background image

18

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

REPLACEMENT PARTS 

- Elite® CVF - NG AND ELITE CVF - LP

Replacement Parts

Item #

Cat. No.

Description

1

H7009

Glass Door Assembly

2

H6060

Catalyst

3

H6061

Pilot Assembly, Natural Gas

4

H6999

Pilot Assembly, Propane Gas

5

H7010

Burner Assembly, Natural Gas

6

H7011

Burner Assembly, Propane Gas

7

H6062

Catalyst Gasket

8

H7007

Decorative Glass Facia

9a

H7002

Ball Knob

9b

H7040

Knob Spindle           

10

H7006

Hardware Kit

11

H7042

Decorative Spring-Loaded Corner Posts (4 each)

12

H7322

Fitting Template

Optional Parts

13

93L32

FFGC   Flex Gas Line Kit

7

2

9a

1

8

5

6

9b

11

12

See ordering instructions on Page 22

Hardware kits consists of the following:

 

6 ea . No .8 x 5/16 Screw Pozi Pan Head

 

6 ea . M6 x 12 Screw Pozi Pan Head BZP

 

6 ea . M4 x 12 Screw Pozi Pan Head Black

 

1 ea . Rubber Grommet

 

4 ea . Wall Plug

 

4 ea . Wall Fixing Screws

 

2 ea . Ceramic bracket

 

2 ea . Clevis Pin

u

FIREBO

X OUTLINE

C

ONT

ORNO DE LA CAMARA DE C

OMBUSTION

POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL

COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED

PIERCE TEMPLATE TO MARK

HOLE POSITION ON WALL X 4

CENTRE LINE

CONCEALED GAS INLET

ENTRADA DE GAS OCULTA

FIXING POINTS

Elite  

CVF

FIXING POINTS

PUNTOS DE SUJECION

PERFORE LA PLANTILLA PARA MARCAR

LA POSICION DE LOS 4 TALADROS EN LA PARED

PUNTOS DE SUJECION

LINEA DE CENTRO

WALL MOUNTED VENT FREE FITTING TEMPLATE

PLANTILLA PARA LA INSTALACION DE CHIMENEAS

DE PARED SIN SALIDA DE HUMOS

IMPORTANT

THIS APPLIANCE IS TO BE WALL HUNG ONLY. 

DO NOT RECESS OR INSET ANY PART OF THE APPLIANCE.

THIS TEMPLATE IS FOR THE MARKING OF FIXING POINTS ONLY.

 DO NOT INSTALL THE APPLIANCE WITH THIS TEMPLATE IN PLACE.

IMPORTANTE

ESTE APARATO UNICAMENTE DEBE SER COLGADO EN UNA PARED.

NO EMPOTRE NINGUN ELEMENTO DE ESTE APARATO.

ESTA PLANTILLA SIRVE UNICAMENTE PARA MARCAR LOS PUNTOS DE FIJACION.

RETIRE LA PLANTILLA ANTES DE COLOCAR LE APARATO.

WARNING

CLEARANCES FROM COMBUSTIBLE MATERIALS

F860041/A

The following clearances must be maintained at all times.
Failure to do so may result in the risk of a fire.
For full information refer to the instruction manual 
provided with the heater.

Note : Zero clearance from bottom of heater frame 
required for hard combustible floors. Minimum 4” 
clearance required to rugs or any fabric floor 
coverings. REFER TO INSTRUCTION MANUAL

IMPORTANT : Fabrics, curtains and drapes are not 
permited above the heater at any distance and within 
20” of the heater sides. No combustible shelves of any 
size are permitted above the heater.

Clearance to 
combustible 
sidewalls 4” 
(both sides)

Clearance to combustible ceiling 
32” measured from top of appliance 
glass panel

Clearance in 
front of 
heater 20”

F860041/A

Deben mantenerse en todo momento los siguientes espacios 
libres. El no hacerlo puede causar un riesgo de incendio. 
Consulte el manual de instrucciones suministrado con este 
aparato para obtener información completa.

Nota: No se requiere espacio libre desde el borde inferior del 
marco del calentador en caso de pisos combustibles duros. 
Se requiere un espacio mínimo de 4” entre el calentador y 
cualquier alfombra, moqueta o revestimiento de suelo de 
tela. CONSULTE EL MANUAL DE INSTRUCCIONES.

IMPORTANTE: No se permite la colocación de telas, cortinas y 

similares por encima del calentador a cualquier distancia, ni a 

una distancia de 20” de los laterales del calentador. No se 

permiten estantes combustibles de cualquier tamaño por 

encima del calentador.

Espacio hasta
paredeslaterales
combustibles
4” (ambos lados)

El espacio de 32” hasta un techo 
combustible se mide desde el borde 
superior del panel de vidrio del aparato

Espacio libre
delante del
calentador 20”

ADVERTENCIA

ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES

DO 005860/0 - ISSUE A

20-1/4”

  (515mm)

1-1/8” (28mm)

9-3/16”  (234mm)

APPLIANCE OUTLINE 

 

C

ONT

ORNO DE LA AP

ARA

TO

FocalPointFires Single   24/07/08  

DO 005860/0 Iss-B 

Lennox P23 Elite CVF fitting template

 Ref. Paul West - Focal Point Fires

Artwork Size: W605 x H960

5

4

10

Hardware

4

3

13

Summary of Contents for Elite CVF - LP

Page 1: ...ppelez le service des incindies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz AVERTISSEMENT Assurez vousdebiensui...

Page 2: ...instructions will help ensure many years of dependable and enjoyable service from your fireplace Register your product online today To help us keep you up to date on product information and offers ple...

Page 3: ...ge 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el contacto directo con el vidrio y prevenir las quemaduras...

Page 4: ...vec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cette...

Page 5: ...pliance is Not convertible for use with other gases These appliances are designed to operate on natural gas or propane gas only The use of other fuels or combinations of fuels will degrade the perform...

Page 6: ...reshowninBTUperhourandareforelevations up to 4 500 feet Do not install this heater at an elevation above 4 500 feet if the gas supply has not been derated for thatelevation Consultyourlocalgassupplier...

Page 7: ...DE FOR ALLOWABLE DISTANCES CODES Adhere to all local codes or in their absence the latest edition of The National Fuel Gas Code ANSI Z223 1 or NFPA 54 which can be obtained from The American National...

Page 8: ...___ volume of space ft3 50 ft3 Maximum BTU Hr the space can support Example 3072 ft3 50 ft3 61 44 or 61 440 BTU Hr the space can support 3 Add the BTU Hr of all the fuel burning appliances in the spac...

Page 9: ...esigned to be wall mounted alone and not in conjunction with any type of combustible fire surround No combustible shelves should be positioned on the wall above the appliance It should be established...

Page 10: ...mounted on a dry lined wall or a timber framed construction wall then special cavity screw fixings will be required which are not supplied with this product These should be constructed from metal and...

Page 11: ...and 3 8 NPT fitting A flex gas line kit with shut off valve is available see Page 18 for ordering information Route gas line using techniques and materials prescribed by local and or national codes On...

Page 12: ...urner Make sure all ports are open and producing flame evenly across the burner If any ports are blocked or partially blocked clean out the ports The heater regulator controls the burner pressure whic...

Page 13: ...g up with the appropriate hole Release the assembly when in position and secure in place by refitting the front clamping disc BRIEFING THE CUSTOMER WARNING Do not add logs or ornaments such as pine co...

Page 14: ...to ensure the spark gap is correct See specifications for gas setting NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY LIT If the pilot will not stay lit there is a problem with dirt the...

Page 15: ...als are in good condition before replacing the catalyst New seals will usually be required The performance of the catalyst may be checked using a combustion gas analyzer as follows Important The tempe...

Page 16: ...above If you do not smell gas go to next step 5 The pilot is located on the left side behind the burner Figure 13 6 Depress control knob in and turn counter clockwise to the SPARK position Figure 13...

Page 17: ...m with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY...

Page 18: ...NTILLA ANTES DE COLOCAR LE APARATO WARNING CLEARANCES FROM COMBUSTIBLE MATERIALS F860041 A The following clearances must be maintained at all times Failure to do so may result in the risk of a fire Fo...

Page 19: ...POSITIONING OF FIELD REMOVABLE PARTS Outlet Grill Main Firebox Assembly Valve Cover Plate Control Knob Spindle Control Knob Burner Assembly Burner Cover Plate Glass Door Assembly As our policy is one...

Page 20: ...NOT TO SCALE SPECIFICATIONS Elite CVF 6 1 4 23 7 8 27 3 16 9 3 16 20 1 4 Back View Top View Front View Product Reference Information Cat No Model Ship Wt Ship Volume H6072 Elite CVF NG 50 lb 4 3 cu ft...

Page 21: ...arest 1 16 KEY D1 Distance from mounting surface to rear entry point D2 Distance from mounting surface to center of side entry point D3 Distance from mounting surface to regulator gas entry point GAS...

Page 22: ...r Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance...