3
0
Installation of outdoor unit
Step four: connect indoor and outdoor pipes
1. Remove the screw cap of valve and
aim the pipe joint at the bellmouth of
pipe.
2. Pretightening the union nut with
hand.
3. Tighten the union nut with torque
wrench by referring to the sheet
below.
gas pipe
liquid pipe
liquid
valve
gas valve
union nut
pipe joint
Hex nut diameter Tightening torque
(N.m)
ĭ
ĭ
ĭ
ĭ
ĭ
30~40
4
a
a
a
a
1. Remove the wire clip or front plate; connect the power connection wire and signal
control wire (only for cooling and heating unit) to the wiring terminal according to the
color; fix them with screws.
front plate
Indoor unit connection
POWER
L1’
S
L2’
L2
L2
L1
G
L1
(blue)
white
(blue)
white
red
black (brown)
(brown)
black
(yellow-
green
green)
(yellow-
green
green)