background image

(AC) Air-Cooled Chimney System*

 6” I.D. & 11” O.D. Air Cooled, Stainl. Steel inner & zinc coated steel exterior

AC Starter Adaptors

One of the following adaptors is required 

if installing an AC chimney system

* AC Chimney is NOT recommended at elevations above 4,000 feet or in cold climates 

(climates where temperatures will fall below 32° F / 0° C). 

Description

Cat./Part No.

Starter Section (adaptor), 6”, AC, AC6SB

H3779

Starter 30º Elbow, 6” AC, AC6SB30

H3780

The following outside air kit is required if installing an AC chimney system

Chimney Outside Air Kit (flex, insulation, outside register 

and coupling), ACZI

H1967

Lengths & Misc. Chimney Components 

12” Length, 6” Dia. x 12” Long, AC6L12

H0472

18” Length, 6” Dia. x 12” Long, AC6L18

H0473

36” Length, 6” Dia. x 36” Long, AC6L36

H0474

48” Length, 6” Dia. x 48” Long, AC6L48

H0475

15º Elbow, 6” Dia., AC6E15

H0476

30º Elbow, 6” Dia., AC6E30

H0477

Rain Termination Cap, 6” Dia., AC6CPR

H0478

Spark Arrester Screen (universal spark arrester band), PE

PE

Wall Band, XBM

XBM

Supports

Offset Support, SO

SO

Support Section, AC6SL

H0481

Roof Support, ST

ST

Roof Brace, BS2

BS2

Roof Flashings

Flat Roof Flashing, ACF

H0494

1/12 - 7/12 (5º - 30º), AC Adj. Roof Flashing, FA

H0495

8/12 - 12/12 (30º - 45º), AC Adj. Roof Flashing, FB

H0496

Storm collar, ACFC

H0500

Misc.

Telescopic attic radiation shield, ACRST 

H0498

Firestop, ACBF 

H0485

Radiation Shield, ACRS 

H0486

Attic Radiation Shield, ACRSA 

H0487

Insulated Wall Radiation Shield, 30º, ACRSMI30 

H0489

TUBINOX LL Chimney  Lining System 

Rigid Stainless Steel Liner For Relining A Masonry Chimney, 6” Diameter 

Listed to ULC-S635M, UL-1777 & ULC-S640M at 2100º F

Description

Cat./Part No.

6” Length, 6” Dia., 6LL6

6LL6

12” Length, 6” Dia., 6LL12

6LL12

24” Length, 6” Dia., 6LL24

6LL24

36” Length, 6” Dia., 6LL36

6LL36

48” Length, 6” Dia., 6LL48

6LL48

Adjustable Length (7” to 11”), 6” Dia., 6L7A

6L7A

Split Base Tee, 6” Dia., 6LT

6LT

Tee Cap, 6” Dia., 6TCS

6TCS

Twist Lock Tee Cap, 6” Dia., 6LTC

6LTC

Elbow 30º, 6” Dia., 6LE30

6LE30

Elbow 45º, 6” Dia., 6LE45

6LE45

Elbow 90º, 6” Dia., 6LE90

6LE90

Rain Termination Cap (regular), 6” Dia., 6LCS

6LCS

Rain Termination Cap (deluxe), 6” Dia., 6LCC

6LCC

Spark Arrester Screen (universal spark arrester band), PE

PE

Supports

Top Support, 6LST

6LST

Support Assembly, 6LSA

6LSA

Interior Support, 6LSB

6LSB

Adaptor Flexible Pipe (male), 6LAAM

6LAAM

Adaptor Flexible Pipe (female), 6LAAF

6LAAF

Stainless Steel Flex - five (5) feet Long, 6LLFLEX

6LLFLEX

Adjustable Insulated Wall Radiation Shield 6” - 12”, 6LRSMI

6LRSMI

Adaptors to Masonry Chimney

Masonry Chimney Adaptor, 30º, BISUMA30 
(for use with TUBINOX liner)

BISUMA30

CHIMNEY - PARTS AND COMPONENTS LISTS

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

21

Summary of Contents for BRENTWOOD SP

Page 1: ...LATION AND OPERATION INSTRUCTIONS Listed to standards ULC S610 UL 127 Report No 3011202 EPA Cert No 537 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNINGS Hot Do not touch The glass and surfaces...

Page 2: ...ength to be blown in front of an open flame when the window is opened Keepanycombustiblefurniture materials or decorative pillows at least 48 1219 mm from the front fireplace opening WARNING Nevermodi...

Page 3: ...el Brentwood SP 6 diameterchimney model ASHT S 2100 HT6000 HT6103 orACmanufacturedbySe curity Chimneys International only including Chimney lengths Elbows where necessary Associated components as per...

Page 4: ...factors including chimney length and the moisture content of the wood For instance a long chimney will necessitate closing the damper more To obtain the proper combustion closethedampercompletely then...

Page 5: ...ntenance combined with proper operation will prevent chimneyfires Keepyourchimneyclean Donot allow more than 1 16 1 6 mm creosote build upinyourchimney Theamountofcreosotewill depend on variables such...

Page 6: ...tory If the fit is still not perfect you can adjust the door using the hinge screws Figure 3 Figure 4 DOOR ADJUSTMENT The door may need to be adjusted to be completely airtight The gaskets air tightne...

Page 7: ...dealer in the following dimensions Figure 5 FIREPLACE INSTALLATION Locating The Brentwood A The best location to install your fireplace is determined by consider ing the location of windows doors and...

Page 8: ...e fireplace and wherever cold air could enter the room with noncombustible material Also the outside air inlet duct should be wrapped with noncombustible in sulation to minimize the formation of conde...

Page 9: ...Mantel The mantel must be installed at least 45 1143 mm above the base of the fireplace Figure 9 Figure 9 Figure 10 Roof Support Attic Radiation Shield Firestop 7 Feet Min 1 2 Plywood 2 x 4 Drywall No...

Page 10: ...The fireplace facade can be covered with non combustible material Figure 14 For safe installation the gravity kit must meet the following requirements Minimum height 68 1 727 mm Maximum length See Fig...

Page 11: ...Facing 13 x 13 10 Max 10 Max Maintain at least 6 1 2 160mm clearancefrom the outlet grill framing to a combustible ceiling side wall or mantel Outlet Grill Outlet Grill WARNING The outlet grills shoul...

Page 12: ...ome this problem we strongly recommend that you install an outside air assembly Check with local authorities having jurisdiction in your area it may be mandatory Note Should you decide not to install...

Page 13: ...eplace Connection Plastic Cover Insulation Flexible Pipe Fireplace OUTSIDE AIR CONNECTION TO THE FIREPLACE Figure 16 THE CHIMNEY system Chimney Installation Notes 1 Alwaysinstallaninteriorchimneyasitw...

Page 14: ...nd seal the joint between the roof and the flashing with roofing pitch see Figures 21 22 For sloping roofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashin...

Page 15: ...the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below install a firestop See...

Page 16: ...A 4 13 16 122 mm 6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm...

Page 17: ...n the home s thermal barrier RSM and RSMI30 RSMI45 Canada Only Chimney Model Angle Hole Size ASHT HT6103 6 dia Canada only 30 283 mm x 781 mm 11 1 8 x 30 3 4 45 283 mm x 518 mm 11 1 8 x 20 3 8 S 2100...

Page 18: ...PPORTED CHIMNEY OffsetSupport RoofSupport ASHT HT6103 6 dia 28feet 8 54m 29feet 8 84 m S 2100 HT6000 6 dia 18feet 5 49m 20feet 6 1 m AC 6 dia 40feet 12 19m 50feet 15 20 m Table 6 CHIMNEY CHASE AND MUL...

Page 19: ...er the masonry chimney 2 In the middle of the oval drill a hole in the masonry chimney at 30 3 Increase the size of the hole until a or 30 TUBINOX liner elbow can be easily slipped through 4 Slide the...

Page 20: ...SS 6 diameter with adaptor for installation in a masonry chimney Secure Temp ASHT 1 High Temp Insulated Stainless Steel Chimney 6 I D 8 O D Double Wall Stainl Steel Listed to CAN UCL S604 UL 103HT De...

Page 21: ...f Flashing FB H0496 Storm collar ACFC H0500 Misc Telescopic attic radiation shield ACRST H0498 Firestop ACBF H0485 Radiation Shield ACRS H0486 Attic Radiation Shield ACRSA H0487 Insulated Wall Radiati...

Page 22: ...PR SR2202D Front Refractory Left Side Ash Lip PR SR2202G Door Handle PR SR1787 Ceramic Glass Panel PR SR2222 1 Secondary Air Tube PR SR2271 Cast iron Log Retainer Supports Grate 2 PR SR2324 Cast Iron...

Page 23: ...or repair components will be shipped F O B the nearest LHP factory QUALIFICATIONS TO THE WARRANTY The complete fireplace Warranty outlined above is further subject to the following qualifications 1 T...

Page 24: ...arth Products dealer please call 1 800 9 LENNOX Replacement parts See Page 22 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered...

Reviews: