34
TROUBLESHOOTING
QUALIFIED TECHNICIANS ONLY
Unplug Appliance Before Performing Any Troubleshooting or Maintenance
Ignition/Proof of Fire Failure - Message - No Fire Error
Possible Problem
Solution
Hopper is out of pellets
Fill the hopper with pellets
Auger tube was not full of pellets when the start dial was activated
When cool, empty pellets that are in Burn-Pot. Turn ignition/heat control
dial off and then back to your desired heat setting.
Burn-Pot dirty - holes plugged
Clean the Burn-Pot making sure all holes are clear of ash and clinkers
Igniter not functioning
Check igniter fuse or replace igniter
Igniter fuse blown
Replace 6 amp fuse located on the side of the controller.
Proof of Fire Snap Switch defective
Replace Proof of Fire Snap Switch
Proof of Fire Snap Switch dirty
Clean Proof of Fire Switch (See instructions on
Page 28)
Vacuum Switch Shuts Stove Down - Message - Air Seal Error
Front door is not sealing
Latch or adjust the front door. Replace door gasket if worn or dam-
aged
Ash pots are not sealing
Close latches, adjust latches, or replace drawer gaskets
Flue gas passageways restricted
Clean the passageways (see
Page 28)
Vent pipe restricted
Clean the vent pipe (see
Page 29)
Vacuum hose plugged
Clean or replace the vacuum hose
Vacuum switch defective
Replace the vacuum switch
Proof of Fire Snap Switch Shuts Stove Down - Message - No Fire Error
Hopper is out of pellets
Fill the hopper with pellets
Snap switch* defective
Replace the "proof of fire" snap switch
“Proof of fire” switch is dirty
Clean switch per instructions on
Page 28
Control Board has no Power - When heat select dial is turned, no lights light up
Power cord is not plugged in
Plug in power cord
Board fuse blown
Replace 3 amp fuse located on side of control board
Wall outlet not energized
Check circuit breaker panel
Board broken, damaged, or defective
Replace the control board