CLEARANCE TO COMBUSTIBLES

The following clearances meet the minimum requirements for a safe 

installation:

Side wall: 

17” (324 mm) measured from the fireplace side.

Ceiling:

  6’ 8”  (2,032 mm) measured from the base of the fireplace.

Fireplace enclosure:

 

Bottom

:  0”

Side:

   0”

Back:

   0”

Top:

  Do  not  fill  the  space  above  the  fireplace  with  any  material 

(Except the wood framing.  See 

Page 8, Figure 7

).

Chimney:

  2” (50 mm)

Mantel: 

45”  (1143 mm) measured from the base of the fireplace.

Brentwood™ Replacement Parts

Description

Cat./Part No.

Baffle Refractory (2 Pieces)

PR-ISO2205

Back Refractory

 PR-SR2203

Right Side Refractory

PR-SR2204D

Left Side Refractory

PR-SR2204G

Bottom Refractory

PR-SR2201

Front Refractory, Right Side - Ash Lip

PR-SR2202D

Front Refractory, Left Side - Ash Lip

PR-SR2202G

Door Handle

PR-SR1787

Ceramic Glass Panel

PR-SR2222-1

Secondary Air Tube

PR-SR2271

Cast-iron Log Retainer Supports - Grate (2)

PR-SR2324

Cast Iron Log Retainer Bar (w/Lennox Logo)

PR-SR2323

Touch-up Paint, Aerosol, Black Metallic SBMB6309

90L73

Louvers, Upper & Lower 

PR-SR2218-1

Snap Disc, Blower 

VTU

Bracket, Secondary Air Tube 

SR2214

Hinge Assembly, Fireplace & Door 

PR-SR2395UL

Handle, Door Rod

SR2395

Gasket, Door, 73” (5/8” dia.)

SR1823G

Gasket, Glass, 69” (5/16” dia.)

SR1823H

Door Handle Brass Cap

POIGNE002

Touch-up Paint, Black

90L73

REPLACEMENT PARTS LIST

SPECIFICATIONS

Cat. No.

Model

H4825

Brentwood SP

Product Reference Information

Weight

385 lbs 

Height

36”

Width

36”

Depth

24-1/2”

Firebox W x H x D - measured in front

22” x 11-3/4” x 12”

Chimney weight ASHT (6” dia)

6.25 lb/ft.

Chimney weight AC (6” dia)

3.25 lb/ft.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

22

Summary of Contents for BRENTWOOD SP

Page 1: ...LATION AND OPERATION INSTRUCTIONS Listed to standards ULC S610 UL 127 Report No 3011202 EPA Cert No 537 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNINGS Hot Do not touch The glass and surfaces...

Page 2: ...ength to be blown in front of an open flame when the window is opened Keepanycombustiblefurniture materials or decorative pillows at least 48 1219 mm from the front fireplace opening WARNING Nevermodi...

Page 3: ...el Brentwood SP 6 diameterchimney model ASHT S 2100 HT6000 HT6103 orACmanufacturedbySe curity Chimneys International only including Chimney lengths Elbows where necessary Associated components as per...

Page 4: ...factors including chimney length and the moisture content of the wood For instance a long chimney will necessitate closing the damper more To obtain the proper combustion closethedampercompletely then...

Page 5: ...ntenance combined with proper operation will prevent chimneyfires Keepyourchimneyclean Donot allow more than 1 16 1 6 mm creosote build upinyourchimney Theamountofcreosotewill depend on variables such...

Page 6: ...tory If the fit is still not perfect you can adjust the door using the hinge screws Figure 3 Figure 4 DOOR ADJUSTMENT The door may need to be adjusted to be completely airtight The gaskets air tightne...

Page 7: ...dealer in the following dimensions Figure 5 FIREPLACE INSTALLATION Locating The Brentwood A The best location to install your fireplace is determined by consider ing the location of windows doors and...

Page 8: ...e fireplace and wherever cold air could enter the room with noncombustible material Also the outside air inlet duct should be wrapped with noncombustible in sulation to minimize the formation of conde...

Page 9: ...Mantel The mantel must be installed at least 45 1143 mm above the base of the fireplace Figure 9 Figure 9 Figure 10 Roof Support Attic Radiation Shield Firestop 7 Feet Min 1 2 Plywood 2 x 4 Drywall No...

Page 10: ...The fireplace facade can be covered with non combustible material Figure 14 For safe installation the gravity kit must meet the following requirements Minimum height 68 1 727 mm Maximum length See Fig...

Page 11: ...Facing 13 x 13 10 Max 10 Max Maintain at least 6 1 2 160mm clearancefrom the outlet grill framing to a combustible ceiling side wall or mantel Outlet Grill Outlet Grill WARNING The outlet grills shoul...

Page 12: ...ome this problem we strongly recommend that you install an outside air assembly Check with local authorities having jurisdiction in your area it may be mandatory Note Should you decide not to install...

Page 13: ...eplace Connection Plastic Cover Insulation Flexible Pipe Fireplace OUTSIDE AIR CONNECTION TO THE FIREPLACE Figure 16 THE CHIMNEY system Chimney Installation Notes 1 Alwaysinstallaninteriorchimneyasitw...

Page 14: ...nd seal the joint between the roof and the flashing with roofing pitch see Figures 21 22 For sloping roofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashin...

Page 15: ...the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below install a firestop See...

Page 16: ...A 4 13 16 122 mm 6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm...

Page 17: ...n the home s thermal barrier RSM and RSMI30 RSMI45 Canada Only Chimney Model Angle Hole Size ASHT HT6103 6 dia Canada only 30 283 mm x 781 mm 11 1 8 x 30 3 4 45 283 mm x 518 mm 11 1 8 x 20 3 8 S 2100...

Page 18: ...PPORTED CHIMNEY OffsetSupport RoofSupport ASHT HT6103 6 dia 28feet 8 54m 29feet 8 84 m S 2100 HT6000 6 dia 18feet 5 49m 20feet 6 1 m AC 6 dia 40feet 12 19m 50feet 15 20 m Table 6 CHIMNEY CHASE AND MUL...

Page 19: ...er the masonry chimney 2 In the middle of the oval drill a hole in the masonry chimney at 30 3 Increase the size of the hole until a or 30 TUBINOX liner elbow can be easily slipped through 4 Slide the...

Page 20: ...SS 6 diameter with adaptor for installation in a masonry chimney Secure Temp ASHT 1 High Temp Insulated Stainless Steel Chimney 6 I D 8 O D Double Wall Stainl Steel Listed to CAN UCL S604 UL 103HT De...

Page 21: ...f Flashing FB H0496 Storm collar ACFC H0500 Misc Telescopic attic radiation shield ACRST H0498 Firestop ACBF H0485 Radiation Shield ACRS H0486 Attic Radiation Shield ACRSA H0487 Insulated Wall Radiati...

Page 22: ...PR SR2202D Front Refractory Left Side Ash Lip PR SR2202G Door Handle PR SR1787 Ceramic Glass Panel PR SR2222 1 Secondary Air Tube PR SR2271 Cast iron Log Retainer Supports Grate 2 PR SR2324 Cast Iron...

Page 23: ...or repair components will be shipped F O B the nearest LHP factory QUALIFICATIONS TO THE WARRANTY The complete fireplace Warranty outlined above is further subject to the following qualifications 1 T...

Page 24: ...arth Products dealer please call 1 800 9 LENNOX Replacement parts See Page 22 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered...

Reviews: