background image

25

    nection pipe with insulating pipe, and 

insulating pipe

1. Connect the drain hose to the outlet pipe of

outlet

pipe

drain hose

drain hose

tape

outlet pipe

drain hose

insulating pipe

 Add insulating pipe in the indoor 

 The plastic expansion particles are 

1. Open the panel, remove the screw 

    on the wiring cover and then take

wiring cover

screw

panel

Step seven: connect wire of indoor unit

4. Wrap the indoor pipe and joint of con-

    then wrap it with tape.

Step six: install drain hose

Installation of indoor unit

torque wrench

open-end 

wrench

indoor pipe

pipe

union nut

Hex nut diameter Tightening torque (N.m)

Φ 6

Φ 9.52

Φ 12
Φ 16

Φ 19

30~40

40~55
60~65

70~75

15~20

    indoor unit.

2. Bind the joint with tape.

Note:

   drain hose in order to prevent 

   condensation.

   not provided.

    down the cover.

Summary of Contents for LMO12CI-100V232-X

Page 1: ...selecting LENNOX air conditioners Please read this manual carefully before operation and keep it for further reference OWNER S MANUAL LENNOX AIR CONDITIONERS MODEL LMO12CI 100V232 X LMO12CO 100V232 X...

Page 2: ......

Page 3: ...Introduction for icons on display screen 7 Introduction for buttons on remote controller 8 Introduction for simple operation and other function 12 Replacement of batteries in remote controller 11 Eme...

Page 4: ...appliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory ormental capabilities or lack of experience and know...

Page 5: ...amage 2 Precautions Warning conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do no...

Page 6: ...ables before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket...

Page 7: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only 4 Precautions Warning wire which can t be used for other purposes The grounding resistance...

Page 8: ...injury or damage If you need to relocate the air conditioner to another must be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for...

Page 9: ...Outdoor Unit air inlet panel aux button horizontal louver air outlet heating indicator temp indicator cooling indicator power indicator receiver window drying indicator display remote controller Notic...

Page 10: ...OCK button TIMER ON button SLEEP button Send signal Turbo mode 8 heating function Set temperature Set time TIMER ON TIMER OFF Child lock Up down swing Set fan speed ventilation operation Light Temp di...

Page 11: ...Press this button again to turn off the unit Press this button to increase set temperature Holding it down above 2 seconds rapidly increases set temperature In AUTO mode set temperature is not adjusta...

Page 12: ...emote controller is selected circularly as below When selecting with remote controller or no display temperature indicator on indoor TIMER ON button 9 Press this button to initiate the auto ON timer T...

Page 13: ...ng air at super high fan speed In HEAT mode the unit will blow strong heating air at super high fan speed Caution This model hasn t outdoor ambient temperature display function While remote controller...

Page 14: ...locked is displayed In this case pressing any button blinks three times Combination of TEMP and CLOCK buttons About Energy saving Function Press TEMP and CLOCK simultaneously in COOL mode to start en...

Page 15: ...arrow direction 2 Replace two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box Note During operation point the remote control sig...

Page 16: ...on it will operate under auto mode aux button panel Clean and Maintenance Note Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not...

Page 17: ...n the filter is very dirty use the water below 45 to clean it and then put it in a shady and cool place to dry Install the filter and then close the panel cover tightly Note The filter should be clean...

Page 18: ...orroded If yes please contact dealer 5 Check whether drainage pipe is damaged 1 Disconnect power supply 2 Clean filter and indoor unit s panel 3 Check whether mounting bracket for outdoor unit is dama...

Page 19: ...oom Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re cei...

Page 20: ...door temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set t...

Page 21: ...unit again Outdoor unit has vapor Heating mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water flowing noise Air conditioner is turned on or...

Page 22: ...bove indicator diagram is only for reference Please refer to actual product for the actual indicator and position When below phenomenon occurs please turn off air conditioner and discon for service Po...

Page 23: ...east 30cm At least 300cm Space to the obstruction Space to the obstruction Space to the obstruction Space to the ceiling Space to the obstruction Space to the obstruction At least 30cm At least 15cm A...

Page 24: ...s such as welding machine medical equipment 3 The place near coast area 4 The place with oil or fumes in the air 5 The place with sulfureted gas 6 Other places with special circums tances will not aff...

Page 25: ...h national wiring regulations grounding with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock 2 The yellow green...

Page 26: ...on of piping hole according to the direction of outlet pipe The position of piping hole should be a little lower than the wall mounted frame shown as below Step three open piping hole 2 Open a piping...

Page 27: ...ing out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear lef...

Page 28: ...screw on the wiring cover and then take wiring cover screw panel Step seven connect wire of indoor unit 4 Wrap the indoor pipe and joint of con then wrap it with tape Step six install drain hose Insta...

Page 29: ...ld be all pole parting and the contact parting distance should be more than 3mm 3 Remove the wire clip connect the power connection wire to the wiring terminal according to the color tighten the screw...

Page 30: ...parately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the i...

Page 31: ...t least 3cm above the floor in order to install drain joint For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansio...

Page 32: ...h by referring to the sheet below handle screw gas pipe liquid pipe liquid valve gas valve union nut pipe joint Hex nut diameter Tightening torque N m 6 9 52 12 16 19 30 40 40 55 60 65 70 75 15 20 1 R...

Page 33: ...slightly dow nwards The drain hose can t be curved raised and fluctuant etc The water outlet can t be placed in water in order to drain smoothly Installation of outdoor unit U shaped curve wall drain...

Page 34: ...f the pressure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and ref...

Page 35: ...unit grounded securely It may cause electric leakage Does the power cord follow the speci fication It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet I...

Page 36: ...length of liquid pipe The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolong...

Page 37: ...4a Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 9 52 or 12 12 16 19 22 2 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350...

Page 38: ...n suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the po...

Page 39: ......

Page 40: ...hank you for choosing GREE air conditioner for correct operation please it carefully for consultation read this owner s manual carefully before operating the unit and keeps GWHD09ABNK3A1B GWHD12ABNK3A...

Reviews: