background image

4

m /h

3

(1)Inlet air temperature: 27ºC BS / 19ºC BH

Water temperature: 7/12º C

(2)Inlet air temperature: 20ºC BS

Water temperature: 50º C

(3)Inlet air temperature: 20ºC BS

Water temperature: 70/60º C

(4)Fan high speed. 

Power supply 230V-1ph-50Hz 230V-1ph-50Hz

(*)Sound level has been tested at a distance of 2 m from the unit, at standard conditions

6750

8450

kPa(1)

W(1)

l

5190

6600

1160

1450

24

28

 CWC 070-2P

CWC 090-2P

W(1)

l/h(1)

42

54

9150

10600

kPa(2)

1160

1450

24

28

W(2)

l/h(2)

0.18

0.2

A

A(4)

0.8

0.9

4

4

17.4

17.4

W(4)

KW

14930

17300

kPa(3)

1280

1490

28

29

1400 / 1020

1650 / 1200

W(3)

l/h(3)

F 3/4'' G

F 3/4'' G

dB(A)(*)

51/42

47/41

Kg

298x1175x575

5

5

Kg

43

45

HxLxW(mm)

HxLxW(mm)

48x1320x720

48x1320x720

298x1175x575

SPECIFICATIONS

UNIT

Total cooling capacity

Sensible cooling capacity

Chilled water flow rate

Water content

Hot water flow rate

Air flow (max. / min)

Fan power consumption

Running current

Electric heater power consumption

Running current with electric heater

2 PIPES SYSTEM

Hot water flowrate

Hot water pressure drop

Pipe connections

Sound level (Lp)

Diffuser dimensions

Cassette dimensions

Diffuser weight

Cassette weight

Chilled water pressure drop

Hot water pressure drop

Total heating capacity

Total heating capacity

(*)Sound level has been tested at a distance of 2 m from the unit, at standard conditions

6750

8450

kPa(1)

W(1)

l

5190

6600

1160

1450

24

28

 CWC 070-2P

CWC 090-2P

W(1)

l/h(1)

42

54

9150

10600

kPa(2)

1160

1450

24

28

W(2)

l/h(2)

0.18

0.2

A

A(4)

0.8

0.9

4

4

17.4

17.4

W(4)

KW

14930

17300

kPa(3)

1280

1490

28

29

1400 / 1020

1650 / 1200

W(3)

l/h(3)

F 3/4'' G

F 3/4'' G

dB(A)(*)

51/42

47/41

Kg

298x1175x575

5

5

Kg

43

45

HxLxW(mm)

HxLxW(mm)

48x1320x720

48x1320x720

298x1175x575

SPECIFICATIONS

UNIT

Total cooling capacity

Sensible cooling capacity

Chilled water flow rate

Water content

Hot water flow rate

Air flow (max. / min)

Fan power consumption

Running current

Electric heater power consumption

Running current with electric heater

2 PIPES SYSTEM

Hot water flowrate

Hot water pressure drop

Pipe connections

Sound level (Lp)

Diffuser dimensions

Cassette dimensions

Diffuser weight

Cassette weight

Chilled water pressure drop

Hot water pressure drop

Total heating capacity

Total heating capacity

Summary of Contents for CWC 070-2P

Page 1: ...WATER CASSETTE INSTALLATION OPERATION MAINTENANCE MANUAL...

Page 2: ...ternational organisation with world wide distribution takes pride in supplying you with this product CONTENTS PRODUCT RANGE GENERAL INFORMATION SPECIFICATION COOLING CAPACITIES HEATING CAPACITIES WATE...

Page 3: ...WC 070 4P CWC 090 4P COOLING HEATING 8450 5800 7050 10600 6450 LENNOX Cassette unit Difusser Installation manual Hanging bracket insulation Screws and washers Setting up template Packed separately PRO...

Page 4: ...e which is removed by means of a condensate pump Made in decorative plastic with a smooth finish Internal insulation prevents condensation from forming Four louvres ensure air distribution A polypropy...

Page 5: ...water pressure drop Pipe connections Sound level Lp Diffuser dimensions Cassette dimensions Diffuser weight Cassette weight Chilled water pressure drop Hot water pressure drop Total heating capacity T...

Page 6: ...tric heater power consumption Running current with electric heater 4 PIPES SYSTEM Pipe connections Sound level Lp Diffuser dimensions Cassette dimensions Diffuser weight Cassette weight Chilled water...

Page 7: ...ing capacity 6600 W To estimate the water flow use the formula Qw Pt x 0 86 Qw Water flow l h T Pt Total cooling capacity W T Inlet water temperature outlet water temperature C For the example given Q...

Page 8: ...speed fan For a different speed the given values must be multiplied by the following correction factors HEATING CAPACITY EXAMPLE For the unit CWC 090 2P with entering water temperature entering air te...

Page 9: ...46 9 11 14 16 1160 24 18 1450 33 28 CWC 070 4P CWC 090 4P CWC 090 4P CWC 070 4P 400 900 500 1000 1200 700 600 800 24 27 COOL WATER HOT WATER 7 9 11 21 15 16 18 PRESSURE DROP Kpa 1100 1300 1400 1500 16...

Page 10: ...IFFUSER PANEL 298 37 152 197 Outlet cool water connection 3 4 G Inlet cool water connection 3 4 G 75 63 24 Drain tube 16 mm O D Condensate pump flexible hose 10 mm I D 15 mm O D Electrical cable entry...

Page 11: ...t is necessary to remove any water that accumulates in the drip tray 1 The unit should be positioned centrally within the room The ceiling must be horizontal to ensure that the unit is on level The un...

Page 12: ...The water connections should be positioned before that the unit is installed 6 When lifting the cassette into position care should be taken not to lift the unit by the drip tray water connection drai...

Page 13: ...al power and check that the fan has stopped 1 3 2 3 CONTROL PANEL Removing the corresponding plate cover screws gives access to the electrical board and terminal plate as indicated on the drawing For...

Page 14: ...ected with the power supply wires it depends on versions Check that the position in which the diffuser is mounted is the right one 1 Release the air intake grille 2 The diffuser panel can then be prov...

Page 15: ...a risk of damaging the unit through dust contamination ACCESS TO ELECTRICAL COMPONENTS Fig 2 3 1 Stop the unit 2 Open the air intake grille on the unit Open the grille by way of two hand triggers whi...

Page 16: ...trol as well the louvres may be set to move continuously sweep mode For more information see the remote control manual DIRECCIONAMIENTO DE AIRE DRIP TRAY VOLUTE MAINTENANCE 1 2 Louvre position for cor...

Page 17: ...xible polyester type or corrugate aluminium externally covered with anti condensate material The duct length can be calculated by taking into account the pressure drop through the unit using the follo...

Page 18: ...ay be faulty 3 Condensate overflowing Check drip tray for blockage and condensate drains away Check unit is level Check condensate pump is working Check service drain pipework Install the auxiliary dr...