6.5
Alarm functions
Supervision functions
active on
Call in..
I
II
III
Emergency call
..hands-free connection
Emergency call activated…
Misuse protection
6
6
..will be cancelled
The door is open,…
Sensor-1 (can be deactivated)
6
6
..service connection
Alarm due to Sensor-1
Sensor-3
..service connection
Alarm due to Sensor-3
Power failure (can be deactivated)
..service connection
Alarm due to power failure
Routine call
..service connection
Periodical test call
6.5.1
Emergency call
The emergency call is triggered when the button is pressed during a specific time. EasyAlarm® starts to dial calling
number(s) according to the calling number sequence in hands-free connection.
Notes:
Factory delay time: 1 second.
EN81-70: Yellow lamp on the sub-communication unit is activated.
Alarm forwarding to the building control system
6.5.1.1
Misuse protection
If selection switch is on position III an alarm is only triggered, if the door contact does not change within a pre-programmed
period (it is recommended to program this time according to the longest possible travel of cabin, factory set to 30 seconds.
During this pre-alarm period following information is provided:
If the door state changes you will hear:
If the door contact does not change within this period, EasyAlarm® starts to dial calling number(s) according to the calling
number sequence in hands-free connection.
Notes:
Factory misuse protection time-out (=maximum travel time.): 30 seconds
In case of emergency operation (supply loss and low battery) there will be no misuse protection.
6.5.2
Alarm due to Sensor-1 (Alarm contact)
If selection switch is on position II an alarm will be triggered in active supervision mode as soon as the Sensor-1 contact is
activated. EasyAlarm® starts to dial calling number(s) according to the calling number sequence in service mode.
6.5.3
Alarm due to Sensor-3 (Alarm contact)
On all position of the selection switch an alarm will be triggered as soon as the Sensor-3-contact is activated. EasyAlarm®
starts to dial calling number(s) according to the calling number sequence in service mode.
6.5.4
Alarm due to power failure
If the supply voltage fails for a defined period, EasyAlarm® calls routine number 9 in service mode.
Notes:
After power up EasyAlarm® mains power will be tested. If there is no mains power you will hear .
Once the power supply is detected, EasyAlarm® automatically activates power failure monitoring.
Factory network downtime: 120 Min.
Alarm power failure to calling number sequence
9.5.2 (Factory setting to routine number 9) .
6.5.5
Routine call
When routine call is activated EasyAlarm® calls routine number 9 in the selected interval
9.4. To enable routine call,
make a remote access dial
6.9, enter touch-tone
**#1
or a similar command
EN81-28:2018: If no acknowledgement (DTMF C) is received from the receiver during the routine call, this is signalled by
an alternating flashing of the two EN81-70 symbols
since version 8.51
14
Emergency call activated. You are about to be connected
Cause of alarm
The door is open. Emergency call deactivated. Alarm acknowledged
Emergency call activated
Alarm due to Sensor 3
Alarm due to power failure
Periodical test call
Emergency call activated. You are about to be connected
Power failure
Alarm due to Sensor 1