2 Buttons
2.1 Layout of Buttons
2.2 Functions of Buttons
Table 2.1
No.
Name
Function
1
Enter/Cancel
Function selection and cancellation.
2
Ÿ
ķ
.
Running temperature setting of the indoor unit, range:16~30
o
C.
ĸ
.
Timer setting, range:0.5-24 hr.
6
ź
3
Fan
Setting of the high/middle/low/auto fan speed.
4
Mode
Setting of the Cooling/Heating/Fan/Dry/Auto mode of the indoor unit.
5
Function
Switchover among the functions of Turbo/Save/E-heater/Blow etc..
7
Timer
Timer setting.
8
On/Off
Turn on/off the indoor unit
4+2
Ÿ0RGH
Press them for 5s under off state of the unit to enter/cancel the Memory
function(If memory is set, indoor unit after power failure and then power
recovery will resume the original setting state. If not, the indoor unit is
defaulted to be off after power recovery. Memory off is default before
delivery.).
3+6
)DQź
By pressing them at the same time under off state of the unit,
will be
displayed on the wired controller for the cooling only unit, while
will be
displayed on the wired controller for the cooling and heating unit.
2+6
Ÿź
Upon startup of the unit without malfunction or under off state of the
unit,press them at the same time for 5s to enter the lock state, in which
case,any other buttons won’t respond the press. Repress them for 5s to quit
this state.
Wired Controller(Optional)
39