Adjusting Airflow Direction

Manual Swing

 - Press Air Direction to put the louver at a 

desired angle. The louver swings (upward or downward) 

at a different angle with each press of the button.

Figure 26. 

Manual Swing

When cooling

Adjust the louver downwards (horizontally).

Figure 27. 

Manual Swing - Cooling

When heating

The vertical blades are not automatic  and can be adjusted 

manually as shown below. Adjust the louver vertically. 

Figure 28. 

Manual Swing - Heating

Adjust the Air Flow Direction Left and Right

To adjust the horizontal louvers, hold the knob and move 

the  louver. You  will  find  a  knob  on  the  left-side  and  the 

right-side blades.

Figure 29. 

Airflow Adjustment - Left and Right

How to Clean the Air Filter

The filter prevents dust and other particles from entering 

the indoor unit. Dust buildup can reduce the efficiency of 

the air conditioner. For optimum efficiency, clean the air 

filter every two weeks or more frequently if you live in a 

dusty area. Replace the filter with a new one if it’s heavily 

clogged and cannot be cleaned.

1. 

Open the front panel.

Figure 30. Open Front Panel

2.  Remove the Air Filter: Press the clamps on the right 

and left sides of the air filter down slightly, then pull 

upward to remove the air filter.

Air Outlet 

Selection Switch

Figure 31. Open Front Panel

Error Codes

Number 

Cause

The number 

  of flashes 

 per second  

 

  Timer 

indicator

1

Indoor EEPROM (Electrically Erasable 

Programmable Read-Only Memory) error  

1

Off

2

Indoor and outdoor unit communication malfunction

2

Off

3

Indoor fan speed malfunction

4

Off

4

Indoor room temperature sensor error

5

Off

5

Evaporator coil temperature sensor error

6

Off

6

Refrigerant leak detection system malfunction

7

Off

10

Overload protection

1

On

11

Outdoor temperature sensor error

2

On

12

Outdoor condenser pipe sensor error

3

On

13

Discharge air temperature sensor error

4

On

14

Outdoor EEPROM (Electrically Erasable 

Programmable Read-Only Memory) error 

5

On

15

Outdoor fan speed (DC fan motor only) malfunction

6

On

16

T2b sensor error

7

On

17
18
19
20

Inverter module IPM protection

1

Flash

21

High/Low voltage protection

2

Flash

22

Compressor top overheating protection

3

Flash

23

Outdoor low temperature protection

4

Flash

Compressor drive error

5

Flash

Mode conflict

6

Flash

Compressor low-pressure protection

7

Flash

Figure 32. Error Codes

Summary of Contents for M0STAT60Q-1

Page 1: ...lean up All mini split operating conditions must be verified ac cording to these installation instructions MLA MPB and MFMA Series SINGLE ZONE MINI SPLIT SYSTEMS 208 230V Floor Mount Console 508048 01...

Page 2: ...ccessories Component Catalog Number M0STAT64Q 1 Programmable Wired Controller 15D30 Wired Controller Extension Cable 20 feet long Y8738 Indoor Outdoor Unit Match Ups Outdoor Unit Indoor Unit Voltage M...

Page 3: ...ence 1 1st Revision Voltage P 208 230V 1 phase 60hz Nominal Cooling Capacity 012 1 ton Unit Type L Low Ambient Heat Pump P Heat Pump CEILING FLOOR NON DUCTED INDOOR UNITS M FM A 012 S 4 2 P Unit Type...

Page 4: ...rated tape field provided Wiring Condensate drain line wrapped in foam insulation Refrigerant Line Set Condensate Line And Indoor Outdoor Cable field provided Tape Line set wrapped in foam insulation...

Page 5: ...2S4S P inches 34 1 4 20 1 4 21 7 8 13 1 8 13 3 8 mm 870 514 556 333 340 MLA012S4S P inches 34 1 4 20 1 4 21 3 4 12 1 4 13 3 8 mm 870 514 552 311 594 Indoor Units Hanging Brackets 2 FRONT VIEW SIDE VIE...

Page 6: ...e 6 inches 152 mm when mounted on brackets and with no obstructions on the other three sides Figure 3 Outdoor Unit Clearances Inches mm Indoor Unit FRONT VIEW SIDE VIEW 4 102 WALL SUPPLY AIR 40 1016 S...

Page 7: ...sed to strong electromagnetic forces Areas exposed to acids or alkaline detergents DO Place the unit so that it is not exposed to direct sun light Ensure the structural ceiling can support the weight...

Page 8: ...er several times per year to avoid corrosive buildup salt Some localities are adopting sound ordinances based on the unit s sound level registered from the adjacent property not from the property wher...

Page 9: ...et 12 in 305 mm 79 in 2007 mm Figure 9 Outdoor Unit Air Flow Obstructed by Snow Figure 10 Avoid Defrost Water Ice Hazard Prevailing Winds Normally wind baffles are not required for a outdoor unit Howe...

Page 10: ...l mounting brack et insert the provided drain connector into one of the 1 inch 25 mm drain holes and attached a field provided insulated drain hose to the connector Use field provid ed rubber plugs to...

Page 11: ...ength required for the application 4 Cut the selected pipes with a pipe cutter Make the cuts flat and smooth as illustrated in Figure 18 Cutting Pipe 9 0 Lean Crude Burr o Figure 18 Cutting Pipe 5 Ins...

Page 12: ...ON THE OUTSIDE OF THE FLARE MALE FLARE CONNECTION Figure 19 Making Connections Male to Female Connection 17 Once snug continue another half turn on each nut which should create a leak free joint A to...

Page 13: ...non condensables and moisture from the system Leak Test Use the following procedure to test for system leaks 1 Connect the manifold gauge set and dry nitrogen gas cylinder to the liquid and gas servic...

Page 14: ...ons are complete Indoor Unit All indoor units are powered by the outdoor unit Communication Wiring Indoor Units 30K and Below Use one stranded 4 conductor wire to provide power and communication Commu...

Page 15: ...g Factory Setting For Setting Down louver For Setting Down louver SW101 SW101 ACTIVE ACTIVE 1 1 2 2 ON ON 1 1 2 2 ON ON 1 1 2 2 ON ON 1 1 2 2 ON ON SW103 SW103 For Setting Fan Motor Control then No Po...

Page 16: ...G CN 21 Y G CN 1A Y G Y G COMPRESSOR Y G CN 50 3 U V W BLUE RED BLACK EXV OUTDOOR MAIN PCB OUTDOOR TE MP S E NS OR COMPR E S S OR DIS CHAR GE TE MP S E NS OR OUTDOOR C OIL TEMP SENSOR RED BLACK WHTIE...

Page 17: ...amount of additional refrigerant Failure to do so may result in reduced performance Table 8 Additional Refrigerant Charge System Size KBtu Pipe Length feet meters Amount of Refrigerant to add 12 25 7...

Page 18: ...failure the system will immediately stop When power returns the Operation light on the indoor unit will flash To restart the unit press the ON OFF button on the remote control If the system has an aut...

Page 19: ...Figure 30 Open Front Panel 2 Remove the Air Filter Press the clamps on the right and left sides of the air filter down slightly then pull upward to remove the air filter Air Outlet Selection Switch Fi...

Page 20: ...actory installed CN4 Adapter Cable Optional Programmable Wired Controller 20 Foot Cable provided with Programmable Wired Controller Figure 33 Connecting Optional Programmable Wired Controller Connect...

Reviews: