Table 1 − HFC−410A Normal Operating Pressures (Liquid
+
10 & Suction
+
5 psig) (XP16−XXX−230−05)
Size
−024
−036
−048
−060
Model
XP16 Only
XP16 and SPB*H4
F (
C)
Liq
Vap
Liq
Vap
Liq
Vap
Liq
Vap
Normal Operating Pressures − Cooling
First Stage (Low Capac-
ity) Pressure
65 (18.3)
226
144
220
141
224
143
230
137
75 (23.9)
260
145
254
144
259
143
267
139
85 (29.4)
301
148
295
148
302
147
311
141
95 (35.0)
346
151
340
150
346
149
357
144
105 (40.6)
396
153
389
153
396
152
398
147
115 (46.1)
451
156
444
156
450
155
453
149
Second Stage (High Ca-
pacity) Pressure
65 (18.3)
241
140
232
129
238
138
232
131
75 (23.9)
279
142
269
136
278
140
276
133
85 (29.4)
321
144
312
140
321
142
320
136
95 (35.0)
369
146
346
142
372
144
367
138
105 (40.6)
421
148
409
145
424
147
421
141
115 (46.1)
480
151
465
148
481
149
479
144
Normal Operating Pressures − Heating
First Stage (Low Capac-
ity) Pressure
50 (10)
312
112
350
115
336
114
385
108
60 (15.5)
330
130
372
136
363
135
414
126
Second Stage (High Ca-
pacity) Pressure
20 (−7.0)
299
64
321
61
289
57
332
59
30 (−1.0)
312
79
347
74
294
69
349
67
40 (4.4)
325
93
367
90
321
80
361
75
50 (10)
344
110
387
110
341
110
383
85
60 (15.5)
358
128
395
131
361
128
425
122