Page 3
OPTIONAL ACCESSORIES − MUST BE ORDERED EXTRA
A" Width Models B" Width Models C" Width Models D" Width Models
CABINET ACCESSORIES
Down−Flow Additive Base
11M59
11M60
11M61
11M62
CONTROLS
Twinning Kit
15L38
15L38
15L38
15L38
1
Cleanable polyurethane frame type filter.
HIGH ALTITUDE
Input −1
through
1
High Altitude
Orifice Kit
High Altitude Pressure
Switch Kit
LPG/Propane Kit
through
−14
g
Orifice Kit
Natural Gas Only
4501−7500 ft.
(1373 − 2286m)
7501−10,000 ft.
(2287 − 3048m)
0−7500 ft.
(0 − 2286m)
7501−10,000 ft.
(2287 − 3048m)
−044
−070
59M16
no change
no change
45L60
47M81
−090
59M16
15M22
56L32
45L60
47M81
−110
59M16
15M22
56L32
45L60
47M81
−135
59M16
49L90
15M22
45L60
47M81
Input −15
1
High Altitude
Orifice Kit
High Altitude Pressure
Switch Kit
LPG/Propane Kit
Input −15
and later
g
Orifice Kit
Natural Gas Only
4501−7500 ft.
(1373 − 2286m)
7501−10,000 ft.
(2287 − 3048m)
0−7500 ft.
(0 − 2286m)
7501−10,000 ft.
(2287 − 3048m)
−045
−070
59M17
no change
no change
25W20
25W21
−090
59M17
15M22
56L32
45L60
25W21
−110
59M17
15M22
56L32
25W20
25W21
−135
59M17
49L90
15M22
25W20
25W21
1
Required for proper operation at altitudes from 7501 to 10,000 ft.
NOTE − G40DF(X) units do NOT require a manifold change due to elevation. Manifold pressureremains the same at all
elevations.
BLOWER DATA
G40DF−24A−045 PERFORMANCE
External Static
Air Volume / Watts at Different Blower Speeds
External Static
Pressure
High
Medium
Low
in. w.g.
Pa
cfm
L/s
Watts
cfm
L/s
Watts
cfm
L/s
Watts
0.00
0
1202
565
417
1058
500
367
828
390
278
0.05
12
1185
560
410
1041
490
360
819
385
274
0.10
25
1167
550
402
1024
482
353
809
380
270
0.15
37
1147
540
396
1008
475
346
793
375
265
0.20
50
1127
530
390
991
470
338
776
365
260
0.25
62
1104
520
382
979
460
335
764
360
257
0.30
75
1081
510
374
966
455
331
752
355
254
0.40
100
1018
480
357
922
435
319
712
335
244
0.50
125
960
455
342
873
410
306
651
305
234
0.60
150
901
425
330
811
385
290
618
290
231
0.70
175
815
385
313
691
325
272
564
265
221
0.80
200
685
325
289
619
290
259
465
220
203
0.90
225
558
265
271
510
240
238
395
185
190
NOTE − All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished − field provided) in place. Also see Filter Air Resistance table.