XP16 − 2 to 5 Ton Heat Pump
ARI RATINGS
1
ARI Standard 210/240 Ratings
Capacity − Btuh
Efficiency
Total Watts
COP
I d
U it M d l N
Expansion
Cooling
High
Temp
Low
Temp
HSPF
Cool
High Low High Low
Indoor Unit Model No.
Expansion
Device
Cooling Temp.
Heating
Temp.
Heating SEER EER
IV
V
Cool
High
Heat
Low
Heat
High
Heat
Low
Heat
XP16−024
2 TON
Down−Flow Indoor Coils + Furnaces
Down−Flow Coils + Furnaces
23,800 21,800 13,100 15.70 11.70 8.00 7.00 2015 1790 1580 3.56 2.42 CR33−24B−F
4
G61MPV−36B−070
2
49L24
23,800 21,800 13,100 15.70 11.70 8.00 7.00 2015 1790 1580 3.56 2.42 CR33−24B−F
4
G71MPP−36B−070
2
49L24
23,800 21,800 13,100 15.70 11.70 8.00 7.00 2025 1795 1585 3.56 2.42 CR33−24B−F
4
G61MPV−36B−045
2
49L24
24,000 21,800 13,100 15.70 11.70 8.20 7.00 2035 1780 1575 3.58 2.44 CR33−24A−F
4
G60DFV−36A−070
2
49L24
24,200 21,800 12,900 16.20 12.20 8.20 7.20 1970 1720 1520 3.72 2.48 CR33−30/36C−F
4
G61MPV−36C−090
2
49L24
24,200 21,800 12,900 16.20 12.20 8.20 7.20 1970 1720 1520 3.72 2.48 CR33−30/36C−F
4
G71MPP−36C−090
2
49L24
24,200 21,800 13,000 16.20 12.00 8.20 7.20 2005 1730 1535 3.70 2.48 CR33−30/36B−F
4
G61MPV−36B−070
2
49L24
24,200 21,800 13,000 16.20 12.00 8.20 7.20 2005 1730 1535 3.70 2.48 CR33−30/36B−F
4
G71MPP−36B−070
2
49L24
24,200 22,000 13,100 16.20 12.00 8.20 7.20 2015 1735 1545 3.72 2.48 CR33−30/36B−F
4
G61MPV−36B−045
2
49L24
24,400 22,000 13,100 16.50 12.00 8.20 7.20 2015 1720 1540 3.74 2.50 CR33−30/36A−F
4
G60DFV−36A−070
2
49L24
24,600 22,000 13,100 16.70 12.20 8.50 7.20 2005 1690 1515 3.82 2.54 CR33−30/36B−F
4
G60DFV−36B−090
2
49L24
Horizontal Indoor Coils
Horizontal Coils
23,800 22,400 13,500 14.00 10.95 7.70 6.70 2175 1925 1745 3.42 2.26
3
CH33−36C−2F
2
49L24
Horizontal Indoor Coils + Furnaces
Horizontal Coils + Furnaces
24,000 21,400 12,700 16.20 12.00 7.70 6.70 2000 1855 1620 3.38 2.30 CH33−36A−2F
4
G60UHV−36A−070
2
49L24
24,000 21,400 12,700 16.20 12.00 8.00 6.70 1975 1785 1575 3.52 2.36 CH33−36B−2F
4
G61MPV−36B−070
2
49L24
24,000 21,400 12,700 16.20 12.00 8.00 6.70 1975 1785 1575 3.52 2.36 CH33−36B−2F
4
G71MPP−36B−070
2
49L24
24,000 21,400 12,700 16.50 12.20 8.00 6.70 1955 1765 1550 3.56 2.40 CH33−36B−2F
4
G60UHV−36B−090
2
49L24
24,000 21,400 12,800 16.20 12.00 7.70 6.70 1990 1790 1580 3.50 2.38 CH33−36B−2F
4
G61MPV−36B−045
2
49L24
24,200 21,400 12,700 16.20 12.20 8.00 6.70 1955 1740 1550 3.60 2.40 CH33−36C−2F
4
G61MPV−36C−090
2
49L24
24,200 21,400 12,700 16.20 12.20 8.00 6.70 1955 1740 1550 3.60 2.40 CH33−36C−2F
4
G71MPP−36C−090
2
49L24
XP16−036
3 TON
Air Handlers
Air Handlers
34,600 33,000 20,000 14.70 11.20 8.00 6.70 3080 2980 2550 3.24 2.30
3
CBX32M−030 (Multi−Position)
Factory TXV
35,200 33,000 19,900 15.50 11.50 8.00 7.00 3055 2900 2495 3.34 2.34
4
CBX32MV−024/030 (Multi−Position)
Factory TXV
35,200 33,200 20,000 14.70 11.20 8.00 7.00 3105 2950 2550 3.30 2.30
3
CBX32M−036 (Multi−Position)
Factory TXV
35,600 33,200 19,900 16.00 11.70 8.20 7.00 3045 2865 2480 3.40 2.34
4,5
CBX32MV−036 (Multi−Position)
Factory TXV
35,600 33,000 19,700 15.70 11.70 8.20 7.00 3000 2835 2440 3.42 2.36
4
CBX27UH−036 (Up−Flow/Horizontal)
2
49L24
35,600 33,600 20,400 14.70 11.20 8.20 7.20 3110 2895 2470 3.40 2.42 CBX26UH−030 (Up−Flow / Horizontal)
Factory TXV
36,000 33,600 20,400 14.50 11.50 8.20 7.20 3110 2865 2455 3.44 2.44 CBX26UH−036 (Up−Flow / Horizontal)
2
49L24
36,800 32,800 19,700 16.20 12.20 8.20 7.20 2970 2805 2385 3.42 2.42
4
CBX27UH−042 (Up−Flow/Horizontal)
2
49L24
Up−Flow Indoor Coils
Up−Flow Coils
35,200 33,800 20,600 14.00 11.00 8.00 7.00 3190 2995 2565 3.30 2.36
3
CX34−38A/B−6F
Factory TXV
NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refrigerant lines;
Cooling Ratings −
95
_
F outdoor air temperature and 80
_
F db/67
_
F wb entering indoor coil air.
High Temperature Heating Ratings −
47
_
F db/43
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
Low Temperature Heating Ratings −
17
_
F db/15
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
2
Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommend for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular air handler combination.