G61MPVT − 50hz
BLOWER DATA −
0 through 200 Pa External Static Pressure Range
G61MPVT−36B−070 BLOWER PERFORMANCE
(less filter)
ADJUST"
Speed Switch Positions
ADJUST"
Switch
P
iti
Second Stage HEAT" Speed − L/s
Second Stage COOL" Speed − L/s
S
tc
Positions
1
1
2
3
4
1
2
3
1
4
+
420
485
610
630
480
560
605
660
1
NORM
385
445
545
570
440
500
545
600
N/A
395
480
495
390
450
475
520
ADJUST"
Switch
First Stage HEAT" Speed − L/s
First Stage COOL" Speed − L/s
Switch
Positions
1
1
2
3
4
1
2
3
1
4
+
385
440
545
570
345
385
410
440
1
NORM
360
410
495
515
320
355
375
405
N/A
365
440
455
295
330
345
365
G61MPVT−60C−090 BLOWER PERFORMANCE
(less filter)
Bottom Return Air, Return Air from Both Sides or Return Air from Bottom and One Side.
ADJUST"
Speed Switch Positions
ADJUST"
Switch
P
iti
Second Stage HEAT" Speed − L/s
Second Stage COOL" Speed − L/s
S
tc
Positions
1
1
2
3
4
1
2
3
1
4
+
710
790
885
985
755
805
910
1020
1
NORM
640
730
810
895
680
735
830
925
565
645
725
800
600
650
750
830
ADJUST"
Switch
First Stage HEAT" Speed − L/s
First Stage COOL" Speed − L/s
Switch
Positions
1
1
2
3
4
1
2
3
1
4
+
640
735
815
900
520
560
640
730
1
NORM
575
665
750
820
470
510
570
635
520
580
665
740
420
455
515
575
G61MPVT−60C−090 BLOWER PERFORMANCE
(less filter)
Single Side Return Air −
Air volumes in bold require field fabricated transition to accommodate 508 x 635 x 25 mm cleanable
air filter in order to maintain proper air velocity across the filter.
ADJUST"
Speed Switch Positions
ADJUST"
Switch
P
iti
Second Stage HEAT" Speed − L/s
Second Stage COOL" Speed − L/s
S
tc
Positions
1
1
2
3
4
1
2
3
1
4
+
685
775
860
970
745
800
895
1010
1
NORM
625
710
800
885
665
722
820
915
550
625
710
785
590
640
735
820
ADJUST"
Switch
First Stage HEAT" Speed − L/s
First Stage COOL" Speed − L/s
Switch
Positions
1
1
2
3
4
1
2
3
1
4
+
620
710
800
885
510
545
620
705
1
NORM
560
645
730
810
465
500
560
630
505
570
645
715
410
440
500
560
G61MPVT−60C−110 BLOWER PERFORMANCE
(less filter)
Bottom Return Air, Return Air from Both Sides or Return Air from Bottom and One Side.
ADJUST"
Speed Switch Positions
ADJUST"
Switch
P
iti
Second Stage HEAT" Speed − L/s
Second Stage COOL" Speed − L/s
S
tc
Positions
1
1
2
3
4
1
2
3
1
4
+
710
805
905
1005
765
825
940
1045
1
NORM
645
740
830
915
690
745
845
940
570
650
740
820
610
665
755
845
ADJUST"
Switch
First Stage HEAT" Speed − L/s
First Stage COOL" Speed − L/s
Switch
Positions
1
1
2
3
4
1
2
3
1
4
+
645
740
830
920
445
480
545
615
1
NORM
580
670
755
840
395
430
495
555
520
590
670
745
350
375
434
495
1
Factory default jumper setting.
N/A − First and second stage HEAT positions shown cannot be used on this model.
NOTES − The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately
91%
of the same second stage HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately 70
%
of the same second stage COOL speed position.
Continuous Fan Only speed is approximately
38%
of the same second stage COOL speed position − minimum 235 L/s.