Neuron activity
The Neuron is a specialized internal microprocessor. The LEDs labeled TX and RX indicate Neuron
activity. These LEDs will be flickering under normal operation.
System Faults
Any system fault will be shown on the display by its fault code as shown below.
CPU
Detail
Heartbeat?
8-1
Failure during variable initialization
No
8-2
I2C Failurereading Super Inputs a2D
No
8-3
I2C Failure writing to LCD Control
No
8-4
I2C Failure writing to Aux Relays
No
8-5
I2C Failure writing to fault leds
No
8-6
I2C Failure writing toI2C multiplexer switch
No
8-7
I2C Failurereading Voltage a2D
No
8-8
I2C Failure writing to Dig In LEDs
No
8-9
I2C Failure writing to LCD Data bus
No
8-10
I2C Failure writing to Audio FX Chip
No
8-11
Power supply Voltage Failure
No
8-12
I2C Failure reading/writing UART
No
8-13
I2C Failure writing to Potentiometer
No
A fault can be muted or cleared. Muting the fault only silences the warning tone
for 24 hours
. Clearing
the fault can only be accomplished after the fault is rectified.
See “Operation Examples” for more
information.