Page 2

ML196UHE Parts Identification

FIGURE 1 

NOTE - This manual is the property of the homeowner 

and must be left with the equipment user.

Notice to Homeowner

This furnace is equipped with safety devices that protect 

you and your property. If one or more of these devices is 

activated, furnace operation will stop. If your home is left 

unattended for an extended period of time, equipment op-

eration must be checked periodically. 

If this is not possible, the water supply to the house should be 

shut off and the pipes should be drained. This will prevent prob

-

lems associated with a NO HEAT condition (frozen pipes, etc.)

 CAUTION

Before attempting to perform any service or maintenance, 

turn the electrical power to unit OFF at disconnect switch.

TOP CAP

BLOWER ACCESS PANEL

AIR INTAKE COLLAR

BLOWER MOTOR

FLUE COLLAR

HEAT EXCHANGER

PRESSURE SWITCH

GAS VALVE

INTEGRATED CONTROL

COMBUSTION AIR INDUCER

UPPER ACCESS PANEL

Summary of Contents for ML196UH

Page 1: ...tly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation and service m...

Page 2: ...extended period of time equipment op eration must be checked periodically If this is not possible the water supply to the house should be shut off and the pipes should be drained This will prevent pro...

Page 3: ...on products into the building Check that furnace vent and air intake terminal s are not obstructed in any way during all seasons Safety Instructions 1 Keep the furnace area clear and free of combustib...

Page 4: ...ng property damage personal injury or death BEFORE PLACING THE UNIT INTO OPERATION smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air a...

Page 5: ...licensed professional service technician or equivalent must annually inspect this furnace and its vent system Annually before heating season inspect furnace venting system vent cap heat exchanger and...

Page 6: ...Planned Service Annual Furnace Maintenance At the beginning of each heating season and to comply with the Lennox Limited Warranty your system should be checked as follows by a licensed professional se...

Page 7: ...tal static pressure and airflow settings are within specific operating parameters 3 Clock gas meter to ensure that the unit is operating at the specified firing rate for each stage of operation Check...

Reviews: