Repair Parts List
The following repair parts are available through independent Lennox dealers. When ordering parts, include the complete furnace model number listed on the
A.G.A. or C.G.A. rating plate Example: G24M3-75. Refer to page 3 for parts identification.
CABINET PARTS
BLOWER PARTS
NOx turbulator (60 Hz. X units only)
Front access panel
Blower wheel
Hot Surface Ignitor
Blower access panel
Motor
Flame rollout switch (two)
Cabinet cap
Blower housing cut-off plate
Flame sensor
Cabinet bottom
Motor capacitor
Primary limit
Vent adapter
HEATING PARTS
Secondary limit (two)
ELECTRICAL PARTS
Heat exchanger
Pressure switch
Transformer
Main burners
Wire harness plug / cap
Control board (Hot Surface Ignition)
Main burner orifices
Flue box
Door interlock switch
Gas manifold/Burner box assembly
Combustion air blower
Gas valve
Gaskets
Low gas pressure switch (propane only)
Ignition Control Board Diagnostic Codes
DIAGNOSTIC CODES
LED #1
LED #2
DESCRIPTION
SLOW FLASH
SLOW FLASH
SIMULTANEOUS
SLOW FLASH
SLOW FLASH
FAST FLASH
ON
ON
OFF
ON
OFF
ON
SLOW FLASH
SLOW FLASH
SLOW FLASH
FAST FLASH
Primary or secondary limit switch open.
Rollout switch open. OR: 9pin connector improperly attached.
Flame sensed without gas valve energized.
Pressure switch open or has opened 5 times during a single call for heat;
OR: Blocked inlet/exhaust vent; OR: Condensate line blocked;
OR: Pressure switch closed prior to activation of combustion air blower.
Power on -- Normal operation.
Also signaled during cooling and continuous fan.
Main power polarity reversed. Switch line and neutral.
Low flame signal. Measures below .7 microAmps. Replace flame sense rod.
Circuit board failure or control wired incorrectly.
Watchguard -- burners failed to ignite.
SIMULTANEOUS
SLOW FLASH
SIMULTANEOUS
FAST FLASH
SIMULTANEOUS
FAST FLASH
Normal operation - signaled when heating demand initiated at
thermostat.
ALTERNATING
SLOW FLASH
ALTERNATING
SLOW FLASH
ON
OFF
OFF
ON
ALTERNATING
FAST FLASH
ALTERNATING
FAST FLASH
Improper main ground or line voltage below 75 volts;
OR: Broken ignitor; OR: Open ignitor circuit.
NOTE - Slow flash equals 1 Hz (one flash per second). Fast flash equals 3 Hz (three flashes per second).
Minimum flame sense current = 0.15 microAmps.