Calibration
Primary Training
4.2.1 Calibrate one current input with interruptible terminals (RTK/S, MTK
P/P,...)
1.
Short cut signal input, USER side; be sure that USER current circuit will
never be open !
TERMINALS
+
-
+
-
USER
SIGNAL
11A1
+
-
INPUT
CARD
11A11
USER SIDE
BEN SIDE
REFERENCE
CURRENT
SOURCE
2. Open switches of both terminals
TERMINALS
+
-
+
-
USER
SIGNAL
11A1
+
-
INPUT
CARD
11A11
USER SIDE
BEN SIDE
REFERENCE
CURRENT
SOURCE
Page 26
9200-14 REV. E