background image

20

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

REPLACEMENT PARTS - SCANDIUM™

1

2

7

5

6

8

9a

Replacement Parts

Item #

Cat.No.

Description

1

H6057

Glass door assembly

2

H6060

Catalyst

3

H6061

Pilot assembly, Natural Gas

4

H6999

Pilot assembly, Propane Gas

5

H6058

Burner Assembly, Natural Gas

6

H7012

Burner Assembly, Propane Gas

7

H6062

Catalyst Gasket

8

H7037

3 Pc . Frame Assembly

9a

H7002

Ball Knob

9b

H7041

Knob Spindle

10

H7006

Hardware Kit 

u

11

H6068

Decorative Glass Facia

12

H7321

Fitting Template

Optional Parts

13

93L32

FFGC   Flex Gas Line Kit

9b

11

12

Hardware kits consists of the following:

 

6 ea . No .8 x 5/16 Screw Pozi Pan Head

 

6 ea . M6 x 12 Screw Pozi Pan Head BZP

 

6 ea . M4 x 12 Screw Pozi Pan Head Black

 

1 ea . Rubber Grommet

 

4 ea . Wall Plug

 

4 ea . Wall Fixing Screws

 

2 ea . Ceramic bracket

 

2 ea . Clevis Pin

See ordering instructions on 

Page 24

WARNING

CLEARANCES FROM COMBUSTIBLE MATERIALS

F860041/A

The following clearances must be maintained at all times.
Failure to do so may result in the risk of a fire.
For full information refer to the instruction manual 
provided with the heater.

Note : Zero clearance from bottom of heater frame 
required for hard combustible floors. Minimum 4” 
clearance required to rugs or any fabric floor 
coverings. REFER TO INSTRUCTION MANUAL

IMPORTANT : Fabrics, curtains and drapes are not 
permited above the heater at any distance and within 
20” of the heater sides. No combustible shelves of any 
size are permitted above the heater.

Clearance to 
combustible 
sidewalls 4” 
(both sides)

Clearance to combustible ceiling 
32” measured from top of appliance 
glass panel

Clearance in 
front of 
heater 20”

F860041/A

Deben mantenerse en todo momento los siguientes espacios 
libres. El no hacerlo puede causar un riesgo de incendio. 
Consulte el manual de instrucciones suministrado con este 
aparato para obtener información completa.

Nota: No se requiere espacio libre desde el borde inferior del 
marco del calentador en caso de pisos combustibles duros. 
Se requiere un espacio mínimo de 4” entre el calentador y 
cualquier alfombra, moqueta o revestimiento de suelo de 
tela. CONSULTE EL MANUAL DE INSTRUCCIONES.

IMPORTANTE: No se permite la colocación de telas, cortinas y 

similares por encima del calentador a cualquier distancia, ni a 

una distancia de 20” de los laterales del calentador. No se 

permiten estantes combustibles de cualquier tamaño por 

encima del calentador.

Espacio hasta
paredeslaterales
combustibles
4” (ambos lados)

El espacio de 32” hasta un techo 
combustible se mide desde el borde 
superior del panel de vidrio del aparato

Espacio libre
delante del
calentador 20”

ADVERTENCIA

ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES

FIREBO

X OUTLINE

C

ONT

ORNO DE LA CAMARA DE C

OMBUSTION

POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL

COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED

PIERCE TEMPLATE TO MARK HOLE POSITION ON WALL X 4

CENTRE LINE

17-3/16”

 (437mm)

CONCEALED

GAS INLET

ENTRADA DE

GAS OCULTA

1/2”

(13mm)

16” (406mm)

FIXING POINTS

Scandium

FIXING POINTS

PUNTOS DE SUJECION

PERFORE LA PLANTILLA PARA MARCAR LA POSICION DE LOS 4 TALADROS EN LA PARED

PUNTOS DE SUJECION

LINEA DE CENTRO

WALL MOUNTED VENT FREE FITTING TEMPLATE

PLANTILLA PARA LA INSTALACION DE CHIMENEAS DE PARED SIN SALIDA DE HUMOS

IMPORTANT

THIS APPLIANCE IS TO BE WALL HUNG ONLY. 

DO NOT RECESS OR INSET ANY PART OF THE APPLIANCE.

THIS TEMPLATE IS FOR THE MARKING OF FIXING POINTS ONLY.

 DO NOT INSTALL THE APPLIANCE WITH THIS TEMPLATE IN PLACE.

IMPORTANTE

ESTE APARATO UNICAMENTE DEBE SER COLGADO EN UNA PARED.

NO EMPOTRE NINGUN ELEMENTO DE ESTE APARATO.

ESTA PLANTILLA SIRVE UNICAMENTE PARA MARCAR LOS PUNTOS DE FIJACION.

RETIRE LA PLANTILLA ANTES DE COLOCAR LE APARATO.

APPLIANCE OUTLINE 

 

C

ONT

ORNO DE LA AP

ARA

TO

DO 005855/0 - ISSUE A

FocalPointFires Single   24/04/08   

DO 005855/0 

Lennox L40 Scandium fitting template

Ref. Paul West - Focal Point Fires. Any problems please call 01202 588629

Artwork Size: W1055 x H530

5

4

10

Hardware

4

3

13

Summary of Contents for SCANDIUM-LP

Page 1: ...roperty damage personal injury or death Ne pas entreposer ni utilizer d essence ni d autres vapeurs ouliquidesinflammablesdanslevoisinagedecetappareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez à aucan interrupteur Ne pas vous servir des téléphonessetrouvantdanslebâtimentoùvoustrouvez Appelez immédiatement votre fournisseur de ...

Page 2: ...ure many years of dependable and enjoyable service from your fireplace Register your product online today To help us keep you up to date on product information and offers please take a few moments to register your product online at www lennox com Hearth Owner Resources Safety and Your Fireplace 2 3 Important Safety Information 4 Appliance Installation Service and Maintenance Notices 5 Appliance Op...

Page 3: ...écurité Page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTRÊMEMENT CHAUDES Instale una malla o barrera física para evitar el contacto directo con el vidrio y prevenir las quemaduras y lesiones graves Siga las instrucciones de seguridad a continuación y asegúrese de que todos en su hogar sepan acerca de este peligro de quemadura Las superficies de la chimenea se ponen MU...

Page 4: ...ec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et aux surfaces chaudes 7 Tout écran ou protecteur retiré pour permettre l entretie...

Page 5: ...ppliance is Not convertible for use with other gases These appliances are designed to operate on natural gas or propane gas only The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous Provide adequate clearances around air openings and adequate accessibility clearance for service and proper operation Never obstruct the front openings of the...

Page 6: ...areshowninBTUperhourandareforelevations up to 4 500 feet Do not install this heater at an elevation above 4 500 feet if the gas supply has not been derated for thatelevation Consultyourlocalgassupplier Foroperation at elevations above 4 500 feet equipment ratings shall be reduced at the rate of 4 percent for each 1 000 feet above 4 500 feet before selecting appropriately sized equipment When insta...

Page 7: ...ements These fireplaces are approved for installation in the US state of Mas sachusetts if the following additional requirements are met Unvented Room Heaters shall be installed in accordance with 527 CMR and 248 CMR Installationandrepairmustbedonebyaplumberorgasfitterlicensed in the Commonwealth of Massachusetts The flexible gas line connector used shall not exceed 36 inches 92 centimeters in len...

Page 8: ...____ volume of space ft3 50 ft3 Maximum BTU Hr the space can support Example 3072 ft3 50 ft3 61 44 or 61 440 BTU Hr the space can support 3 Add the BTU Hr of all the fuel burning appliances in the space Vent Free heater _______ BTU Hr Gas appliance 1 _______ BTU Hr Gas appliance 2 _______ BTU Hr Gas appliance 3 _______ BTU Hr Total _______ BTU Hr Example Vent free heater 1 9 000 BTU Hr Vent free h...

Page 9: ... as scorching and or discoloration may occur over time If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to carry the weight of the appliance must be confirmed It is important in these circumstances that any vapor control barrier is not damaged and that any structural members of the house frame are not damaged The ...

Page 10: ... made ensure the gas supply pipe is in it s final position and can enter the appliance in the correct position when the appliance is hung on the wall Figure 2 Wall Fixing Template WARNING CLEARANCES FROM COMBUSTIBLE MATERIALS F860041 A The following clearances must be maintained at all times Failure to do so may result in the risk of a fire For full information refer to the instruction manual prov...

Page 11: ...oom heater to the gas supply Consult all local codes The installer must provide an ANSI approved manual shut off valve flex connector and 3 8 NPT fitting A flex gas line kit with shut off valve is available see Page 20 for ordering information Route gas line using techniques and materials prescribed by local and or national codes Only use pipe of 1 2 or greater size to allow full gas volume to the...

Page 12: ...rner If any ports are blocked or partially blocked clean out the ports GAS PRESSURE CHECK The heater regulator controls the burner pressure which should be checked at the pressure test point located on the appliance inlet pipe The appliance inlet pipe runs between the regulator and the gas valve and the test point is located next to the regulator as shown in Figure 5 WARNING Never use an open flam...

Page 13: ... screws should be finger tightened until all side and top frame pieces are assembled and aligned At that point tighten the screws in 1 4 turn increments until frame pieces are firmly positioned and do not move If you find that your glass facia is experiencing slippage because of this over tightening of the screws you can use normal RTV sealant to secure the glass facia to its bracket Remove the fa...

Page 14: ... and fit onto the sides of the firebox as shown Insert the M6 retain ing screws in the sides of the firebox and ensure they are unscrewed approximately 1 8 so the keyhole shaped holes may engage and the sides can be hooked on Note Frontframe facia not shown for clarity Insert a screwdriver through the holes in the right hand side panel to access the two M6 fixing screws designated a in Figure 17 a...

Page 15: ...once annually Advise that cleaning of the appliance may be achieved when the appliance is cold using a damp cloth and mild detergent on most surfaces Advisethattheappliancewillemita newness smellforatimeafterinitial commissioningandthatextraventilationmaybeneededduringthistime Advise the user to never place any objects on top of the appliance or obstruction this area in any way A periodic visual c...

Page 16: ...e released Undo the four screws retaining the burner brackets to the base and rear of the firebox The burner may now be removed Remove the pilot and main burner pipes and blow through to dislodge any debris Now remove the in line restrictor and blow through to make sure it is entirely clear Unclip the pilot lint gauze and clean with a soft brush Clean the exterior of the pilot assembly with a soft...

Page 17: ...pellet or match introduced at the base of the fire underneath the burner tray Large quantities of smoke will emerge from the top of the appliance but none should emerge from the joints or gasket faces especially around the door It is important to note that the appliance can never be expect ed to be 100 smoke tight and small quantities of smoke may be seen in corners of joints and gasket faces etc ...

Page 18: ...ated on the left side behind the burner Figure 20 7 Depress control knob in and turn counter clockwise to the SPARK position Figure 19 and hold there for a few seconds Note If you are running the heater for the first time or after an extended period of non use it will be necessary to press the control knob all the way in for 30 seconds to allow air to bleed out of the gas piping 8 Continue turning...

Page 19: ...em with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY LIT Pilot flame shrinks when fire is on high Poor gas flow to fire check pressure with fire on high If pressure is low remove any restriction in pipe work or valve Check all pipe work are adequately...

Page 20: ... borde inferior del marco del calentador en caso de pisos combustibles duros Se requiere un espacio mínimo de 4 entre el calentador y cualquier alfombra moqueta o revestimiento de suelo de tela CONSULTE EL MANUAL DE INSTRUCCIONES IMPORTANTE No se permite la colocación de telas cortinas y similares por encima del calentador a cualquier distancia ni a una distancia de 20 de los laterales del calenta...

Page 21: ...ur 4 screws indicated then lift door off 4 off burner installation positions Figure 21 WARNING Failure to position the parts in accordance with these diagrams orfailuretouseonlypartsspecifi cally approved with this heater may result in property damage or personal injury Figure 22 Visual check for cor rect pilot flame ...

Page 22: ...ATIONS SCANDIUM 20 13 16 10 1 4 41 1 2 27 11 16 18 5 8 5 9 16 7 1 8 30 1 16 16 Product Reference Information Cat No Model Ship Wt Ship Volume H6065 Scandium NG 80 7 lb 12 9 cu ft H6071 Scandium LP 80 7 lb 12 9 cu ft Back View Bottom View Front View Side View ...

Page 23: ...s are converted from millimeters and are rounded to the nearest 1 16 KEY D1 Distance from mounting surface to rear entry point D2 Distance from mounting surface to center of side entry point D3 Distance from mounting surface to regulator gas entry point GAS ENTRY POINT DIMENSIONS D3 D1 D2 REGULATOR GAS ENTRY POINT D1 D3 D2 Finished Wall TOP VIEW Fireplace Regulator Gas Entry Point ...

Page 24: ...rts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation or applicat...

Reviews: