SAFETY RULES FOR OPERATING 

YOUR FIREPLACE

  Use only IHP glass doors, specifically de-

signed for the Villa Vista™ fireplace.

  When cleaning the fireplace, the Ashes should 

be placed in a steel container with a tight 

fitting lid and moved outdoors immediately.  

Other waste shall not be placed in this con-

tainer. The closed container of ashes should 

be placed on a non-combustible floor or on 

the ground, well away from all combustible 

materials, pending final disposal. If the ashes 

are disposed of by burial in soil or otherwise 

locally dispersed, they should be retained in 

the closed container until all cinders have 

thoroughly cooled.

CAUTION: KEEP COMBUSTIBLE MA-

TERIALS AT LEAST 48 INCHES AWAY 

FROM THE FRONT OF THE FIREPLACE 

OPENING.

CAUTION: BURN UNTREATED WOOD 

ONLY.  OTHER MATERIALS SUCH AS 

WOOD PRESERVATIVES, METAL FOILS, 

COAL, PLASTIC, GARBAGE, SULPHUR OR 

OIL MAY DAMAGE THE CATALYST.

CAUTION: DO NOT OPERATE WITH-

OUT THE CATALYTIC COMBUSTOR IN 

PLACE.

CAUTION: NEVER BURN WITH THE 

BY-PASS OPENED ExCEPT FOR FIRE 

START-UP AND WHEN RELOADING THE 

STOVE.

TABLE OF CONTENTS

Safety Rules ......................................Page 2 

The Fireplace .....................................Page 3

Introduction ......................................Page 3

Parts Required  .................................Page 3

Additional Equipment (Optional) .......Page 3

Operating The Fireplace ....................Page 4

Fuel ...................................................Page 4

Catalytic Combustor ..........................Page 4

Combustion Control  .........................Page 4 

Starting And Maintaining A Fire ........Page 5

Refuelling For Best Performance ......Page 5

Smoking – Causes And 

  Troubleshooting ..............................Page 6

Important Notes ................................Page 6

Maintaining Your  

  Fireplace  .........................................Page 6

Creosote ............................................Page 6

Chimney Maintenance .......................Page 6

Dealing With A Chimney Fire .............Page 6

Catalytic Combustor ..........................Page 6

Door Frame Care ...............................Page 7

Refractory Replacement ....................Page 7

Door Installation ...............................Page 8

Door Adjustment ...............................Page 8

Glass Care - Replacement .................Page 8

Glass Care - Cleaning ........................Page 8

Gasket Replacement  ........................Page 8

FIREPlACE INSTAllATION  ..............Page 8

locating The Fireplace ......................Page 8

Framing, Facing And Mantel ..............Page 9

Hearth Extension Requirements  .......Page 9

Fireplace / Framing Dimensions ........Page 10

Insulated Chase Construction ...........Page 11

Nailing Flanges ..................................Page 11

Facing / Mantel  .................................Page 12

HOT AIR DUCTING INSTAllATION  ..Page 13

Gravity Kit .........................................Page 13

Outside Air Kit  ..................................Page 15

Chimney System ...............................Page 16

Acbi Chimney 

  Installation Instructions ..................Page 17

Offset Chimney Installation ...............Page 18

Angled Wall Radiation Shield ............Page 19

Chimney Support Installation ............Page 20

Chimney Chase And 

  Multiple Terminations......................Page 20

Masonry Applications .......................Page 21

Installation Accessories ....................Page 22

Replacement Parts ............................Page 23

Specifications ....................................Page 23

Clearance To Combustible  ................Page 23

Chimney Components lists ..............Page 24

Product Reference Information .........Page 26

THE FIREPLACE

INTRODUCTION

The Villa Vista fireplace is an energy efficient, 

heat circulating, close combustion fireplace 

using the catalytic technology.  You will receive 

a lifetime of comfort and enjoyment from your 

fireplace provided it is maintained and oper-

ated properly.

 Please read these instructions and retain 

this manual for future reference.

  Before beginning the fireplace installation, 

consult the local authorities to obtain your 

building permit and check your local building 

codes.  Install the fireplace only as described 

in these instructions and using only IHP 

components.

 

This fireplace has been tested for CAN/UlC 

S610-M87 and ANSI/Ul 127 under report 

number 192-5237.  It has also been tested 

for EPA 40 C.F.R Part 60, section 60.532(b).  

Certificate number 518.

  The Villa Vista Fireplace is not intended for 

use with a gas log set.  Failure to follow 

these instructions will void the certification 

and the warranty of the fireplace and may 

result in an unsafe installation.

Parts Required

  Fireplace model Villa Vista

  Door set (Black, Gold, Nickel)

  louver set (Del Sol, Diamante, luna, Fiori, 

Strada)

  7" diameter chimney

*

 model Secure 

Temp

®

 ASHT+, Secure Temp S-2100+ or 

ACBI manufactured by Security Chimneys 

International™ only, including:

 

- Chimney lengths

 

- Elbows (where necessary)

 

- Radiation shield, Attic radiation shield

 

- Roof flashing

 

- Rain cap 

 

- Support

  Outside air kit (included)

Additional Equipment (optional)

  Forced Air Kit 

u

  Gravity venting system

  Panel for clean face option 

 

(only with gravity venting system)

  Fireplace Blower Kit, UZY5

  Rigid Firescreen

  ACBI Chimney Outside Air Kit 

(required  

with ACBI chimney installation)

Not tested under EPA certification. If in-

stalled, this appliance no longer qualifies 

for EPA certification.

CONGRATULATIONS!

When you purchased your new fireplace, you joined the ranks of thousands of individuals 

whose answer to their home heating needs reflects their concern for aesthetics, efficiency 

and our environment. We extend our continued support to help you achieve the maximum 

benefit and enjoyment available from your new fireplace.

Thank you for selecting a IHP fireplace as the answer to your home supplemental heat-

ing needs.

*

Available from Security Chimneys™ 

Summary of Contents for VILLA VISTA 850028M

Page 1: ...safety gate or barrier screen A French manual is available upon request Order P N 850028CF Ce manuel d installation est disponible en francais simplement en faire la demande Numéro de la pièce 850028CF Wood Burning Fireplaces P N 850028M REV L 05 2013 Villa Vista VILLA VISTA This installation manual will enable you to obtain a safe efficient and dependable installation of your fireplace system Ple...

Page 2: ...ructionconditions inadequate chimney heights adverse wind conditions and or unusualenvironmentalfactorsor conditions beyond our control WARNING The Villa Vista fireplace must be installed with an outside air kitintake whichisincludedwith the fireplace WARNING THE FIREPLACE MUST BE OPER ATED WITH THE DOORS FULLY OPENEDORDOORSFULLYCLOSED IF THE DOORS ARE LEFT PARTLY OPENED GASANDFLAMEMAYBE DRAWN OUT...

Page 3: ...on Page 20 Chimney Chase And Multiple Terminations Page 20 Masonry Applications Page 21 Installation Accessories Page 22 Replacement Parts Page 23 Specifications Page 23 Clearance To Combustible Page 23 Chimney Components Lists Page 24 Product Reference Information Page 26 THE FIREPLACE INTRODUCTION The Villa Vista fireplace is an energy efficient heat circulating close combustion fireplace using ...

Page 4: ... or 6 fires should be small fires of short duration about 30 to 60 minutes This will help cure the refractory bricks Ashes that will accumulate in the ashtray will protect it from intense heat During the first few fires of this appliance there may be some odor and smoke due to the curing of the paint dust ac cumulation and burning off of lubricants used in the manufacturing process It may set off ...

Page 5: ...ors includingchimney length and the moisture content of the wood This method of burning should be used only after operating the Villa Vista fireplace with the aircontrolopenedtoproduceahotfireforabout an hour Slow combustion can be used at night in order to reduce the heat output and prolong the burn The loading time will be between 6 10 hours Be aware that the glass will get dirty using this sett...

Page 6: ...e this may cause smoke to be drawn into the room F Do not burn wood in the area in front of the log retainers G Do not abuse the unit by burning paper or cardboard or construction material such as pressed wood plywood or lumber H Do not allow the wood to smoulder or burn withoutflame sincethiswillproduceexces sivecreosoteintheunitaswellasincreased particulate emissions MAINTAINING YOUR FIREPLACE C...

Page 7: ...c gases Figure 7 5 4 1 2 3 1 Front Refractory 2 Bottom Refractory 3 Left Side Refractory 4 Right Side Refractory 5 Back Refractory Refractory Replacement The intense heat of the fire will normally cause hairline cracks in the refractory These cracks canbeminimizedbypropercuringasdescribed in First Fires They will not normally dimin ish the effectiveness of the refractory If large cracks develop th...

Page 8: ...the door using the hinge screws see Figure 9 Figure 8 HINGE SCREWS GASKET ADJUSTEMENT SCREW DOOR HINGE SCREWS Figure 9 DO NOT USE CHEMICAL GLASS CLEANERS ON PAINTED SURFACES AS IT MAY CAUSE THE PAINT TO PEEL CAUTION DONOTALLOWWINDOWCLEANER TO GET IN CONTACT WITH DOOR GASKET OR PAINT ON FACADE OR DOOR ONCE CLOSED CONTACT OF GLASS CLEANER WITH THE FIREPLACE FACADE CAN PROVOKE PAINT PEELING OFF Gaske...

Page 9: ...Vista fireplace may be installed directly on a combustible floor The supplied safety metal strip must be positioned as fol lows One half under the front of the fireplace and the other half must extend on the floor over which the hearth extension will be built see Figure 10A The safety metal strip must cover the entire width of the fireplace The combustible floor in front of the fireplace must be c...

Page 10: ...e 11 Framing Dimensions Notes Diagrams illustrations and photographs are nottoscale consultinstallationinstructions Product designs materials dimensions specifications colorsandpricesaresubjectto change or discontinuance without notice Allframingdimensionscalculatedfor1 2 dry wallatthefireplaceface Ifsheathingthechase or finishing with other thickness materials calculations will need to be made Th...

Page 11: ...ion materials must not be in contact with the fireplace or in theenclosureframeasdescribedin Enclosure section NOTE Localcodesmaynotrequirefirestopping at the ceiling levels for outside chase installa tions However it is recommended for safety and the reduction of heat loss WARNING Ifinsulationisused thefireplace must not be placed directly against it Insulation or vapor barriers if used must firs...

Page 12: ...the unit 38 and a height of 54 from the base of the appliance see Figure 15 3 Non combustible materials such as brick stone or ceramic tile may project in front of and onto the fireplace facing see Figure 14 2 x 3 MIN 54 1 2 GYPSUMBOARD SPACER MANTEL Figure 14 2 x 3 MIN SPACER 1 2 GYPSUMBOARD NON COMBUSTIBLE FACING Figure 15 COMBUSTIBLE CAN NOT PROJECT OVER OR IN FRONT OF THE FIREPLACE 38 54 Mante...

Page 13: ...imum length See Figure 17 The height of the louver must be measured from the base of the Villa Vista fireplace to the middle point of the louver When installing the double outlet system the hotairoutletscanbeinstalledinthesameroom as the fireplace or one or both of the outlets can be installed in adjacent or upper rooms Installing the ducts at different elevations will tend to exhaust more heat ou...

Page 14: ...al heating system Malfunction of the heating system s fan will cause the furnace duct to overheat A furnace duct is only single wall and not double wall as is required for the Villa Vista fireplace hot air exhaust 7 Use only IHP grills and components as described in this manual Other grills or registers forexample maybetoorestrictive and may overheat the fireplace or ceiling 8 Do not use insulated...

Page 15: ... basement or garage 4 The air intake register should be installed where it is not likely to be blocked by snow or exposed to extreme wind and well away fromautomobileexhaustfumes gasmeters and other vents 5 Theductandregistermaybeinstalledabove or below floor level Outside Air Installation Make a 4 1 4 110 mm hole in the outside wall of the house at the chosen location From outside place the outsi...

Page 16: ...o the chimney for every 2000 feet 600 m above sea level 5 All chimney installations must include at least one support The maxi mum chimney length that can be supported by the fireplace is 20 feet 8m for ACBI chimney and 12 feet 3 7 m for ASHT chimney 6 The chimney must extend at least 3 feet 915 mm above its point of contact with the roof and at least 2 feet 610 mm higher than any wall roof or bui...

Page 17: ...stallauniversalsupportfasteningthestrapsto thesurroundingjoists ASHT Installsupport as required see Chimney Support Installation Section on Page 20 4 Puttheroofflashinginplaceandsealthejoint between the roof and the flashing with roofing pitch seeFigures25and26 Forslopingroofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashing to the roof using roofing n...

Page 18: ... 3 8 545mm 19 483mm 21 3 8 545mm CrossSlopeHoleSize Putthechimneycapinto place Washtheroofflashingwithasolvent or vinegar thenpaintitwithrust proof paint Table 2 1 Install the first elbow Turn it in the required direction ACBI To lock it in place turn 1 8 of a turn Fasten the straps attached to the elbow to the surrounding frame using nails or drywall screws ASHT and S2100 Fasten it to the chimney...

Page 19: ...SHT 15º Deviation 3 5 16 84 mm 4 5 16 110 mm 5 7 8 149 mm 7 7 16 189 mm 10 1 2 268 mm 13 5 8 346 mm 15 3 8 391 mm 16 7 16 418 mm 18 457 mm 19 1 2 495 mm 22 5 8 575 mm Length 15 11 16 398 mm 19 9 16 497 mm 25 3 8 645 mm 31 3 16 792 mm 42 3 4 1086 mm 54 3 8 1381 mm 60 15 16 1548 mm 64 13 16 1646 mm 70 9 16 1792 mm 76 3 8 1940 mm 87 2210 mm 30º Deviation 7 7 16 189 mm 9 7 16 240 mm 12 7 16 316 mm 15 ...

Page 20: ...pport When installing a support slightly lift the chim neysystemsotheweightwilllieonthesupport notonthefireplacetoreduceexpansionnoises This support has two possible uses 1 For ASHT it must be used on a roof to support the chimney 2 It may be used on a floor ceiling or roof above an offset to support the chimney above the offset 3 It may be used on a floor ceiling or roof above as a supplementary ...

Page 21: ...he middle of the oval drill a hole in the masonry chimney at 45 or 30 NOTE 45 offsets allowed in Canada only 3 Increase the size of the hole until a 45º or 30º Tubinox liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip through the hole a 45 or 30 liner elbow and connect it to the liner 6 Add a small liner secti...

Page 22: ...himney for Relining Masonry Chimneys Tubinox chimney or Projet SS 7 diameter with adaptor for installation in a masonry chimney NOTES j Projet Nova Temp HT6000 is equivalent to S2100 k Projet Nova Temp HT6103 is equivalent to ASHT l This appliance is equipped with the ASHT Chimney Adaptor When other chimney is used a chimney adaptor for the chimney will be required m Chimney Adaptor S2100 HT6000 f...

Page 23: ...r BISZY VRUW VRUW Thermo disk on offblowercontrol forBISZY VTU VTU Blower to flexible pipe adaptor BISAVF BISAVF Backdraft damper BISBD BISBD Fireplace to Flex adaptor and 2 clamps BISAF BISAF CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation Side wall 24 610 mm measured from the doors edge Ceiling 6 8 2032 mm measured from the base of the fir...

Page 24: ...rts Support Section 10 long ACBI7SL H3263 Universal Support AC10SU H3265 Roof Flashings 1 12 7 12 5 30 Adjustable ACBI7FAR H3276 8 12 12 12 30 45 Adjustable ACBI7FBR H3277 Flat Roof Flashing includes spacer and collar ACBI7FR H3275 Misc Description Cat Part No Firestop ACBI7BF H3268 Radiation Shield ACBI7RS H3269 Attic Radiation Shield ACBI7RSA H3270 Telescopic Attic Radiation Shield ACBI7RST H327...

Page 25: ...lbow 30 7LE30 7LE30 Elbow 45 7LE45 7LE45 Elbow 90 7LE90 7LE90 Rain Termination Cap regular 7LCS 7LCS Rain Termination Cap deluxe 7LCC 7LCC Supports Top Support 7LST 7LST Support Assembly 7LSA 7LSA Interior Support 7LSB 7LSB Adaptor Flexible Pipe male 7LAAM 7LAAM Adaptor Flexible Pipe female 7LAAF 7LAAF Stainless Steel Flex 5 Ft Long 7LLFLEX 7LLFLEX Adjustable Insulated Wall Radiation Shield 6 to 1...

Page 26: ...s list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required ...

Reviews: