background image

15

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Style View Doors -  

Style View Doors come in 4 beautiful styles. They are easy to install and will not require hardware to attach them to 
the standard glass door frame. The door includes heavy duty magnet door latches and functional twin-pane doors. 

(ref. Form # 775,169M)

Style View Doors - Arch Design Kits

Cat. No.

Model

Description

Model 
Series

H0858

AD35C

35” Arch Doors, Charcoal

LMDV-3530

H0859

AD35TI

35” Arch Doors, Textured Iron

H0860

AD35SP

35” Arch Doors, Satin Pewter

H0861

AD35AB

35” Arch Doors, Antique Brass

H0862

AD40C

40” Arch Doors, Charcoal

LMDV-4035

H0863

AD40TI

40” Arch Doors, Textured Iron

H0864

AD40SP

40” Arch Doors, Satin Pewter

H0865

AD40AB

40” Arch Doors, Antique Brass

Style View Doors - Arch Pane Design Kits

H0930

APD35C

35” Arch Pane Doors, Charcoal

LMDV-3530

H0931

APD35TI

35” Arch Pane Doors, Textured Iron

H0932

APD35SP

35” Arch Pane Doors, Satin Pewter

H0933

APD35AB

35” Arch Pane Doors, Antique Brass

H0934

APD40C

40” Arch Pane Doors, Charcoal

LMDV-4035

H0935

APD40TI

40” Arch Pane Doors, Textured Iron

H0936

APD40SP

40” Arch Pane Doors, Satin Pewter

H0937

APD40AB

40” Arch Pane Doors, Antique Brass

Style View Doors - Square Design Kits

H0946

SD35C

35” Sq. Doors, Charcoal

LMDV-3530

H0947

SD35TI

35” Sq. Doors, Textured Iron

H0948

SD35SP

35” Sq. Doors, Satin Pewter

H0949

SD35AB

35” Sq. Doors, Antique Brass

H0950

SD40C

40” Sq. Doors, Charcoal

LMDV-4035

H0951

SD40TI

40” Sq. Doors, Textured Iron

H0952

SD40SP

40” Sq. Doors, Satin Pewter

H0953

SD40AB

40” Sq. Doors, Antique Brass

Style View Doors - Square Pane Design Kits

H0962

SPD35C

35” Sq. Pane Doors, Charcoal

LMDV-3530

H0963

SPD35TI

35” Sq. Pane Doors, Textured Iron

H0964

SPD35SP

35” Sq. Pane Doors, Satin Pewter

H0965

SPD35AB

35” Sq. Pane Doors, Antique Brass

H0966

SPD40C

40” Sq. Pane Doors, Charcoal

LMDV-4035

H0967

SPD40TI

40” Sq. Pane Doors, Textured Iron

H0968

SPD40SP

40” Sq. Pane Doors, Satin Pewter

H0969

SPD40AB

40” Sq. Pane Doors, Antique Brass

Arch Design

Arch Pane Design

Square Design

Square Pane Design

Forced Air Kit

The FBK-100 blower provides constant velocity forced 
air circulation. The FBK-200 assembly with variable 
speed, wall-mountable switch provides variable speed 
forced air circulation. The FBK-250  assembly with 
variable speed unit-mountable switch, also provides 
variable speed forced air circulation.

Forced Air Blower Kits

Cat. 

No.

Model No.

Description

80L84

FBK-100

Blower, Standard
(single speed)

80L85

FBK-200

Blower, Variable Speed 
(w/wall-mounted switch)

80L86

FBK-250

Blower, Variable Speed 
(w/unit-mounted switch)

94L89

FBK-100-36

Blower, Standard, 36 Pack

94L90

FBK-200-36

Blower Kit - Variable Speed 
with Wall Switch 36 Pack

H0543

FBK-250-36

Blower Kit - Variable Speed 
with Thermo Snap Switch 
36 Pack

(ref. Form # 750,028M & 750,029M)

Variable Speed Wall Switch

Provides variable speed control if optional blower 
kit is purchased.

Variable Speed Wall Switch

Cat. No.

Model No.

Description

045571H

VSWS

Rocker Switch Kit

ACCESSORY COMPONENTS (CONTINUED)

Bag of Glowing Embers
Bag of Volcanic Stone

Replacement ember materials or volcanic stone are 
available for use with these appliances. Order kits as 
part of the periodic maintenance of the appliance. 

Decorative Firebox Accessories

(all models)

Cat. No.

Model No.

Description

88L53

FGE

Bag of Glowing Embers
(1 oz. rockwool)

80L42

FDVS

Bag of Decorative 
Volcanic Stone

(FDVS ref. Form #750,010M)

Brickaded Wall Liner Kits

Cat. No.

Model No.

Description

H0912

MBLK-33T

Brick Liner Kit, Top Vent,
LMDVT-3328

H0918

MBLK-33R

Brick Liner Kit, Rear Vent,
LMDVR-3328

H0913

MBLK-35

Brick Liner Kit, Top/Rear,
LMDV-3530

H0914

MBLK-40

Brick Liner Kit, Top/Rear,
LMDV-4035

Brickaded Panel Liner Kit

The brickaded liner kits include ceramic panels as 
shown here.  The panels have brick-like features in relief.

(ref. Form # 750,160M)

Summary of Contents for DIRECT VENT MERIT LMDV-33 SERIES

Page 1: ...O NOT light any appliance DO NOT touch any electrical switches Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow your gas suppliers instructions I...

Page 2: ...ns Millivolt Page 17 Lighting Instructions Electronic Page 18 Maintenance Schedule Page 19 Troubleshooting Guide Millivolt Page 20 Troubleshooting Guide Electronic Page 20 Replacement Parts List Page...

Page 3: ...nents Any modification or alteration may void the warranty certification and listings of this unit Theseappliancesandtheirindividualshut off valves must be disconnected from the gas supply piping syst...

Page 4: ...down until it locks in place Figure 1 OPENING CONTROL COMPARTMENT DOOR Operation of millivolt and electronic gas con trol systems are different Before lighting and operatingyourappliancedetermineifyou...

Page 5: ...ons Electronic appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve 3 Keep the lower control compartment clean by vacuuming o...

Page 6: ...ed replacement use only the proper replacement logs from manufacturer see Pages 22 23 for ordering information Re Install Embers Logs and Vermiculite Carefully follow placement instructions on Pages 8...

Page 7: ...front of the appliance 4 Swing the bottom of the door out and raise it slightly to lift the top flange of the door frame away from the appliance Installing Glass Enclosure Panels see Figure 6 1 Visua...

Page 8: ...re 8 Logs should be placed in the order shown and per the following instructions WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested...

Page 9: ...VolcanicStoneandLogsintheorder shown here 1 through 6 and per the instructions onPage8 A E B C D Vermiculite Volcanic Stone Embers DO NOT PLACE EMBERS OVER GAS SLOTS 1 2 3 4 5 6 The2notchesonlogbottom...

Page 10: ...rrespond to photos InstalltheEmbers Vermiculite VolcanicStoneandLogsintheorder shownhere 1through6 andper theinstructionsonPage8 D C E A B 1 2 3 4 5 6 Vermiculite Volcanic Stone DONOTPLACEEMBERSOVERGA...

Page 11: ...hanorangebodythatdoes not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines If there is smoke or soot present first check the log set positioning t...

Page 12: ...position until the proper flame appearance is achieved 4 Leave the control knob off pilot on in the ON position and the burner OFF ON switch OFF remote switches if applicable 5 When satisfied that the...

Page 13: ...ctlytothe appliance on a pullout panel located within the control compartment TH TP TH TP Thermopile If any of the original wire as supplied must be replaced it must be replaced with Type AWM 105o C 1...

Page 14: ...d system may be operated with electronic and mil livoltsystemswitheithernaturalgasorpropanegas The RCL T comes complete with detailed operating instructions Remote Control Kit Deluxe Cat No Model No D...

Page 15: ...Doors Charcoal LMDV 4035 H0967 SPD40TI 40 Sq Pane Doors Textured Iron H0968 SPD40SP 40 Sq Pane Doors Satin Pewter H0969 SPD40AB 40 Sq Pane Doors Antique Brass Arch Design Arch Pane Design Square Desi...

Page 16: ...nce These kits can be retrofitted to previously installed appliances ref Form 750 166M Polished Brass Brushed Stainless Hood Kits Attractive hoods are available in two styles These hoods are designed...

Page 17: ...your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempted repair ma...

Page 18: ...been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCT...

Page 19: ...o many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service...

Page 20: ...witch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or remote control A Wall switch or wires defective Check wall switch and wi...

Page 21: ...ommon leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identify proper lead this check must be done with the valve control con nected and igniter powered NO Check t...

Page 22: ...93L32 1 Lennox Nameplate Logo 12L15 is sold separately Gas Controls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 12 Gas Valve SIT 43K07 1 88J53 1 13 Piezo Igniter 111061 1 111061 1 14...

Page 23: ...23 NOTE DIAGRAMS ILLUSTRATIONSNOTTOSCALE REPLACEMENT PARTS 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20 31 21 8 LMDV 4035 LMDVT 3328 LMDVR 3530...

Page 24: ...P N 875 028M REV C 06 2005 LENNOX reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult you...