XP16 − 2 to 5 Ton Heat Pump 

/ Page 10

ARI RATINGS

ARI Standard 210/240 Ratings

Capacity − Btuh

Efficiency

Total Watts

COP

I d

U it M d l N

Expansion

Cooling

High

Temp

Low

Temp

HSPF

Cool

High Low High Low

Indoor Unit Model No.

Expansion
Device

Cooling Temp.

Heating

Temp.

Heating SEER EER

IV

V

Cool

High

Heat

Low

Heat

High

Heat

Low

Heat

XP16−024

2 TON

Down−Flow Indoor Coils + Furnaces

Down−Flow Coils + Furnaces

23,800 21,800 13,100 15.70 11.70 8.00 7.00 2015 1790 1580 3.56 2.42 CR33−24B−F

G61MPV−36B−070

49L24

23,800 21,800 13,100 15.70 11.70 8.00 7.00 2015 1790 1580 3.56 2.42 CR33−24B−F

G71MPP−36B−070

49L24

23,800 21,800 13,100 15.70 11.70 8.00 7.00 2025 1795 1585 3.56 2.42 CR33−24B−F

G61MPV−36B−045

49L24

24,000 21,800 13,100 15.70 11.70 8.20 7.00 2035 1780 1575 3.58 2.44 CR33−24A−F

G60DFV−36A−070

49L24

24,200 21,800 12,900 16.20 12.20 8.20 7.20 1970 1720 1520 3.72 2.48 CR33−30/36C−F

G61MPV−36C−090

49L24

24,200 21,800 12,900 16.20 12.20 8.20 7.20 1970 1720 1520 3.72 2.48 CR33−30/36C−F

G71MPP−36C−090

49L24

24,200 21,800 13,000 16.20 12.00 8.20 7.20 2005 1730 1535 3.70 2.48 CR33−30/36B−F

G61MPV−36B−070

49L24

24,200 21,800 13,000 16.20 12.00 8.20 7.20 2005 1730 1535 3.70 2.48 CR33−30/36B−F

G71MPP−36B−070

49L24

24,200 22,000 13,100 16.20 12.00 8.20 7.20 2015 1735 1545 3.72 2.48 CR33−30/36B−F

G61MPV−36B−045

49L24

24,400 22,000 13,100 16.50 12.00 8.20 7.20 2015 1720 1540 3.74 2.50 CR33−30/36A−F

G60DFV−36A−070

49L24

24,600 22,000 13,100 16.70 12.20 8.50 7.20 2005 1690 1515 3.82 2.54 CR33−30/36B−F

G60DFV−36B−090

49L24

Horizontal Indoor Coils

Horizontal Coils

23,800 22,400 13,500 14.00 10.95 7.70 6.70 2175 1925 1745 3.42 2.26

CH33−36C−2F

49L24

Horizontal Indoor Coils + Furnaces

Horizontal Coils + Furnaces

24,000 21,400 12,700 16.20 12.00 7.70 6.70 2000 1855 1620 3.38 2.30 CH33−36A−2F

G60UHV−36A−070

49L24

24,000 21,400 12,700 16.20 12.00 8.00 6.70 1975 1785 1575 3.52 2.36 CH33−36B−2F

G61MPV−36B−070

49L24

24,000 21,400 12,700 16.20 12.00 8.00 6.70 1975 1785 1575 3.52 2.36 CH33−36B−2F

G71MPP−36B−070

49L24

24,000 21,400 12,700 16.50 12.20 8.00 6.70 1955 1765 1550 3.56 2.40 CH33−36B−2F

G60UHV−36B−090

49L24

24,000 21,400 12,800 16.20 12.00 7.70 6.70 1990 1790 1580 3.50 2.38 CH33−36B−2F

G61MPV−36B−045

49L24

24,200 21,400 12,700 16.20 12.20 8.00 6.70 1955 1740 1550 3.60 2.40 CH33−36C−2F

G61MPV−36C−090

49L24

24,200 21,400 12,700 16.20 12.20 8.00 6.70 1955 1740 1550 3.60 2.40 CH33−36C−2F

G71MPP−36C−090

49L24

XP16−036

3 TON

Air Handlers

Air Handlers

34,600 33,000 20,000 14.70 11.20 8.00 6.70 3080 2980 2550 3.24 2.30

CBX32M−030 (Multi−Position)

Factory TXV

35,200 33,000 19,900 15.50 11.50 8.00 7.00 3055 2900 2495 3.34 2.34

CBX32MV−024/030 (Multi−Position)

Factory TXV

35,200 33,200 20,000 14.70 11.20 8.00 7.00 3105 2950 2550 3.30 2.30

CBX32M−036 (Multi−Position)

Factory TXV

35,600 33,200 19,900 16.00 11.70 8.20 7.00 3045 2865 2480 3.40 2.34

4,5 

CBX32MV−036 (Multi−Position)

Factory TXV

35,600 33,000 19,700 15.70 11.70 8.20 7.00 3000 2835 2440 3.42 2.36

CBX27UH−036 (Up−Flow/Horizontal)

49L24

35,600 33,600 20,400 14.70 11.20 8.20 7.20 3110 2895 2470 3.40 2.42 CBX26UH−030 (Up−Flow / Horizontal)

Factory TXV

36,000 33,600 20,400 14.50 11.50 8.20 7.20 3110 2865 2455 3.44 2.44 CBX26UH−036 (Up−Flow / Horizontal)

49L24

36,800 32,800 19,700 16.20 12.20 8.20 7.20 2970 2805 2385 3.42 2.42

CBX27UH−042 (Up−Flow/Horizontal)

49L24

Up−Flow Indoor Coils

Up−Flow Coils

35,200 33,800 20,600 14.00 11.00 8.00 7.00 3190 2995 2565 3.30 2.36

CX34−38A/B−6F

Factory TXV

NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).

1

Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refrigerant lines;

Cooling Ratings − 

95

_

F outdoor air temperature and 80

_

F db/67

_

F wb entering indoor coil air.

High Temperature Heating Ratings − 

47

_

F db/43

_

F wb outdoor air temperature and 70

_

F db entering indoor coil air.

Low Temperature Heating Ratings − 

17

_

F db/15

_

F wb outdoor air temperature and 70

_

F db entering indoor coil air.

2

Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).

3

Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (

58M81

) is recommend for field installation.

4

Blower control must be set for a time−off blower delay.

5

Most popular air handler combination.

Summary of Contents for Elite XP16024

Page 1: ...upersedes June 2007 SEER up to 17 0 2 to 5 Tons Cooling Capacity 23 200 to 58 500 Btuh Heating Capacity 21 200 to 54 000 Btuh MODEL NUMBER IDENTIFICATION P16 036 Unit Type P Heat Pump Series Nominal C...

Page 2: ...ionS SEER up to 17 0 Heating COP up to 3 82 HSPF region IV up to 8 70 2 through 5 ton Single phase power supply Sound levels as low as 74 dB Vertical air discharge allows concealment behind shrubs at...

Page 3: ...Senses suction line temperature and cycles the compressor off when suction line temperature falls below it s setpoint Opens at 29 F and closes at 58 F Refrigerant Line Kits Refrigerant lines suction l...

Page 4: ...thout any additional controls Kit can be added in the field enabling unit to operate properly down to 30_F A Freezestat should be installed on compressors equipped with a low ambient kit A Compressor...

Page 5: ...ull load amps 1 1 1 1 1 7 1 8 Fan Motor Locked rotor amps 2 2 1 3 1 2 9 OPTIONAL ACCESSORIES must be ordered extra ComfortSenset 7000 Thermostat Y0349 S S S S Outdoor Temperature Sensor for ComfortSen...

Page 6: ...D LINE CONNECTION D G K J E F UNIT SUPPORT FEET XP16 036 TO 060 BASE SECTION H Model No A B C D E F G H J K Model No in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm XP16 024 31 787 27 686...

Page 7: ...16 024 79 0 72 0 70 0 69 5 68 5 63 5 58 0 56 5 74 XP16 036 80 5 70 5 71 5 71 0 68 5 63 5 58 5 53 5 76 XP16 048 81 0 72 5 71 5 73 0 70 5 66 0 60 5 58 5 76 XP16 060 80 5 72 5 73 5 77 5 72 5 67 0 62 5 58...

Page 8: ...F C33 24B 2 CX34 18 24C 6F C33 24C 2 CX34 19A 6F C33 19A 2 CX34 25A 6F C33 25A 2 CX34 25B 6F C33 25B 2 CX34 30A 6F C33 30A 2 CX34 30B 6F C33 30B 2 CX34 30C 6F C33 30C 2 CX34 31A 6F C33 31A 2 CX34 31B...

Page 9: ...7 70 6 70 2010 1845 1625 3 40 2 30 CX34 25B 6F 4 G61MPV 36B 045 Factory TXV 24 000 21 600 12 900 16 00 11 70 7 70 6 70 2010 1815 1605 3 48 2 36 CX34 36B 6F 4 G61MPV 36B 045 Factory TXV 24 200 21 200...

Page 10: ...H33 36B 2F 4 G60UHV 36B 090 2 49L24 24 000 21 400 12 800 16 20 12 00 7 70 6 70 1990 1790 1580 3 50 2 38 CH33 36B 2F 4 G61MPV 36B 045 2 49L24 24 200 21 400 12 700 16 20 12 20 8 00 6 70 1955 1740 1550 3...

Page 11: ...65 2370 3 52 2 48 CR33 50 60C F 4 G61MPV 36C 090 2 49L24 36 400 33 200 20 000 16 00 12 00 8 50 7 20 3005 2765 2370 3 52 2 48 CR33 50 60C F 4 G71MPP 36C 090 2 49L24 Horizontal Indoor Coils Horizontal C...

Page 12: ...8 000 52 000 33 200 14 70 11 20 8 20 7 20 5105 4935 4350 3 08 2 24 CBX26UH 060 Up Flow Horizontal Factory TXV 56 500 52 500 33 200 15 20 11 20 8 50 7 20 4985 4710 4115 3 26 2 36 4 CBX27UH 060 Up Flow...

Page 13: ...7 20 5075 4780 4155 3 24 2 36 CR33 50 60C F 4 G71MPP 60C 110 2 91M02 55 500 53 500 34 200 14 50 10 60 8 50 7 50 5235 4855 4270 3 22 2 34 CR33 50 60C F 4 G61MPV 60C 090 2 91M02 55 500 53 500 34 200 14...