-43
ML180UH110E60C
4666901
XP17-042-230 38,500 15.00 12.20 35,000 22,000 3.32 2.44 8.50 CH33-43
ML180UH110XE60C
4672125
XP17-042-230 39,000 14.20 11.70 35,800 22,600 3.32 2.40 8.50 CH33-43
SLP98UH070XV36B
5136910
XP17-042-230 38,500 14.70 12.20 35,200 22,200 3.32 2.44 8.50 CH33-43
SLP98UH090XV36C
5136911
XP17-042-230 39,000 15.00 12.20 35,200 22,200 3.34 2.46 8.70 CH33-43
SLP98UH090XV48C
5136912
XP17-042-230 38,500 15.00 12.20 34,800 22,000 3.30 2.46 8.50 CH33-43
SLP98UH090XV60C
5136913
XP17-042-230 39,000 15.00 12.20 35,200 22,200 3.36 2.48 8.70 CH33-43
SLP98UH110XV60C
5136914
XP17-042-230 39,500 14.70 12.20 35,600 22,400 3.40 2.48 8.70 CH33-43B
SL280UH090V36B
3894784
XP17-042-230 39,000 15.00 12.20 35,400 22,200 3.38 2.46 8.70 CH33-43B
SL280UH090V48B
3894785
XP17-042-230 39,000 15.00 12.20 35,400 22,200 3.38 2.46 8.70 CH33-43B
SL280UH090XV48B
4041798
XP17-042-230 39,000 14.00 11.70 36,000 22,800 3.26 2.38 8.50 CH33-43B
3840129
XP17-042-230 39,000 15.00 12.20 35,200 22,200 3.36 2.46 8.70 CH33-43C
EL296UH110V48C
4894975
XP17-042-230 38,500 15.20 12.50 34,600 21,800 3.32 2.46 8.70 CH33-43C
SL280UH090V60C
3894786
XP17-042-230 38,500 15.20 12.50 34,600 21,800 3.32 2.46 8.70 CH33-43C
SL280UH090XV60C
4235864
XP17-042-230 39,000 15.20 12.50 35,200 22,000 3.38 2.46 8.70 CH33-43C
SL280UH110V60C
3894787
XP17-042-230 39,000 15.20 12.50 35,200 22,000 3.38 2.46 8.70 CH33-43C
SL280UH110XV60C
4042011
XP17-042-230 38,500 13.70 11.50 35,800 22,800 3.18 2.34 8.20 CH33-43C
3840133
XP17-042-230 38,000 14.00 11.50 35,600 22,600 3.26 2.40 8.50 CH33-44/48
EL296UH070XV36B
5054784
XP17-042-230 38,000 14.50 12.00 35,400 22,200 3.34 2.44 8.70 CH33-44/48
ML180UH090E48B
4666902
XP17-042-230 38,000 14.50 12.00 35,400 22,200 3.34 2.44 8.70 CH33-44/48
ML180UH090XE48B
4671995
XP17-042-230 38,500 14.50 12.00 35,400 22,400 3.36 2.46 8.70 CH33-44/48
SL280UH090V36B
3894788
XP17-042-230 38,000 14.70 12.00 35,200 22,200 3.34 2.46 8.70 CH33-44/48
SL280UH090V48B
3894789
XP17-042-230 38,000 14.70 12.00 35,200 22,200 3.34 2.46 8.70 CH33-44/48
SL280UH090XV48B
4041799
XP17-042-230 38,000 14.00 11.50 35,600 22,600 3.26 2.40 8.50 CH33-44/48
SLP98UH070XV36B
5136915
XP17-042-230 38,000 13.70 11.20 36,000 22,800 3.24 2.36 8.20 CH33-44/48
3840144
XP17-042-230 38,500 14.50 12.00 35,200 22,200 3.26 2.40 8.50 CH33-48
EL296UH090XV36C
5054785
XP17-042-230 38,500 14.70 12.20 35,200 22,200 3.30 2.44 8.50 CH33-48
EL296UH090XV48C
5054786
XP17-042-230 38,500 14.70 12.20 35,000 22,000 3.28 2.42 8.50 CH33-48
EL296UH090XV60C
5054787
XP17-042-230 38,500 14.70 12.00 35,200 22,200 3.30 2.44 8.50 CH33-48
EL296UH110XV60C
5054788
XP17-042-230 38,500 15.00 12.20 35,000 22,000 3.32 2.44 8.70 CH33-48
ML180UH090E60C
4666903
XP17-042-230 38,500 14.70 12.20 35,000 22,000 3.30 2.44 8.50 CH33-48
ML180UH110E60C
4666904
XP17-042-230 38,500 14.70 12.20 35,000 22,000 3.30 2.44 8.50 CH33-48
ML180UH110XE60C
4672126
XP17-042-230 38,000 15.00 12.20 34,800 21,800 3.28 2.44 8.50 CH33-48
SL280UH090V60C
3894790
XP17-042-230 38,000 15.00 12.20 34,800 21,800 3.28 2.44 8.50 CH33-48
SL280UH090XV60C
4235865
XP17-042-230 38,500 14.70 12.20 35,200 22,200 3.32 2.46 8.50 CH33-48
SL280UH110V60C
3894791
XP17-042-230 38,500 14.70 12.20 35,200 22,200 3.32 2.46 8.50 CH33-48
SL280UH110XV60C
4042012
XP17-042-230 38,500 14.50 12.00 35,200 22,200 3.26 2.40 8.50 CH33-48
SLP98UH090XV36C
5136916
XP17-042-230 38,500 14.70 12.20 35,200 22,200 3.30 2.44 8.50 CH33-48
SLP98UH090XV48C
5136917
XP17-042-230 38,500 14.70 12.20 35,000 22,000 3.28 2.42 8.50 CH33-48
SLP98UH090XV60C
5136918
XP17-042-230 38,500 14.70 12.00 35,200 22,200 3.30 2.44 8.50 CH33-48
SLP98UH110XV60C
5136919
XP17-042-230 38,000 13.70 11.20 35,800 22,800 3.18 2.36 8.20 CH33-48
3840148
XP17-042-230 38,000 14.70 12.00 35,000 22,000 3.26 2.42 8.50 CH33-48C
EL195UH090XE48C
4693633
XP17-042-230 38,500 14.70 12.00 35,200 22,200 3.32 2.44 8.50 CH33-48C
EL195UH110XE60C
4693634
XP17-042-230 38,500 14.70 12.00 35,200 22,200 3.30 2.44 8.50 CH33-48C
EL296UH110V48C
4894976
XP17-042-230 39,500 15.20 12.50 35,200 22,200 3.22 2.40 8.50 CH33-49
EL195UH090XE48C
4693635
XP17-042-230 40,000 15.20 12.50 35,600 22,400 3.26 2.42 8.50 CH33-49
EL195UH110XE60C
4693636
XP17-042-230 40,000 15.00 12.50 35,600 22,400 3.24 2.40 8.50 CH33-49
EL296UH090XV36C
5054789
XP17-042-230 40,000 15.20 12.50 35,400 22,200 3.24 2.40 8.50 CH33-49
EL296UH090XV48C
5054790
XP17-042-230 39,500 15.20 12.50 35,200 22,000 3.22 2.40 8.50 CH33-49
EL296UH090XV60C
5054791
NOTES:
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines);
• Cooling Ratings - 95°F outdoor air temperature and 80 °F db/67° F wb entering indoor coil air.
• High Temperature Heating Ratings - 47° F db/43° F wb outdoor air temperature and 70 °F db entering indoor coil air.
• Low Temperature Heating Ratings - 17 °F db/15° F wb outdoor air temperature and 70 °F db entering indoor coil air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section.
When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used
(order separately).
To convert HSPF from Region IV to Region V - Divide by 1.15.