background image

Page 1/15 

28October2022/Version 7 

LEM reserves the right to carry out modifications on its transducers, 

 

in order to improve them.

LEM International SA 

Route du Nant-d’Avril, 152

1217 Meyrin 

 www.lem.com

Current Transducer ITZ 5000-S FLEX ULTRASTAB 

I

P N

 =  5000 A

N° 88.23.75.100.0

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation 

between primary and secondary. Separate magnetic head and measuring electronics provides 

high flexibility.

Features

 

● Closed loop fluxgate

 

Split design - separate head 
and rack electronics

 

Analog output on 15-pin D-sub female output connector

 

Status/interlock port on 9-pin D-sub male output connector

 

Secondary current monitoring on BNC connector

 

4 mm banana sockets for secondary current output

 

Full-featured indicator panel.

Advantages

 

Very high accuracy

 

● Excellent linearity

 

● Extremely low temperature drift

 

Wide frequency bandwidth

 

● High immunity to external fields

 

No insertion losses

 

Low noise on output signal

 

Low noise feedback to primary conductor.

Applications

 

Feedback element in high-precision, high-stability power 
supplies

 

Calibration unit

 

Absolute current standard reference

 

Test and calibration of current sources

 

● Current extender for power systems

 

● Differential current measurement on power line

 

Metrology applications.

Standards

EMC: 

 

EN 61000-6-2: 2019

 

EN 61000-6-3: 2007 + A1 (2011)

 

EN 61326-1: 2013

Safety: 

 

IEC 61010-1: 2010/AMD1: 2016.

Application Domains

 

Industrial

 

Laboratory

 

Medical.

Summary of Contents for ITZ 5000-S FLEX ULTRASTAB

Page 1: ...9 pin D sub male output connector Secondary current monitoring on BNC connector 4 mm banana sockets for secondary current output Full featured indicator panel Advantages Very high accuracy Excellent...

Page 2: ...required cleaning by dry compressed air is authorized This transducer is a build in device whose hazardous live parts must be inaccessible after installation This transducer must be mounted in a suit...

Page 3: ...ons over voltage cat III pollution degree 2 Rated insulation RMS voltage reinforced insulation UNm V 2000 IEC 61010 1 conditions over voltage cat III pollution degree 2 RMS voltage for AC insulation t...

Page 4: ...ion IP 0 A Mains supply 230 V RMS PC W VA 38 82 Average Peak Power consumption IP IP N DC 5000 A Mains supply 230 V RMS PC W VA 76 116 Average Peak RMS noise current 0 10 Hz 2 Ino ppm 0 02 RMS noise c...

Page 5: ...40 45 50 RM 0 5 RM 1 RM 1 5 Cable length m provided by LEM Primary nominal RMS current versus Cable length TA 0 to 55 C Primary nominal RMS current A Primary nominal RMS current versus cable length Pr...

Page 6: ...000 4000 3000 2000 1000 0 1000 2000 3000 4000 5000 6000 7000 8000 0 5 10 15 20 25 30 35 40 45 50 RM 0 5 RM 1 RM 1 5 Cable length m provided by LEM Primary current measuring range versus Cable length T...

Page 7: ...them LEM International SA Route du Nant d Avril 152 1217 Meyrin www lem com ITZ 5000 S FLEX ULTRASTAB Typical power consumption 0 10 20 30 40 50 60 70 80 90 6000 5000 4000 3000 2000 1000 0 1000 2000...

Page 8: ...d LED This LED is lit when the transducer head saturates due to excessive primary current 600 A 24000 A yellow LED These LEDs are lit when a transducer head with the corresponding full scale range is...

Page 9: ...tatus Interlock signal outputs 9 pin D Sub male UNC 4 40 screw lock 8 Option A B These positions are for future expansion or customization not used 2 8 3 1 7 6 5 4 LEM International SA Route du Nant d...

Page 10: ...is wired it can be Active Low or Active High as shown below In the Diagram A Active Low Output the output signal Uout switches to GND when the corresponding LED is ON In the Diagram B Active High Outp...

Page 11: ...ducer head is not saturated High IP UC The primary current is higher than 105 of nominal full scale output 0 2 V The primary current is lower than 105 of nominal full scale output ACTIVE UC The primar...

Page 12: ...off When the rack electronics temperature cools to approximately 60 C the measuring circuit is automatically re enabled and the status LED is again lit Over current protection Electrical specification...

Page 13: ...AC peak becomes lower than the trip level indicated in the table above Transducer head description Connect the transducer head to the electronics rack using the supplied transducer head cable The sid...

Page 14: ...ransducer head European Schuko CEE 7 7 and US Japanese mains cables 2 m each with three pole IEC C13 female connector Short plug for 4 mm banana terminals and 15 pin D Sub short plug for analog output...

Page 15: ...modifications on its transducers in order to improve them LEM International SA Route du Nant d Avril 152 1217 Meyrin www lem com ITZ 5000 S FLEX ULTRASTAB Dimensions Rack electronics in mm general tol...

Reviews: