background image

3

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Burner Orifi ce Sizes 

Elevation 0-4500 feet ( 0-1372 meters)

Model
Series

Natural

Gas

drill size 

(inches)

Propane

Gas

drill size (inches)

LMDVT-3328
LMDVR-3328

#45 (.082") 

*

39L6601 •

(.048") 

*

99K78 •

LMDV-3530

#44 (.086") 

*

60J8001 •

#55 (.052") 

*

19L5201 •

LMDV-4035

#37 (.104") 

*

24M1001 •

1/16" (.0625")

*

21L0101 •

* Standard size installed at factory
•  Part /Cat. Number

Table 7

Inlet Gas Supply Pressure 

(all models)

Fuel #

Minimum

Maximum

Natural Gas

5.0" WC

(1.24 kPa)

10.5" WC

(2.61 kPa)

Propane

11.0" WC

(2.74 kPa)

13.0" WC

(3.23 kPa)

Table 4

Burn-in Period

During the fi rst few fi res of this appliance there 
will be some odor due to the curing of the 
paint and burning off of lubricants used in the 
manufacturing process. 

Depending on your use, the burn-in period may 
take a few hours or a few days.  

KEEP YOUR HOUSE WELL VENTILATED 
DURING THE CURING PROCESS.  THE ODOR 
AND HAZE EMITTED DURING THE CURING 
PROCESS CAN BE QUITE NOTICEABLE AND 
MAY SET OFF A SMOKE DETECTOR.

If an optional blower is installed, Do not turn it 
on during the Burn-In period. 

A white fi lm may develop on the glass front 
during the fi rst few fi res as part of the curing 
process.  The glass should be kept clean during 
the fi rst two weeks of use to prevent the fi lm from 
baking on (making it very diffi cult to remove).  
See 

Cleaning Glass 

on 

Page 6

.

       WARNING 

Failure to comply with the instal-
lation and operating instructions 
provided in this document will 
result in an improperly installed 
and operating appliance, voiding 
its warranty.  Any change to this 
appliance and/or its operating 
controls is dangerous.  Improper 
installation or use of this appli-
ance can cause serious injury or 
death from fi re, burns, explosion 
or carbon monoxide poisoning

.

       WARNING 

Do not use these appliances if 
any part has been under water.  
Immediately call a qualifi ed, 
professional service technician 
to inspect the appliances and to 
replace any parts of the control 
system and any gas controls 
which have been under water.

          IMPORTANT

These appliances must not be 
connected to a chimney or fl ue 
serving a separate solid fuel 
burning appliance. 

       WARNING 

Do not attempt to alter or modify 
the construction of the appli-
ance or its components. Any 
modifi cation or alteration may 
void the warranty, certifi cation 
and listings of this unit.

These appliances and their individual shut-off 
valves 

must be disconnected

 from the gas 

supply piping system during any pressure 
testing of that system at pressures 

greater 

than

 1/2 psig (3.5 kPa)

.

These appliances must be isolated from the 
gas supply piping system (

by closing their 

individual manual shut-off valve

) during any 

pressure testing of the gas supply piping 
system at test pressures equal to or 

less than 

1/2 psig (3.5 kPa).

At the time of installation, it must be determined 
if the appliance needs to be derated. Contact 
your local gas supplier for deration requirements 
for your area.

Deration -

 At higher elevations, the amount of 

BTU fuel value delivered must be reduced by 
either using gas that has been derated by the gas 
company or by changing the burner orifi ce to a 
smaller size as regulated by the local authorities 
having jurisdiction and by the (USA) National 
Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest 
edition or, in Canada, the CAN1-B149.1 and .2 
codes - latest edition. 

Gas Pressure - 

Tables 4, 5 and 6

 show the appliances' gas 

pressure requirements.

Manifold Gas Supply Pressure

(millivolt models)

Fuel #

Low

High

Natural 

Gas

(Lo) 2.2" WC

(.55 kPa)

(Hi) 3.5" WC

(.87 kPa)

Propane

(Lo) 6.3" WC

(1.57 kPa)

(Hi) 10.0" WC

(2.49 kPa)

Table 5

Manifold Gas Supply Pressure 

(electronic models)

Fuel #

Fixed

Natural Gas

3.5" WC

(.87 kPa)

Propane

10.0" WC

(2.49 kPa)

Table 6

Test gauge connections are provided on the 
front of the millivolt gas control valve, identifi ed 
IN for the inlet and OUT for the manifold side 
(see 

Figures 4 or 5 

on 

Page 5 

).  A 1/8" NPT 

Test gauge connection is provided at the inlet 
and outlet (manifold) ports on the electronic gas 
control valve (see 

Figure 3

 on 

Page 5 

).

Orifi ce Sizes -  Sea Level to High Altitude
(All Models): 

These appliances are tested and 

approved for installations at elevations of 0-4500 
feet (0-1372 meters) above sea level using the 
standard burner orifice sizes (marked with an 
"*" in 

Table 7 

).  

     

WARNING

If the information in this 
manual is not followed 
exactly, a  fi re or explosion 
may result causing prop-
erty damage, personal 
injury or loss of life.

       WARNING 

Improper installation, adjust-
ment, alteration, service or 
maintenance can cause injury 
or property damage.  Refer to 
this manual.  For assistance or 
additional information consult 
a qualifi ed installer, service 
agency or the gas supplier.

Summary of Contents for DIRECT VENT MERIT LMDV-33 SERIES

Page 1: ...O NOT light any appliance DO NOT touch any electrical switches Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow your gas suppliers instructions I...

Page 2: ...ns Millivolt Page 17 Lighting Instructions Electronic Page 18 Maintenance Schedule Page 19 Troubleshooting Guide Millivolt Page 20 Troubleshooting Guide Electronic Page 20 Replacement Parts List Page...

Page 3: ...nents Any modification or alteration may void the warranty certification and listings of this unit Theseappliancesandtheirindividualshut off valves must be disconnected from the gas supply piping syst...

Page 4: ...down until it locks in place Figure 1 OPENING CONTROL COMPARTMENT DOOR Operation of millivolt and electronic gas con trol systems are different Before lighting and operatingyourappliancedetermineifyou...

Page 5: ...ons Electronic appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve 3 Keep the lower control compartment clean by vacuuming o...

Page 6: ...ed replacement use only the proper replacement logs from manufacturer see Pages 22 23 for ordering information Re Install Embers Logs and Vermiculite Carefully follow placement instructions on Pages 8...

Page 7: ...front of the appliance 4 Swing the bottom of the door out and raise it slightly to lift the top flange of the door frame away from the appliance Installing Glass Enclosure Panels see Figure 6 1 Visua...

Page 8: ...re 8 Logs should be placed in the order shown and per the following instructions WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested...

Page 9: ...VolcanicStoneandLogsintheorder shown here 1 through 6 and per the instructions onPage8 A E B C D Vermiculite Volcanic Stone Embers DO NOT PLACE EMBERS OVER GAS SLOTS 1 2 3 4 5 6 The2notchesonlogbottom...

Page 10: ...rrespond to photos InstalltheEmbers Vermiculite VolcanicStoneandLogsintheorder shownhere 1through6 andper theinstructionsonPage8 D C E A B 1 2 3 4 5 6 Vermiculite Volcanic Stone DONOTPLACEEMBERSOVERGA...

Page 11: ...hanorangebodythatdoes not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines If there is smoke or soot present first check the log set positioning t...

Page 12: ...position until the proper flame appearance is achieved 4 Leave the control knob off pilot on in the ON position and the burner OFF ON switch OFF remote switches if applicable 5 When satisfied that the...

Page 13: ...ctlytothe appliance on a pullout panel located within the control compartment TH TP TH TP Thermopile If any of the original wire as supplied must be replaced it must be replaced with Type AWM 105o C 1...

Page 14: ...d system may be operated with electronic and mil livoltsystemswitheithernaturalgasorpropanegas The RCL T comes complete with detailed operating instructions Remote Control Kit Deluxe Cat No Model No D...

Page 15: ...Doors Charcoal LMDV 4035 H0967 SPD40TI 40 Sq Pane Doors Textured Iron H0968 SPD40SP 40 Sq Pane Doors Satin Pewter H0969 SPD40AB 40 Sq Pane Doors Antique Brass Arch Design Arch Pane Design Square Desi...

Page 16: ...nce These kits can be retrofitted to previously installed appliances ref Form 750 166M Polished Brass Brushed Stainless Hood Kits Attractive hoods are available in two styles These hoods are designed...

Page 17: ...your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempted repair ma...

Page 18: ...been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCT...

Page 19: ...o many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service...

Page 20: ...witch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or remote control A Wall switch or wires defective Check wall switch and wi...

Page 21: ...ommon leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identify proper lead this check must be done with the valve control con nected and igniter powered NO Check t...

Page 22: ...93L32 1 Lennox Nameplate Logo 12L15 is sold separately Gas Controls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 12 Gas Valve SIT 43K07 1 88J53 1 13 Piezo Igniter 111061 1 111061 1 14...

Page 23: ...23 NOTE DIAGRAMS ILLUSTRATIONSNOTTOSCALE REPLACEMENT PARTS 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20 31 21 8 LMDV 4035 LMDVT 3328 LMDVR 3530...

Page 24: ...P N 875 028M REV C 06 2005 LENNOX reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult you...

Reviews: