SPB − 3 to 5 Ton R−410A Heat Pump
Outdoor Units
LOW AMBIENT CONTROL Option
(Down to 0°F)
Order one each: Speed Control Kit, Weatherproof Kit, Outdoor Fan Motor and Capacitor
Model No.
SPB036H4
SPB048H4
SPB060H4
Speed Control Kit
X5867
S
S
S
Weatherproof Kit
56N41
S
S
S
Motor
1/2 HP − 230V
69H75
S
S
S
Capacitor
with mounting bracket
53H06
S
S
S
OUTDOOR SOUND DATA
1
U it
Octave Band Sound Power Levels dBA, re 10
−12
Watts
1
Sound
R ti
1
Unit
Model No.
Center Frequency − HZ
Rating
Number
Model No.
63
125
250
500
1000
2000
4000
8000
Number
(dB)
SPB036H4
80.5
70.5
71.5
71.0
68.5
63.5
58.5
53.5
76
SPB048H4
81.0
72.5
71.5
73.0
70.5
66.0
60.5
58.5
76
SPB060H4
80.5
72.5
73.5
77.5
72.5
67.0
62.5
58.5
78
NOTE − the octave sound power data does not include tonal correction.
1
Tested according to ARI Standard 270-95 test conditions.
INSTALLATION CLEARANCES
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
ÍÍÍÍÍÍÍÍÍÍÍÍÍ
See
NOTES
See NOTES
NOTES:
Service clearance of 30 in. (762 mm) must be maintained on one
of the sides adjacent to the control box.
Clearance to one of the other three sides must be 36 in. (914 mm).
Clearance to one of the remaining two sides may be 12 in. (305
mm) and the final side may be 6 in. (152 mm).
A clearance of 24 in. (610 mm) must be maintained between two
units.
48 in. (1219 mm) clearance required on top of unit.
See
NOTES
See NOTES
Control