SPB − 3 to 5 Ton R−410A Heat Pump
Outdoor Units
ARI RATINGS
1
ARI Standard 210/240 Ratings
Capacity − Btuh
Efficiency
Total Watts
COP
I d
U it M d l N
Expansion
Cooling
High
Temp
Low
Temp
HSPF
Cool
High Low High Low
Indoor Unit Model No.
Expansion
Device
Cooling Temp.
Heating
Temp.
Heating SEER EER
IV
V
Cool
High
Heat
Low
Heat
High
Heat
Low
Heat
SPB048H4
4 TON
Air Handlers
Air Handlers
46,000
44,500
26,800 14.20 11.20 8.00 7.00 4105 4005 3425 3.26 2.30
3
CB30U−51 (Up−Flow)
2
91M02
47,000
44,500
26,400 16.00 11.70 8.20 7.00 3995 3895 3315 3.34 2.34
4
CBX32MV−048 (Multi−Position)
Factory TXV
47,000 45,000 26,800 15.70 11.70 8.00 6.70 3960 3990 3375 3.30 2.32
4
CBX27UH−060 (Up−Flow/Horizontal)
Factory TXV
47,000
44,500
26,600 14.70 11.50 8.00 7.00 4055 3970 3380 3.28 2.30
3
CBX32M−048 (Multi−Position)
Factory TXV
47,500 45,000 27,000 15.70 12.00 8.00 7.00 3960 3910 3320 3.38 2.38
4
CBX27UH−048 (Up−Flow/Horizontal)
Factory TXV
47,500
43,000
25,800 15.70 12.00 7.70 6.70 3945 4070 3400 3.10 2.22
4
CBX32MV−068 (Multi−Position)
Factory TXV
47,500
44,000
26,000 16.00 12.00 8.20 7.00 3935 3865 3280 3.34 2.32
4,5
CBX32MV−060 (Multi−Position)
Factory TXV
47,500
44,500
26,800 14.50 11.20 8.00 6.70 4140 4035 3470 3.24 2.26
3
CBX32M−060 (Multi−Position)
Factory TXV
47,500
45,000
27,000 14.50 11.20 8.00 6.70 4170 4060 3500 3.24 2.26
3
CB30U−65 (Up−Flow)
2
91M02
Up−Flow Indoor Coils + Furnaces
Up−Flow Coils + Furnaces
47,500
43,500
26,000 15.70 11.70 7.70 6.70 4010 4110 3450 3.10 2.20 CX34−60D−6F
4
G60UHV−60D−135
Factory TXV
48,000
43,500
26,000 15.70 11.70 7.70 6.70 4010 4110 3455 3.10 2.20 CX34−62D−6F
4
G60UHV−60D−135
Factory TXV
48,000
44,000
26,200 15.70 11.70 7.70 6.70 4090 4150 3510 3.10 2.18 CX34−60D−6F
4
G61MPV−60D−135
Factory TXV
48,500
44,000
26,400 15.70 11.70 7.70 6.70 4130 4110 3485 3.14 2.22 CX34−62D−6F
4
G61MPV−60D−135
Factory TXV
Horizontal Indoor Coils
Horizontal Coils
47,000
44,000
26,800 14.00 11.00 7.70 6.70 4225 4180 3550 3.08 2.22
3
CH33−62D−2F
2
91M02
47,000
46,000
27,600 14.20 11.20 8.20 7.00 4185 3845 3360 3.50 2.40
3
CH23−68
2
91M02
Horizontal Indoor Coils + Furnaces
Horizontal Coils + Furnaces
47,500
43,500
26,000 15.70 11.70 7.70 6.70 4045 4115 3470 3.10 2.20 CH33−60D−2F
4
G60UHV−60D−135
2
91M02
47,500
43,500
26,000 15.70 11.70 7.70 6.70 4005 4080 3425 3.12 2.22 CH33−62D−2F
4
G60UHV−60D−135
2
91M02
47,500
44,000
26,400 15.50 11.50 7.70 6.70 4095 4135 3500 3.12 2.20 CH33−62D−2F
4
G61MPV−60D−135
2
91M02
NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refrigerant lines;
Cooling Ratings −
95
_
F outdoor air temperature and 80
_
F db/67
_
F wb entering indoor coil air.
High Temperature Heating Ratings −
47
_
F db/43
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
Low Temperature Heating Ratings −
17
_
F db/15
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
2
Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommend for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular air handler combination.