XP16 − 2 to 5 Ton Heat Pump 

/ Page 12

ARI RATINGS

ARI Standard 210/240 Ratings

Capacity − Btuh

Efficiency

Total Watts

COP

I d

U it M d l N

Expansion

Cooling

High

Temp

Low

Temp

HSPF

Cool

High Low High Low

Indoor Unit Model No.

Expansion
Device

Cooling Temp.

Heating

Temp.

Heating SEER EER

IV

V

Cool

High

Heat

Low

Heat

High

Heat

Low

Heat

XP16−048

4 TON

Up−Flow Indoor Coils

Up−Flow Coils

48,000

43,500

26,600 14.00 11.00 8.00 7.00 4365 3875 3450 3.30 2.26 CX34−62D−6F

Factory TXV

Up−Flow Indoor Coils + Furnaces

Up−Flow Coils + Furnaces

47,500

43,500

26,000 15.70 11.70 7.70 6.70 4010 4110 3450 3.10 2.20 CX34−60D−6F

G60UHV−60D−135

Factory TXV

48,000

44,000

26,200 15.70 11.70 7.70 6.70 4090 4150 3510 3.10 2.18 CX34−60D−6F

G61MPV−60D−135

Factory TXV

48,500

43,000

25,800 15.70 11.70 8.20 7.20 4145 3650 3225 3.46 2.34 CX34−62D−6F

G60UHV−60D−135

Factory TXV

48,500

43,500

26,200 15.70 11.70 8.20 7.15 4145 3730 3325 3.42 2.30 CX34−62D−6F

G61MPV−60D−135

Factory TXV

48,500

43,500

26,200 15.70 11.70 8.20 7.15 4145 3730 3325 3.42 2.30 CX34−62D−6F

G71MPP−60D−135

Factory TXV

Horizontal Indoor Coils

Horizontal Coils

47,000

44,000

26,800 14.00 11.00 7.70 6.70 4225 4180 3550 3.08 2.22

CH33−62D−2F

91M02

47,000

46,000

27,600 14.20 11.20 8.20 7.00 4185 3845 3360 3.50 2.40

CH23−68

91M02

Horizontal Indoor Coils + Furnaces

Horizontal Coils + Furnaces

47,500

43,500

26,000 15.70 11.70 7.70 6.70 4045 4115 3470 3.10 2.20 CH33−60D−2F

G60UHV−60D−135

91M02

47,500

43,500

26,000 15.70 11.70 7.70 6.70 4005 4080 3425 3.12 2.22 CH33−62D−2F

G60UHV−60D−135

91M02

47,500

44,000

26,400 15.50 11.50 7.70 6.70 4095 4135 3500 3.12 2.20 CH33−62D−2F

G61MPV−60D−135

91M02

47,500

44,000

26,400 15.50 11.50 7.70 6.70 4095 4135 3500 3.12 2.20 CH33−62D−2F

G71MPP−60D−135

91M02

XP16−060

5 TON

Air Handlers

Air Handlers

57,000

51,500

32,600 15.20 11.50 8.00 7.20 4935 4905 4225 3.08 2.26

CBX32MV−068 (Multi−Position)

Factory TXV

57,000

52,500

33,200 15.50 11.50 8.20 7.50 4965 4680 4075 3.28 2.38

4,5 

CBX32MV−060 (Multi−Position)

Factory TXV

57,500

53,000

33,600 14.50 11.20 8.50 7.50 5090 4750 4170 3.28 2.36

CBX32M−060 (Multi−Position)

Factory TXV

58,000

52,000

33,200 14.70 11.20 8.20 7.20 5105 4935 4350 3.08 2.24 CBX26UH−060 (Up−Flow / Horizontal)

Factory TXV

56,500 52,500 33,200 15.20 11.20 8.50 7.20 4985 4710 4115 3.26 2.36

CBX27UH−060 (Up−Flow/Horizontal)

Factory TXV

Up−Flow Indoor Coils

Up−Flow Coils

56,500

52,000

33,200 14.00 11.00 7.70 7.00 5130 5125 4445 2.98 2.18

CX34−60D−6F

Factory TXV

57,000

52,000

33,200 14.00 11.00 7.70 7.00 5140 5160 4460 2.96 2.18

CX34−49C−6F

Factory TXV

57,000

52,000

33,400 14.00 11.00 7.70 7.00 5135 5105 4435 2.98 2.20

CX34−62D−6F

Factory TXV

58,000

52,000

33,200 14.20 11.20 7.70 7.00 5150 5080 4440 3.00 2.18

CX34−62C−6F

Factory TXV

Up−Flow Indoor Coils + Furnaces

Up−Flow Coils + Furnaces

57,000

51,500

32,800 15.20 11.20 8.00 7.00 4990 4995 4310 3.02 2.22 CX34−60D−6F

G61MPV−60D−135

Factory TXV

57,000

51,500

32,800 15.20 11.20 8.00 7.00 4990 4995 4310 3.02 2.22 CX34−60D−6F

G71MPP−60D−135

Factory TXV

57,000

51,500

33,000 14.50 11.20 7.70 6.70 5095 5120 4420 2.94 2.18 CX34−49C−6F

G61MPV−60C−110

Factory TXV

57,000

51,500

33,000 14.50 11.20 7.70 6.70 5095 5120 4420 2.94 2.18 CX34−49C−6F

G71MPP−60C−110

Factory TXV

57,000

51,500

33,000 15.00 11.20 7.70 7.00 5040 5065 4365 2.98 2.22 CX34−49C−6F

G60UHV−60C−090

Factory TXV

57,000

51,500

33,000 15.00 11.20 7.70 7.00 5045 5085 4375 2.96 2.20 CX34−49C−6F

G60UHV−60C−110

Factory TXV

Up−Flow Indoor Coils + Furnaces

Continued on Next Page

NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).

1

Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refrigerant lines;

Cooling Ratings − 

95

_

F outdoor air temperature and 80

_

F db/67

_

F wb entering indoor coil air.

High Temperature Heating Ratings − 

47

_

F db/43

_

F wb outdoor air temperature and 70

_

F db entering indoor coil air.

Low Temperature Heating Ratings − 

17

_

F db/15

_

F wb outdoor air temperature and 70

_

F db entering indoor coil air.

2

Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).

3

Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (

58M81

) is recommend for field installation.

4

Blower control must be set for a time−off blower delay.

5

Most popular air handler combination.

Summary of Contents for Elite XP16024

Page 1: ...upersedes June 2007 SEER up to 17 0 2 to 5 Tons Cooling Capacity 23 200 to 58 500 Btuh Heating Capacity 21 200 to 54 000 Btuh MODEL NUMBER IDENTIFICATION P16 036 Unit Type P Heat Pump Series Nominal C...

Page 2: ...ionS SEER up to 17 0 Heating COP up to 3 82 HSPF region IV up to 8 70 2 through 5 ton Single phase power supply Sound levels as low as 74 dB Vertical air discharge allows concealment behind shrubs at...

Page 3: ...Senses suction line temperature and cycles the compressor off when suction line temperature falls below it s setpoint Opens at 29 F and closes at 58 F Refrigerant Line Kits Refrigerant lines suction l...

Page 4: ...thout any additional controls Kit can be added in the field enabling unit to operate properly down to 30_F A Freezestat should be installed on compressors equipped with a low ambient kit A Compressor...

Page 5: ...ull load amps 1 1 1 1 1 7 1 8 Fan Motor Locked rotor amps 2 2 1 3 1 2 9 OPTIONAL ACCESSORIES must be ordered extra ComfortSenset 7000 Thermostat Y0349 S S S S Outdoor Temperature Sensor for ComfortSen...

Page 6: ...D LINE CONNECTION D G K J E F UNIT SUPPORT FEET XP16 036 TO 060 BASE SECTION H Model No A B C D E F G H J K Model No in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm XP16 024 31 787 27 686...

Page 7: ...16 024 79 0 72 0 70 0 69 5 68 5 63 5 58 0 56 5 74 XP16 036 80 5 70 5 71 5 71 0 68 5 63 5 58 5 53 5 76 XP16 048 81 0 72 5 71 5 73 0 70 5 66 0 60 5 58 5 76 XP16 060 80 5 72 5 73 5 77 5 72 5 67 0 62 5 58...

Page 8: ...F C33 24B 2 CX34 18 24C 6F C33 24C 2 CX34 19A 6F C33 19A 2 CX34 25A 6F C33 25A 2 CX34 25B 6F C33 25B 2 CX34 30A 6F C33 30A 2 CX34 30B 6F C33 30B 2 CX34 30C 6F C33 30C 2 CX34 31A 6F C33 31A 2 CX34 31B...

Page 9: ...7 70 6 70 2010 1845 1625 3 40 2 30 CX34 25B 6F 4 G61MPV 36B 045 Factory TXV 24 000 21 600 12 900 16 00 11 70 7 70 6 70 2010 1815 1605 3 48 2 36 CX34 36B 6F 4 G61MPV 36B 045 Factory TXV 24 200 21 200...

Page 10: ...H33 36B 2F 4 G60UHV 36B 090 2 49L24 24 000 21 400 12 800 16 20 12 00 7 70 6 70 1990 1790 1580 3 50 2 38 CH33 36B 2F 4 G61MPV 36B 045 2 49L24 24 200 21 400 12 700 16 20 12 20 8 00 6 70 1955 1740 1550 3...

Page 11: ...65 2370 3 52 2 48 CR33 50 60C F 4 G61MPV 36C 090 2 49L24 36 400 33 200 20 000 16 00 12 00 8 50 7 20 3005 2765 2370 3 52 2 48 CR33 50 60C F 4 G71MPP 36C 090 2 49L24 Horizontal Indoor Coils Horizontal C...

Page 12: ...8 000 52 000 33 200 14 70 11 20 8 20 7 20 5105 4935 4350 3 08 2 24 CBX26UH 060 Up Flow Horizontal Factory TXV 56 500 52 500 33 200 15 20 11 20 8 50 7 20 4985 4710 4115 3 26 2 36 4 CBX27UH 060 Up Flow...

Page 13: ...7 20 5075 4780 4155 3 24 2 36 CR33 50 60C F 4 G71MPP 60C 110 2 91M02 55 500 53 500 34 200 14 50 10 60 8 50 7 50 5235 4855 4270 3 22 2 34 CR33 50 60C F 4 G61MPV 60C 090 2 91M02 55 500 53 500 34 200 14...

Page 14: ...SIONS Sections Description of Change ARI Ratings New rating for XP16 048 with CX34 62D coil and CX34 62D coils with furnaces ARI Ratings Removed CB30U ratings ARI Ratings Add ratings with G71MPP furna...

Page 15: ......

Page 16: ...tment to quality Specifications Ratings and Dimensions subject to change without notice and without incurring liability Improper installation adjustment alteration service or maintenance can cause pro...

Reviews: