Page 52
Cleaning the Burner Assembly (if needed)
1 -
Turn off electrical and gas power supplies to furnace.
Remove upper and lower furnace access panels.
2 -
Disconnect the 2-pin plug from the gas valve.
3 - Remove the burner box cover (if equipped).
4 - Disconnect the gas supply line from the gas valve.
Remove gas valve/manifold assembly.
5 - Loosen clamps and remove combustion air intake
flexible connector (if equipped).
6 -
Mark and disconnect sensor wire from the sensor.
Disconnect plug from the ignitor at the burner box.
7 - Remove four screws which secure burner box
assembly to vest panel. Remove burner box from
the unit.
8 -
Use the soft brush attachment on a vacuum cleaner
to gently clean the face of the burners. Visually
inspect the inside of the burners and crossovers for
any blockage caused by foreign matter. Remove
any blockage.
9 -
Reinstall the burner box assembly using the existing
four screws. Make sure that the burners line up in
the center of the burner ports.
10 - Reconnect the sensor wire and reconnect the 2-pin
plug to the ignitor wiring harness.
11 -
Reinstall combustion air intake flexible connector (if
equipped), secure using existing clamps.
12 -
Reinstall the gas valve manifold assembly.
Reconnect the gas supply line to the gas valve.
Reinstall the burner box cover.
13 - Reconnect plug to gas valve.
14 - Replace the blower compartment access panel.
15 - Refer to instruction on verifying gas and electrical
connections when re-establishing supplies.
16 -
Follow lighting instructions to light and operate
furnace for 5 minutes to ensure that heat exchanger
is clean and dry and that furnace is operating
properly.
17 - Replace access panel.