background image

G61MPVT − 50hz 

/ Page 8

DIMENSIONS − MM − UP−FLOW POSITION SHOWN 

1

 Bottom Return

Air Opening

1

 Bottom Return

Air Opening

ELECTRICAL INLET

(Either Side)

SUPPLY AIR

OPENING

AIR FLOW

FRONT VIEW

SIDE VIEW

TOP VIEW

A

B

14

C

19

19

724

494

597

108

295 Right

248 Left

124 Right

57 Left

1016

102

49

584

356

14

GAS PIPING INLET

(Either Side)

EXHAUST AIR OUTLET

(Either Side)

CONDENSATE

TRAP CONNECTION

(Either Side)

64

476

1

 OPTIONAL

RETURN CUTOUT

(Either Side)

Up−Flow Only

1

 NOTE − 60C and 60D size units that require air volumes over 850

L/s must have one of the following:

a. Single side return air with transition, to accommodate

508 x 635 x 25 mm air filter. Required to maintain proper air velocity.

b. Bottom return air.
c. Return air from both sides.
d. Bottom and one side return air.

See Blower Performance Tables for additional information.

COMBUSTION AIR INTAKE

(Either Side)

165

103

165

171

140

79

IEC

Receptacle

Model No.

A

B

C

G61MPVT−36B−070

446

416

406

G61MPVT−60C−090
G61MPVT−60C−110

533

505

495

G61MPVT−60D−135

622

594

584

Summary of Contents for G61MPVT

Page 1: ...6 kW MODEL NUMBER IDENTIFICATION G 61 36 B 070 Unit Type G Gas Furnace Series 61 Two Stage Nominal Add On Cooling Capacity 36 10 5 kW 60 17 6 kW 1 Cabinet Width B 445 mm C 533 mm D 622 mm Gas Heat Inp...

Page 2: ...ir is supplied from outdoors and flue gases are discharged outdoors In Non Direct Vent applications combustion air is supplied from indoors and flue gases are discharged outdoors OPTIONS Termination K...

Page 3: ...for 15 seconds is initiated After the main burners are turned off a post purge cycle for 5 seconds is run Electronic flame sensor assures safe reliable operation Should flame fail to ignite flame sens...

Page 4: ...when blower compartment access door is removed Gas piping inlets are provided in both sides of cabinet Return Air Entry For bottom end return air entry for up flow horizontal applications remove furni...

Page 5: ...x 508 Blower Motor output W 373 745 745 745 kW of add on cooling 7 0 12 2 12 2 17 6 12 2 17 6 12 2 17 6 Air Volume Range L s 295 660 410 1020 350 1045 430 1035 Shipping Data kg 1 package 68 82 85 94...

Page 6: ...e collar The street ell must be included in the elbow count 3 135 models installed in down flow applications must have 80 to 50 mm 3 in to 2 in reducing elbow supplied installed directly into the flue...

Page 7: ...sed On horizontal installations the drain must be located at the bottom and the vent piping at the top FILTER AIR RESISTANCE For 25 mm Cleanable Filter Field Provided L s Pa 0 0 95 2 190 7 285 10 375...

Page 8: ...OPTIONAL RETURN CUTOUT Either Side Up Flow Only 1 NOTE 60C and 60D size units that require air volumes over 850 L s must have one of the following a Single side return air with transition to accommoda...

Page 9: ...C33 43B 724 1740 667 1683 CX34 43C 6F C33 43C 724 1740 654 1670 C33 44C 622 1638 546 1562 CX34 44 48B 6F C33 48B 622 1638 562 1578 CX34 44 48C 6F C33 48C 622 1638 546 1562 CX34 49C 6F C33 49C 749 176...

Page 10: ...RNACE A B 692 503 38 21 13 16 FLOOR OPENING 38 1 1 2 38 38 Front Of Furnace 559 C DOWN FLOW COMBUSTIBLE FLOOR BASE G61MPVT 50hz Page 10 OPTIONAL ACCESSORY DIMENSIONS MM Model No A B C G61MPVT 36B 070...

Page 11: ...metal strap must be field installed to support the weight of the termination kit FLASHING Not Furnished CLAMP GRADE Field Supplied ELBOW INTAKE AIR EXHAUST AIR TERMINATION ASSEMBLY Furnished 71M80 69...

Page 12: ...proper air velocity across the filter ADJUST Speed Switch Positions ADJUST Switch P iti Second Stage HEAT Speed L s Second Stage COOL Speed L s S tc Positions 1 1 2 3 4 1 2 3 1 4 685 775 860 970 745...

Page 13: ...ttom Return Air Return Air from Both Sides or Return Air from Bottom and One Side ADJUST Speed Switch Positions ADJUST Switch P iti Second Stage HEAT Speed L s Second Stage COOL Speed L s S tc Positio...

Page 14: ......

Page 15: ......

Page 16: ...nd Dimensions subject to change without notice and without incurring liability Improper installation adjustment alteration service or maintenance can cause property damage or personal injury Installat...

Reviews: