LEMET ECOWAY 100 Operation And Installation Manual Download Page 7

 

 

Lemet Greenline and Ecoway can only be installed vertically. Lemet Horizontal can only be 
installed horizontally with the hot water outlet and cold water inlet facing downwards 

 

Fit all components supplied 

 

The water heater is not suitable for outdoor installation 

 

It is forbidden to install the heater in places with explosion hazard, in a location with acid 
vapors and/or dust, or in gas-saturated environments or exposed to freezing temperatures, 
causing the freezing of water in the tank, in the places where the heater must be exposed to 
water vapor. In the case of the assembly, installation, and operation of the water heater in 
unusual places (e.g. in the attic, indoors in rooms with floors sensitive to water, in cabinets, 
etc.), it is necessary to take into account the possibility of the possible water leakage and in 
connection with that, take appropriate preventive measures enabling the connection of water 
and its drainage in order to prevent secondary damage 

 

IMPORTANT: 

We strongly recommend to install a 

pressure reducing valve 

if the water 

pressure is too high (5 bar or more) or if you suffer from fluctuating water pressure. High water 
pressure and/or fluctuating water pressure often occur in apartment building, flats, farms, 
older houses and houses and buildings in elevated areas. Install a pressure reducing valve 
where your mains water supply line enters your premises or right behind the pressure relief 
valve. Ensure the water pressure is set at 3 bar. Any damage caused by a too high water 
pressure or fluctuating water pressure will not be covered by the warrantee. 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

Pressure reducing valve 

 

3.1 Connection to the water supply system

 

The heater must be connected to the mains water supply in such a way that it allows easy 
disconnection for maintenance without damaging the connections and destroying the installation. The 
minimum free space must be 30 cm for easy access in case you need to replace the heating element 
or the anode. It is forbidden to cut the connection muffs to the water supply system, since this may 
cause damage of the corrosion protection coating.  

The connection of cold water is marked with a blue band, and the outflow of hot water is marked with a 
red band.

The tanks may only be connected to the mains water supply whose water is compliant with 

the requirements of the Council Directive 98/83/EC of 3 November 1998 on the quality of water for 
human consumption and competent in the field of the national legislation.  

It is forbidden to apply plastic hoses for connection, which are not adapted to temperatures higher 
than 110C and pressure exceeding 1.0 Mpa. It is recommended to use flexible connection hoses 
specifically designed for hot water. Always use pressure and temperature resistant pipes and 
connectors.  
 

Models: Lemet Greenline vertical/ Greenline Horizontal/ Ecoway vertical/ Small  - assembly in 
pressurised version 

 

The water heater can be connected to a water supply system with the pressure not exceeding the one 
determined for a given tank type in chapter TECHNICAL DATA.

In the domestic hot water installation, 

it is recommended to install a diaphragm vessel for domestic water in order to minimize the effects of 
the so-called "hydraulic impact" or sudden pressure surges.  

Summary of Contents for ECOWAY 100

Page 1: ...NUAL WALL MOUNTED UNVENTED ELECTRIC WATER HEATERS LEMET GREENLINE 30 50 80 100 120 and 200 Liter vertical and horizontal LEMET ECOWAY 50 80 100 120 and 200 Liter SMALL 5 and 10 liter under sink and ov...

Page 2: ...Do not use the water heater when frozen Wait until the water flows again in the water heater before using 3 Do not attempt to repair but call a certified installer Failing to do so will void your warr...

Page 3: ...um tank working pressure Mpa 0 6 0 6 0 6 Connection port spacing cm 10 10 10 Tank diameter Total height cm 44 56 44 80 44 93 Protection rating IP 24 24 24 Net weight without water kg 17 23 27 1 Domest...

Page 4: ...utlet 10 Discharge pipe to drain of expansion water GREENLINE Electric water heaters 50L 60L 80L 100L Time of heating up to 65OC t 45 min 80 95 125 160 Rated voltage V Hz 230 50 230 50 230 50 230 50 E...

Page 5: ...rature control 5 Cable with plug 6 Pressure relief valve 7 Drain valve install a discharge pipe underneath 8 stopcock on the mains water supply line 9 Stopcock on hot water outlet 10 Under sink pressu...

Page 6: ...an electronic controller An overheat protection of water heated by the electric heating element is in this case a non automatic temperature limiter which disconnects the electric circuit when the wat...

Page 7: ...ure or fluctuating water pressure will not be covered by the warrantee Pressure reducing valve 3 1 Connection to the water supply system The heater must be connected to the mains water supply in such...

Page 8: ...eater free of charge to the orifice on the pressure relief valve facing downwards to drain of expansion water uninterruptedly to a drain 2 A KIWA approved safety relief valve If you have installed a K...

Page 9: ...to the water heater The pressure relief valve must remain open to atmosphere and never further away than 2 metres from the water heater Always install the pressure relief on the cold water inlet side...

Page 10: ...o ensure an even longer lifespan of your water heater 6 GREENLINE and SMALL set the temperature with the thermo regulator knob It is recommended to set the knob in just below the MAX setting of the re...

Page 11: ...s set the required temperature within the scope of 20 to 75 C and after setting and approx 3 5 sec the controller will display the required and current temperature 4 3 2 ECOWAY ECO WORKING MODE It is...

Page 12: ...ram ECO mode is set Press the up and down buttons to select the temperature for the first program Or press the ECO button selecting the ECO mode for the first program and confirm with OK d The display...

Page 13: ...of the heater by eliminating the possible risk of electric shock 4 5 ECOWAY Error codes Er01 the temperature limiter was triggered exceeding the permissible water temp inside the tank Before re connec...

Page 14: ...ss of neutral earthing 5 3 Cleaning maintenance and replacement of the magnesium anode The heater should be cleaned with a damp cloth without the use of aggressive abrasive cleaning agents It is recom...

Page 15: ...Draining the water heater Take the power cord from the power socket Place a bucket underneath the cold water inlet side BLUE marking Close the stopcock on the mains water supply and then remove the pr...

Page 16: ...11 Use a water hose to rinse out any limescale from inside the tank Alternatively take the water heater from the wall place the unit in the bathtub or in the shower and use the shower hose to rinse ou...

Page 17: ...alve usually bloated tank or cracked cylinder is not covered by the warranty it applies to the assembly in the pressurised version Using the heater in water supply networks with a pressure greater tha...

Reviews: