REPLACEMENT PARTS
- Elite® CVF - NG AND ELITE CVF - LP
Replacement Parts
Item #
Cat. No.
Description
1
H7009
Glass Door Assembly
2
H6060
Catalyst
3
H6061
Pilot Assembly, Natural Gas
4
H6999
Pilot Assembly, Propane Gas
5
H7010
Burner Assembly, Natural Gas
6
H7011
Burner Assembly, Propane Gas
7
H6062
Catalyst Gasket
8
H7007
Decorative Glass Facia
9a
H7002
Ball Knob
9b
H7040
Knob Spindle
10
H7006
Hardware Kit
11
H7042
Decorative Spring-Loaded Corner Posts (4 each)
12
H7322
Fitting Template
Optional Parts
13
93L32
FFGC Flex Gas Line Kit
7
2
9a
1
8
5
6
9b
11
12
See ordering instructions on Page 22
u
Hardware kits consists of the following:
6 ea . No .8 x 5/16 Screw Pozi Pan Head
6 ea . M6 x 12 Screw Pozi Pan Head BZP
6 ea . M4 x 12 Screw Pozi Pan Head Black
1 ea . Rubber Grommet
4 ea . Wall Plug
4 ea . Wall Fixing Screws
2 ea . Ceramic bracket
2 ea . Clevis Pin
u
FIREBO
X OUTLINE
C
ONT
ORNO DE LA CAMARA DE C
OMBUSTION
POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL
COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED
PIERCE TEMPLATE TO MARK
HOLE POSITION ON WALL X 4
CENTRE LINE
CONCEALED GAS INLET
ENTRADA DE GAS OCULTA
FIXING POINTS
Elite
CVF
FIXING POINTS
PUNTOS DE SUJECION
PERFORE LA PLANTILLA PARA MARCAR
LA POSICION DE LOS 4 TALADROS EN LA PARED
PUNTOS DE SUJECION
LINEA DE CENTRO
WALL MOUNTED VENT FREE FITTING TEMPLATE
PLANTILLA PARA LA INSTALACION DE CHIMENEAS
DE PARED SIN SALIDA DE HUMOS
IMPORTANT
THIS APPLIANCE IS TO BE WALL HUNG ONLY.
DO NOT RECESS OR INSET ANY PART OF THE APPLIANCE.
THIS TEMPLATE IS FOR THE MARKING OF FIXING POINTS ONLY.
DO NOT INSTALL THE APPLIANCE WITH THIS TEMPLATE IN PLACE.
IMPORTANTE
ESTE APARATO UNICAMENTE DEBE SER COLGADO EN UNA PARED.
NO EMPOTRE NINGUN ELEMENTO DE ESTE APARATO.
ESTA PLANTILLA SIRVE UNICAMENTE PARA MARCAR LOS PUNTOS DE FIJACION.
RETIRE LA PLANTILLA ANTES DE COLOCAR LE APARATO.
WARNING
CLEARANCES FROM COMBUSTIBLE MATERIALS
F860041/A
The following clearances must be maintained at all times.
Failure to do so may result in the risk of a fire.
For full information refer to the instruction manual
provided with the heater.
Note : Zero clearance from bottom of heater frame
required for hard combustible floors. Minimum 4”
clearance required to rugs or any fabric floor
coverings. REFER TO INSTRUCTION MANUAL
IMPORTANT : Fabrics, curtains and drapes are not
permited above the heater at any distance and within
20” of the heater sides. No combustible shelves of any
size are permitted above the heater.
Clearance to
combustible
sidewalls 4”
(both sides)
Clearance to combustible ceiling
32” measured from top of appliance
glass panel
Clearance in
front of
heater 20”
F860041/A
Deben mantenerse en todo momento los siguientes espacios
libres. El no hacerlo puede causar un riesgo de incendio.
Consulte el manual de instrucciones suministrado con este
aparato para obtener información completa.
Nota: No se requiere espacio libre desde el borde inferior del
marco del calentador en caso de pisos combustibles duros.
Se requiere un espacio mínimo de 4” entre el calentador y
cualquier alfombra, moqueta o revestimiento de suelo de
tela. CONSULTE EL MANUAL DE INSTRUCCIONES.
IMPORTANTE: No se permite la colocación de telas, cortinas y
similares por encima del calentador a cualquier distancia, ni a
una distancia de 20” de los laterales del calentador. No se
permiten estantes combustibles de cualquier tamaño por
encima del calentador.
Espacio hasta
paredeslaterales
combustibles
4” (ambos lados)
El espacio de 32” hasta un techo
combustible se mide desde el borde
superior del panel de vidrio del aparato
Espacio libre
delante del
calentador 20”
ADVERTENCIA
ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES
DO 005860/0 - ISSUE A
™
20-1/4”
(515mm)
1-1/8” (28mm)
9-3/16” (234mm)
APPLIANCE OUTLINE
C
ONT
ORNO DE LA AP
ARA
TO
FocalPointFires Single 24/07/08
DO 005860/0 Iss-B
Lennox P23 Elite CVF fitting template
Ref. Paul West - Focal Point Fires
Artwork Size: W605 x H960
5
4
10
Hardware
4
3
13