507581-05
Page 55 of 62
Issue 2220
Unit Start-Up
FOR YOUR SAFETY READ BEFORE OPERATING
Do not use this furnace if any part has been underwater.
A flood-damaged furnace is extremely dangerous.
Attempts to use the furnace can result in fire or explosion.
Immediately call a qualified service technician to inspect
the furnace and to replace all gas controls, control
system parts, and electrical parts that have been wet or
to replace the furnace, if deemed necessary.
WARNING
Danger of explosion. Can cause injury or
product or property damage. Should the
gas supply fail to shut off or if overheating
occurs, shut off the gas valve to the
furnace before shutting off the electrical
blower deck, before performing any
service procedure.
WARNING
Before attempting to perform any service or
maintenance, turn the electrical power to unit OFF at
disconnect switch.
CAUTION
BEFORE LIGHTING
the unit, smell all around the furnace
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
The gas valve on the unit is equipped with a gas control
switch (lever). Use only your hand to move switch. Never
use tools. If the switch will not move by hand, do not try to
repair it. Force or attempted repair may result in a fire or
explosion.
Placing the Furnace into Operation:
This furnace is equipped with an automatic hot surface
ignition system. Do not attempt to manually light burners
on this furnace. Each time the thermostat calls for heat, the
burners will automatically light. The ignitor does not get hot
when there is no call for heat on these units.
Gas Valve Operation
1.
STOP!
Read the safety information at the beginning
of this section.
2. Set the thermostat to the lowest setting.
Allowable Heating Speeds
Model
Low Fire Heating Speeds
High Fire Heating Speeds
Red
Yellow
Blue
Brown
Black
Red
Yellow
Blue
Brown
Black
030
Allowed
Factory
Setting
Allowed
Not
Allowed
Not
Allowed
Not
Allowed
Allowed
Factory
Setting
Allowed
Allowed
045
Allowed
Factory
Setting
Not
Allowed
Not
Allowed
Not
Allowed
Not
Allowed
Allowed
Factory
Setting
Allowed
Allowed
070
Allowed
Factory
Setting
Not
Allowed
Not
Allowed
Not
Allowed
Not
Allowed
Not
Allowed
Factory
Setting
Allowed
Allowed
090
Allowed
Factory
Setting
Not
Allowed
Not
Allowed
Not
Allowed
Not
Allowed
Not
Allowed
Allowed
Factory
Setting
Allowed
110
Factory
Setting
Not
Allowed
Not
Allowed
Not
Allowed
Not
Allowed
Not
Allowed
Allowed
Allowed
Factory
Setting
Allowed
Table 15.
Allowable Circulation Speeds
Model
Red
Yellow
Blue
Brown
Black
030
Allowed
Factory Setting
Not Allowed
Not Allowed
Not Allowed
045
Allowed
Factory Setting
Not Allowed
Not Allowed
Not Allowed
070
Allowed
Factory Setting
Not Allowed
Not Allowed
Not Allowed
090
Allowed
Factory Setting
Not Allowed
Not Allowed
Not Allowed
110
Factory Setting
Allowed
Not Allowed
Not Allowed
Not Allowed
Table 16.