XP17 - 2 to 5 Ton Heat Pump / Page 12
SPECIFICATIONS
General
Data
Model No. XP17-024 XP17-030 XP17-036 XP17-042 XP17-048 XP17-060
Nominal Tonnage
2
2.5
3
3.5
4
5
Connections
(sweat)
Liquid line (o.d.) - in.
3/8
3/8
3/8
3/8
3/8
3/8
Vapor (Suction) line (o.d.) - in.
3/4
3/4
7/8
7/8
7/8
1-1/8
Refrigerant
1
R-410A charge furnished 10 lbs. 0 oz. 10 lbs. 2 oz. 10 lbs. 2 oz. 11 lbs. 0 oz. 14 lbs. 0 oz. 14 lbs. 8 oz.
Outdoor
Coil
Net face area
- sq. ft.
Outer coil
20.73
20.73
20.73
20.73
27.21
27.21
Inner coil
20.08
20.08
20.08
20.08
26.36
26.36
Tube diameter - in.
5/16
5/16
5/16
5/16
5/16
5/16
No. of rows
2
2
2
2
2
2
Fins per inch
22
22
22
22
22
22
Outdoor
Fan
Diameter - in.
26.2
26.2
26.2
26.2
26.2
26.2
No. of blades
5
5
5
5
5
5
Motor hp
1/3
1/3
1/3
1/3
1/3
1/3
Cfm
2300
2600
3500
3500
4230
4230
Rpm
400
450
600
600
675
675
Watts
40
57
130
130
185
185
Shipping Data -
lbs. 1 pkg.
287
287
288
312
349
356
ELECTRICAL DATA
Line voltage data - 60hz - 1 ph
208/230V
208/230V
208/230V
208/230V
208/230V
208/230V
2
Maximum overcurrent protection (amps)
30
30
35
40
50
60
3
Minimum circuit ampacity
18.9
19.6
22.9
24.4
29.3
35.0
Compressor
Rated load amps
13.5
14.1
16.7
17.9
21.8
26.4
Locked rotor amps
58.3
73.0
79.0
107.0
117.0
134
Power factor
0.99
0.99
0.97
0.92
0.96
0.96
Outdoor Fan Motor
Full load amps
2
2
2
2
2
2
CONTROLS
icomfort Wi-Fi™ Thermostat
88W58
4
Remote Outdoor Temperature
Sensor
(for dual fuel and Humiditrol
®
)
X2658
5
Discharge Temperature Sensor
88K38
ComfortSense
®
7000 Thermostat
Y0349
Outdoor Temperature Sensor
- for
ComfortSense 7000 Thermostat
X2658
OPTIONAL ACCESSORIES - ORDER SEPARATELY
Compressor Hard Start Kit
88M91
Compressor Low Ambient Cut-Off
45F08
Freezestat
3/8 in. tubing
93G35
5/8 in. tubing
50A93
Low Ambient Kit
68M04
Indoor Blower Off Delay Relay
58M81
Mild Weather Kit
33M07
Monitor Kit - Service Light
76F53
Outdoor
Thermostat Kit
Thermostat
56A87
Mounting Box
31461
Refrigerant
Line Sets
L15-41-20 L15-41-40
L15-41-30 L15-41-50
L15-65-30 L15-65-40
L15-65-50
Field Fabricate
6
Snow Guards
X8782
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Refrigerant charge sufficient for 15 ft. length of refrigerant lines.
2
HACR type breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
4
Remote Outdoor Sensor may be used with an icomfort™-enabled outdoor unit for a secondary (alternate) sensor reading. Sensor may also be used with a conventional
outdoor unit.
5
Optional for service diagnostics.
6
Adds 11-1/2 inches (292 mm) to unit height.