Parameter Name:
Increment
Parameter Value Setting
Default
1st Stage Differential
0.5ºF
0.5 to 3ºF
.5ºF
2nd Stage Differential
1.5ºF
0.5 to 8ºF
.5ºF
3rd Stage Differential
2.0ºF
0.5 to 8ºF
.5ºF
4th Stage Differential
2.5ºF
0.5 to 8ºF
.5ºF
5th Stage Differential
3.0ºF
0.5 to 8ºF
.5ºF
6th Stage Differential
3.5ºF
0.5 to 8ºF
.5ºF
Stage Delay Timers
Enabled
Enabled, Disabled
2nd Stage Delay
20 Minutes
5 to 120 Minutes
5 Min
3rd Stage Delay
20 Minutes
5 to 120 Minutes
5 Min
4th Stage Delay
20 Minutes
5 to 120 Minutes
5 Min
5thStage Delay
20 Minutes
5 to 120 Minutes
5 Min
6th Stage Delay
20 Minutes
5 to 120 Minutes
5 Min
Locked in 2nd Stage HP by Outdoor Temp
Off
Off, 40F (4C), 45F (7C), 50F (10C), 55F (13C),
Balance Point Control
Disabled
Enabled, Disabled
Defrost Target Discharge Temp
55ºF
50 to 60ºF
1ºF
Dehumidification Control Mode
Display Only
Display Only, Basic, Precision
Humidification Control Mode
Display Only
Display Only, Basic, Precision, Dew Point Control
Autochangeover Humidification Deadband
5%
5 to 10%
1ºF
Max Humidification Setpoint
45%
15 to 45%
1ºF
Max Dehumidification Setpoint
40%
40 to 60%
1ºF
OK/Humid Boundary
50%
45 to 60%
1ºF