SPB − 3 to 5 Ton R−410A Heat Pump
Outdoor Units
ARI RATINGS
1
ARI Standard 210/240 Ratings
Capacity − Btuh
Efficiency
Total Watts
COP
I d
U it M d l N
Expansion
Cooling
High
Temp
Low
Temp
HSPF
Cool
High Low High Low
Indoor Unit Model No.
Expansion
Device
Cooling Temp.
Heating
Temp.
Heating SEER EER
IV
V
Cool
High
Heat
Low
Heat
High
Heat
Low
Heat
SPB060H4
5 TON
Air Handlers
Air Handlers
57,000
51,500
32,600 15.20 11.50 8.00 7.20 4935 4905 4225 3.08 2.26
4
CBX32MV−068 (Multi−Position)
Factory TXV
57,000
52,500
33,200 15.50 11.50 8.20 7.50 4965 4680 4075 3.28 2.38
4,5
CBX32MV−060 (Multi−Position)
Factory TXV
57,500
53,000
33,600 14.50 11.20 8.50 7.50 5090 4750 4170 3.28 2.36
3
CBX32M−060 (Multi−Position)
Factory TXV
58,000
52,000
33,200 14.70 11.20 8.20 7.20 5105 4935 4350 3.08 2.24 CBX26UH−060 (Up−Flow / Horizontal)
Factory TXV
56,500 52,500 33,200 15.20 11.20 8.50 7.20 4985 4710 4115 3.26 2.36
4
CBX27UH−060 (Up−Flow/Horizontal)
Factory TXV
Up−Flow Indoor Coils
Up−Flow Coils
56,500
52,000
33,200 14.00 11.00 7.70 7.00 5130 5125 4445 2.98 2.18
3
CX34−60D−6F
Factory TXV
57,000
52,000
33,200 14.00 11.00 7.70 7.00 5140 5160 4460 2.96 2.18
3
CX34−49C−6F
Factory TXV
57,000
52,000
33,400 14.00 11.00 7.70 7.00 5135 5105 4435 2.98 2.20
3
CX34−62D−6F
Factory TXV
58,000
52,000
33,200 14.20 11.20 7.70 7.00 5150 5080 4440 3.00 2.18
3
CX34−62C−6F
Factory TXV
Up−Flow Indoor Coils + Furnaces
Up−Flow Coils + Furnaces
57,000
51,500
32,800 15.20 11.20 8.00 7.00 4990 4995 4310 3.02 2.22 CX34−60D−6F
4
G61MPV−60D−135
Factory TXV
57,000
51,500
33,000 14.50 11.20 7.70 6.70 5095 5120 4420 2.94 2.18 CX34−49C−6F
4
G61MPV−60C−110
Factory TXV
57,000
51,500
33,000 15.00 11.20 7.70 7.00 5040 5065 4365 2.98 2.22 CX34−49C−6F
4
G60UHV−60C−090
Factory TXV
57,000
51,500
33,000 15.00 11.20 7.70 7.00 5045 5085 4375 2.96 2.20 CX34−49C−6F
4
G60UHV−60C−110
Factory TXV
57,500
51,500
32,800 15.50 11.50 8.00 7.20 4995 4915 4265 3.08 2.26 CX34−60D−6F
4
G60UHV−60D−135
Factory TXV
57,500
51,500
32,800 15.20 11.50 8.00 7.00 5000 4980 4300 3.04 2.24 CX34−62D−6F
4
G61MPV−60D−135
Factory TXV
57,500
52,500
33,800 14.70 10.95 7.70 7.00 5255 5185 4525 2.96 2.18 CX34−49C−6F
4
G61MPV−60C−090
Factory TXV
58,000
51,500
33,000 15.20 11.20 8.00 7.00 5060 5005 4355 3.02 2.22 CX34−62C−6F
4
G60UHV−60C−110
Factory TXV
58,000
51,500
33,000 15.50 11.50 8.00 7.00 5050 4985 4345 3.02 2.22 CX34−62C−6F
4
G60UHV−60C−090
Factory TXV
58,000
52,000
33,200 15.00 11.20 7.70 7.00 5105 5040 4400 3.02 2.20 CX34−62C−6F
4
G61MPV−60C−110
Factory TXV
58,500
52,000
32,800 15.50 11.70 8.00 7.20 5005 4895 4255 3.12 2.26 CX34−62D−6F
4
G60UHV−60D−135
Factory TXV
58,500
52,500
33,800 15.20 11.00 8.00 7.00 5270 5105 4510 3.02 2.20 CX34−62C−6F
4
G61MPV−60C−090
Factory TXV
Down−Flow Indoor Coils
Down−Flow Coils
55,500
53,000
33,800 13.70 10.85 8.20 7.20 5120 4820 4200 3.22 2.36 CR33−50/60C−F
2
91M02
55,500
53,000
33,800 13.70 10.85 8.20 7.20 5120 4820 4200 3.22 2.36 CR33−60D−F
2
91M02
Down−Flow Indoor Coils + Furnaces
Down−Flow Coils + Furnaces
55,500
52,500
33,400 15.70 11.00 8.50 7.50 5015 4730 4100 3.26 2.38 CR33−60D−F
4
G61MPV−60D−135
2
91M02
55,500
53,000
33,600 15.50 10.95 8.20 7.20 5075 4780 4155 3.24 2.36 CR33−50/60C−F
4
G61MPV−60C−110
2
91M02
55,500
53,500
34,200 14.50 10.60 8.50 7.50 5235 4855 4270 3.22 2.34 CR33−50/60C−F
4
G61MPV−60C−090
2
91M02
56,000
52,500
33,400 15.00 11.20 8.50 7.50 4990 4685 4065 3.28 2.40 CR33−60D−F
4
G60DFV−60D−135
2
91M02
56,000
52,500
33,400 15.00 11.20 8.50 7.50 5000 4700 4080 3.28 2.40 CR33−50/60C−F
4
G60DFV−60C−110
2
91M02
56,000
53,000
33,600 15.00 11.00 8.50 7.50 5035 4700 4090 3.30 2.40 CR33−50/60C−F
4
G60DFV−60C−090
2
91M02
Horizontal Indoor Coils
Horizontal Coils
56,500
52,000
33,400 14.00 10.95 7.70 7.00 5170 5135 4460 2.96 2.20
3
CH33−60D−2F
2
91M02
56,500
52,000
33,400 14.00 11.00 7.70 7.00 5130 5110 4420 2.98 2.22
3
CH33−62D−2F
2
91M02
57,500
54,000
34,000 14.20 11.20 8.70 7.70 5145 4635 4090 3.42 2.44
3
CH23−68
2
91M02
Horizontal Indoor Coils + Furnaces
Horizontal Coils + Furnaces
56,500
51,500
32,800 15.20 11.20 7.70 7.00 4985 5040 4325 3.00 2.22 CH33−60D−2F
4
G61MPV−60D−135
2
91M02
57,000
51,500
32,800 15.20 11.20 8.00 7.00 4985 4985 4285 3.02 2.24 CH33−62D−2F
4
G61MPV−60D−135
2
91M02
57,000
51,500
32,800 15.20 11.20 8.00 7.00 4990 4955 4280 3.04 2.24 CH33−60D−2F
4
G60UHV−60D−135
2
91M02
57,500
52,000
33,000 15.20 11.50 8.00 7.20 4995 4900 4240 3.12 2.28 CH33−62D−2F
4
G60UHV−60D−135
2
91M02
NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refrigerant lines;
Cooling Ratings −
95
_
F outdoor air temperature and 80
_
F db/67
_
F wb entering indoor coil air.
High Temperature Heating Ratings −
47
_
F db/43
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
Low Temperature Heating Ratings −
17
_
F db/15
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
2
Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommend for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular air handler combination.