SPB − 3 to 5 Ton R−410A Heat Pump

 

Outdoor Units 

/ Page 11

ARI RATINGS

ARI Standard 210/240 Ratings

Capacity − Btuh

Efficiency

Total Watts

COP

I d

U it M d l N

Expansion

Cooling

High

Temp

Low

Temp

HSPF

Cool

High Low High Low

Indoor Unit Model No.

Expansion
Device

Cooling Temp.

Heating

Temp.

Heating SEER EER

IV

V

Cool

High

Heat

Low

Heat

High

Heat

Low

Heat

SPB048H4

4 TON

Air Handlers

Air Handlers

46,000

44,500

26,800 14.20 11.20 8.00 7.00 4105 4005 3425 3.26 2.30

CB30U−51 (Up−Flow)

91M02

47,000

44,500

26,400 16.00 11.70 8.20 7.00 3995 3895 3315 3.34 2.34

CBX32MV−048 (Multi−Position)

Factory TXV

47,000 45,000 26,800 15.70 11.70 8.00 6.70 3960 3990 3375 3.30 2.32

CBX27UH−060 (Up−Flow/Horizontal)

Factory TXV

47,000

44,500

26,600 14.70 11.50 8.00 7.00 4055 3970 3380 3.28 2.30

CBX32M−048 (Multi−Position)

Factory TXV

47,500 45,000 27,000 15.70 12.00 8.00 7.00 3960 3910 3320 3.38 2.38

CBX27UH−048 (Up−Flow/Horizontal)

Factory TXV

47,500

43,000

25,800 15.70 12.00 7.70 6.70 3945 4070 3400 3.10 2.22

CBX32MV−068 (Multi−Position)

Factory TXV

47,500

44,000

26,000 16.00 12.00 8.20 7.00 3935 3865 3280 3.34 2.32

4,5 

CBX32MV−060 (Multi−Position)

Factory TXV

47,500

44,500

26,800 14.50 11.20 8.00 6.70 4140 4035 3470 3.24 2.26

CBX32M−060 (Multi−Position)

Factory TXV

47,500

45,000

27,000 14.50 11.20 8.00 6.70 4170 4060 3500 3.24 2.26

CB30U−65 (Up−Flow)

91M02

Up−Flow Indoor Coils + Furnaces

Up−Flow Coils + Furnaces

47,500

43,500

26,000 15.70 11.70 7.70 6.70 4010 4110 3450 3.10 2.20 CX34−60D−6F

G60UHV−60D−135

Factory TXV

48,000

43,500

26,000 15.70 11.70 7.70 6.70 4010 4110 3455 3.10 2.20 CX34−62D−6F

G60UHV−60D−135

Factory TXV

48,000

44,000

26,200 15.70 11.70 7.70 6.70 4090 4150 3510 3.10 2.18 CX34−60D−6F

G61MPV−60D−135

Factory TXV

48,500

44,000

26,400 15.70 11.70 7.70 6.70 4130 4110 3485 3.14 2.22 CX34−62D−6F

G61MPV−60D−135

Factory TXV

Horizontal Indoor Coils

Horizontal Coils

47,000

44,000

26,800 14.00 11.00 7.70 6.70 4225 4180 3550 3.08 2.22

CH33−62D−2F

91M02

47,000

46,000

27,600 14.20 11.20 8.20 7.00 4185 3845 3360 3.50 2.40

CH23−68

91M02

Horizontal Indoor Coils + Furnaces

Horizontal Coils + Furnaces

47,500

43,500

26,000 15.70 11.70 7.70 6.70 4045 4115 3470 3.10 2.20 CH33−60D−2F

G60UHV−60D−135

91M02

47,500

43,500

26,000 15.70 11.70 7.70 6.70 4005 4080 3425 3.12 2.22 CH33−62D−2F

G60UHV−60D−135

91M02

47,500

44,000

26,400 15.50 11.50 7.70 6.70 4095 4135 3500 3.12 2.20 CH33−62D−2F

G61MPV−60D−135

91M02

NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).

1

Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refrigerant lines;

Cooling Ratings − 

95

_

F outdoor air temperature and 80

_

F db/67

_

F wb entering indoor coil air.

High Temperature Heating Ratings − 

47

_

F db/43

_

F wb outdoor air temperature and 70

_

F db entering indoor coil air.

Low Temperature Heating Ratings − 

17

_

F db/15

_

F wb outdoor air temperature and 70

_

F db entering indoor coil air.

2

Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).

3

Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (

58M81

) is recommend for field installation.

4

Blower control must be set for a time−off blower delay.

5

Most popular air handler combination.

Summary of Contents for SPB036H4

Page 1: ...NUMBER IDENTIFICATION s P B Y 1 036 H 4 4 S Major Design Sequence A 1st Generation B 2nd Generation Brand Family S T Classt Product Line Unit Type P Heat Pump Outdoor Unit Nominal Cooling Capacity To...

Page 2: ...ers or add on indoor coils with FM21 dual fuel furnace control See FM21 bulletin Controls section Also see Indoor Coils and Air Handlers sections for indoor unit data Units shipped completely factory...

Page 3: ...See Specifications table for selection Not available for 060 model and must be field fabricated COMPRESSOR Copeland Scroll Ultra Techt Two Stage Compressor Compressor features high efficiency with uni...

Page 4: ...t Refrigerant line connections and field wiring inlets are located in one central area of the cabinet See dimension drawing CONTROLS Defrost Control Solid state control furnished as standard Gives a d...

Page 5: ...1 Accessories For Touchscreen Thermostat Locking cover clear C0MISC15AE1 1 Remote sensors for C0STAT02AE1L can be applied in the following combinations 1 C0SNZN01AE1 2 C0SNZN73AE1 2 C0SNZN01AE1 and 1...

Page 6: ...17 62 Locked rotor amps 58 88 135 Power factor 0 99 0 99 0 99 Outdoor Coil Fan Motor Full load amps 1 1 1 7 1 8 Fan Motor Locked rotor amps 2 1 3 1 2 9 OPTIONAL ACCESSORIES must be ordered extra Comp...

Page 7: ...036H4 80 5 70 5 71 5 71 0 68 5 63 5 58 5 53 5 76 SPB048H4 81 0 72 5 71 5 73 0 70 5 66 0 60 5 58 5 76 SPB060H4 80 5 72 5 73 5 77 5 72 5 67 0 62 5 58 5 78 NOTE the octave sound power data does not inclu...

Page 8: ...POR LINE CONNECTION LIQUID LINE CONNECTION UNIT SUPPORT FEET 8 1 2 216 SPB036H4 T0 SPB048H4 BASE SECTION 8 3 4 222 5 1 2 140 9 1 2 241 8 1 4 210 13 1 2 343 UNIT SUPPORT FEET SPB060H4 BASE SECTION 16 7...

Page 9: ...2 CX34 18 24B 6F C33 24B 2 CX34 18 24C 6F C33 24C 2 CX34 19A 6F C33 19A 2 CX34 25A 6F C33 25A 2 CX34 25B 6F C33 25B 2 CX34 30A 6F C33 30A 2 CX34 30B 6F C33 30B 2 CX34 30C 6F C33 30C 2 CX34 31A 6F C33...

Page 10: ...4 G61MPV 36C 090 2 49L24 36 400 32 000 19 400 16 00 12 00 7 70 6 70 3000 3080 2560 3 04 2 22 CX34 43C 6F 4 G61MPV 36C 090 2 49L24 36 400 32 200 19 500 16 00 11 70 7 70 6 70 3040 3095 2585 3 04 2 20 C...

Page 11: ...62D 6F 4 G60UHV 60D 135 Factory TXV 48 000 44 000 26 200 15 70 11 70 7 70 6 70 4090 4150 3510 3 10 2 18 CX34 60D 6F 4 G61MPV 60D 135 Factory TXV 48 500 44 000 26 400 15 70 11 70 7 70 6 70 4130 4110 34...

Page 12: ...4 G60UHV 60D 135 Factory TXV 58 500 52 500 33 800 15 20 11 00 8 00 7 00 5270 5105 4510 3 02 2 20 CX34 62C 6F 4 G61MPV 60C 090 Factory TXV Down Flow Indoor Coils Down Flow Coils 55 500 53 000 33 800 1...

Page 13: ...prietary products and recommended installation Retain Reference Article when specifying products and installation by an industry reference standard If retained list standard s referenced in this secti...

Page 14: ...location in assembly d Field wiring diagrams e Dimensions internal and external construction details installation clearances recommended method of installation sizes and location of mounting boltholes...

Page 15: ...rs to remain in place until installation Specifier Note Include or remove following section as project dictates E Waste Management and Disposal Specifier Note ENVIRONMENT The disposal of packaging was...

Page 16: ...inted base section d Compressor and control box 1 Located in separate compartment inside unit 2 Insulated with thick fiberglass insulation e Control box with controls factory wired f Large removable s...

Page 17: ...truction 4 Lanced ripple edged aluminum fins 5 Coil is leak tested at factory e Entire coil to be accessible for cleaning Standard factory installed features 1 Expansion valve to be factory piped 2 Di...

Page 18: ...r s written data including product technical bulletins product catalog installation instructions and product carton installation instructions PART 3 02 EXAMINATION A Site Verification of Conditions Ve...

Page 19: ...SIONS Sections Description of Change Dimensions Added new base section view Specifications Table Refrigerant charge changed on SPB036H4 and SPB060H4 models Guide Specifications Added Guide Specificati...

Page 20: ...tment to quality Specifications Ratings and Dimensions subject to change without notice and without incurring liability Improper installation adjustment alteration service or maintenance can cause pro...

Reviews: