VENTED/UNVENTED GAS LOG APPLIANCE TECHNICAL CHART FOR MANUAL LOG SET

BTU/HR

Regulator

Gas Inlet

Valve

Model No.

Input

Gas Type

Ignition

Pres. Setting

Pressure*

Operation

Orifice Size

* For the purpose of input adjustment.

SHGL - 18MN-R

36,000

Natural

Piezo

3.5" w.c.

Max. 10.5" w.c.

Manual

0.126

25,000

Min. 5.0" w.c.

SHGL - 18MP-R

36,000

Propane/LPG

Piezo

10.0" w.c.

Max. 13" w.c.

Manual

0.071

27,000

Min. 11" w.c.

SHGL - 24MN-R

39,000

Natural

Piezo

3.5" w.c.

Max. 10.5" w.c.

Manual

0.136

26,000

Min. 5.0" w.c.

SHGL - 24MP-R

39,000

Propane/LPG

Piezo

10.0" w.c.

Max. 13" w.c.

Manual

0.074

31,000

Min. 11" w.c.

MANUAL WIRING DIAGRAM

MANUAL VALVE

PILOT ASSY

CONTROL KNOB

AND PILOT IGNITOR

IGNITION
WIRE

Summary of Contents for SERENE HEAT Series

Page 1: ...nce It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventila tion air must be provided Refer to Combustion and Ventilation Air Section Page 3 Due to hig...

Page 2: ...Theseappliancesareequippedwithaspecially designed pilot utilizing an oxygen depletion sensor ODS which responds to the amount of oxygen available in the room and shuts the heater off before the oxyge...

Page 3: ...ve a confined or unconfined space 1 Determine the volume of space ft 3 Length x Width x Height _____ ft 3 Include adjoining rooms with doorless pas sagewaysorventilationgrillsbetweenrooms Example 24 L...

Page 4: ...on requirements Refer to Fig ures 1 through 7 for clearances Note Thefollowingstepsrepresentthenormal sequence of installation Each installation is unique however and might require a different sequenc...

Page 5: ...n in Figure 4 Table 3 Step 4 Wood mantel shelf or combustible projection requirements To install a wood mantel shelf or other combustible projection directly above the fireplace firebox refer to Table...

Page 6: ...n corrosion over time Never use an open flame to check for leaks A Light the appliance refer to the lighting instructions label in the control compartment or in the Homeowner s Care and Operation Inst...

Page 7: ...20341 for propane L P G heaters Replace the test point plug after pressure measurement ensuring no gas leaks Figure 9 The heater has a unitized base a front log and a top twig It is important to follo...

Page 8: ...me Characteristics The Serene Heat Gas Log Set features a new concept in integrated burner and log design The flames from the burner travel horizontally through the log set and emerge at the knot hole...

Page 9: ...he log set effortlessly with one simple motion The Model RCL comes complete with detailed operating instructions Thermostat 89L36 FWTK Wall Switch Kit 85L87 FWSK Remote Control System Standard H0249 R...

Page 10: ...ural Piezo 1 6 3 5 w c Max 10 5 w c Millivolt 0 113 24 000 Min 5 0 w c SHGL 18VP R 36 000 Propane LPG Piezo 6 3 10 0 w c Max 13 w c Millivolt 0 069 24 000 Min 11 w c SHGL 24VN R 39 000 Natural Piezo 1...

Page 11: ...djustment SHGL 18MN R 36 000 Natural Piezo 3 5 w c Max 10 5 w c Manual 0 126 25 000 Min 5 0 w c SHGL 18MP R 36 000 Propane LPG Piezo 10 0 w c Max 13 w c Manual 0 071 27 000 Min 11 w c SHGL 24MN R 39 0...

Page 12: ...t the flame failure detector from shutting off the gas while the probe is warming up 10 Release the control knob while turning counterclockwise to the preferred setting If the knob does not pop out wh...

Page 13: ...OT TO SCALE 13 Figure 15 Figure 14 Gas Control Knob Location Pilot Location Turn Control Knob to OFF Position Manual Turn Control Knob to IGN Position Manual Figure 17 Figure 16 Pilot O F F I G N L O...

Page 14: ...rn remote wall switch OFF The pilot will remain lit for normal service 2 For complete shutdown turn remote wall switch to OFF 3 Access the lower control compartment 4 Depress gas control knob slightly...

Page 15: ...orifice Replace burner Replace gas regulator Problem will stop after a few hours of operation Superior recommends running the heater with the excess ventilation for the first few hours Turn control kn...

Page 16: ...H1683 4 Twig H1681 H1684 5 Burner H1196 H1196 6 Piezo Ignitor 10K86 10K86 7 Pilot Millivolt Natural 110344 110344 Pilot Millivolt Propane L P G 901915 901915 8 Orifice Burner NG 0 113 and 0 119 99K77...

Page 17: ...NOTE DIAGRAMS ILLUSTRATION NOT TO SCALE 17 REPLACEMENT PARTS MILLIVOLT 7 1 13 8 5 2 10 6 11 12 3 9 4 Propane Pilot Shown...

Page 18: ...H1683 4 Twig H1681 H1684 5 Burner H1196 H1196 6 Piezo Ignitor 10K86 10K86 7 Pilot Manual Natural H1201 H1201 Pilot Manual Propane 120341 120341 8 Gas Regulator Natural 110353 110353 Gas Regulator Prop...

Page 19: ...NOTE DIAGRAMS ILLUSTRATION NOT TO SCALE 19 REPLACEMENT PARTS MANUAL 7 2 5 1 9 8 12 11 6 10 3 4 Propane Pilot Shown...

Page 20: ...hanges at any time without notice in design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2...