Page 4
Specifications
General
Data
Model No. EL16XP1-018 EL16XP1-024 EL16XP1-030
EL16XP1-036
Nominal Tonnage
1.5
2
2.5
3
1
Sound Rating Number (dBA)
71
72
72
72
Connections
(sweat)
Liquid line (o.d.) - in.
3/8
3/8
3/8
3/8
Suction line (o.d.) - in.
3/4
3/4
3/4
7/8
Refrigerant
2
R-410A charge furnished
6 lbs. 6 oz.
6 lbs. 11 oz.
7 lbs. 10 oz.
8 lbs. 7 oz.
Outdoor
Coil
Net face area - sq. ft. Outer coil
24.5
18.7
18.7
22.2
Inner coil
- - -
18.0
18.0
21.5
Tube diameter - in.
5/16
5/16
5/16
5/16
No. of rows
1
2
2
2
Fins per inch
22
22
22
22
Outdoor
Fan
Diameter - in.
22
22
22
26
No. of blades
3
3
3
3
Motor hp
1/6
1/6
1/6
1/3
Cfm
2670
2575
2575
3700
Rpm
867
866
866
820
Watts
160
163
163
200
Shipping Data - lbs. 1 pkg.
213
211
211
214
ELECTRICAL DATA
Line voltage data - 60hz
208/230V-1ph
208/230V-1ph
208/230V-1ph
208/230V-1ph
3
Maximum overcurrent protection (amps)
20
20
25
35
4
Minimum circuit ampacity
12.2
13.6
16.4
20.9
Compressor
Rated load amps
9
10.1
12.3
14.7
Locked rotor amps
48
52
63
75
Power factor
0.98
0.98
0.96
0.99
Outdoor Fan Motor
Full load amps
1.0
1.0
1.0
2.6
Locked rotor amps
1.9
1.9
1.9
- - -
CONTROLS
iComfort
®
E30 Smart Wi-Fi Thermostat
15S63
•
•
•
•
Remote Outdoor Temperature Sensor
X2658
•
•
•
•
OPTIONAL ACCESSORIES - ORDER SEPARATELY
Compressor Crankcase Heater
93M04
•
•
•
Factory
•
Compressor Hard Start Kit
LG
88M91
•
•
•
•
Compressor Low Ambient Cut-Off
45F08
•
•
•
•
Freezestat
3/8 in. tubing
93G35
•
•
•
•
5/8 in. tubing
50A93
•
•
•
•
Indoor Blower Off Delay Relay
58M81
•
•
•
•
Loss of Charge Switch Kit
84M23
•
•
•
•
5
Low Ambient Kit
54M89
•
•
•
•
Mild Weather Kit
11B97
•
•
•
•
Monitor Kit - Service Light
76F53
•
•
•
•
Outdoor Thermostat Kit
Thermostat
10Z23
•
•
•
•
Mounting Box
31461
•
•
•
•
Refrigerant
Line Sets
L15-41-20
L15-41-30
L15-41-40
L15-41-50
•
•
•
6
Snow Guard
35-1/2 x 31 in. (Canada Only)
X8780
•
•
•
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Sound Rating Number rated in accordance with test conditions included in AHRI Standard 270.
2
additional refrigerant charge required.
3
HACR type breaker or fuse.
4
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
5
Crankcase Heater and Freezestat are recommended with Low Ambient Kit.
6
Add 11-1/2 inches (292 mm) to unit height.