16
7.7
Alarm repetition
If an alarm has not been acknowledged by passing all the calling numbers in the sequence, a number of alarm
repetitions can be programmed (
programming 10.2). Factory setting: two alarm repetitions.
7.8
Test call
If alarm unit is switched to ON it is possible to start a test call as follows:
1.
Select calling number by pressing key
<n>
(
n
=
1
.
..
9
)
¦
Announcement: „Calling number
<n>
“ => If selected calling number is not programmed the
message “Error” will be announced and the first calling number will be dialled instead
2.
Wait until
hands-free connection
is established and speak
3.
Terminate
phone connection
by pressing
0
.
or slide
function switch
to OFF
Notes:
After two minutes
phone connection
will automatically terminate if called party does not give any
tone-
dialling commands
(i.e. called subscriber can disconnect using DTMF 0 or restart timer using DTMF 3 ).
During
inactive waiting period
after power on key
9
.
and
7
.
activate or deactivate the monitoring of the
supervision. Key
5
.
starts the announcement of the current supervision mode (
section 7.3)
The volume of
hands-free connection
can be adjusted as described in section 7.6.4.1
7.9
Dialling-in (check call)
If the alarm unit is switched to ON you can dial in from any telephone set as follows:
1.
Dial phone number of the
EasyAlarm®
2.
Let it ring for two ringing cycles and disconnect (hang up)
3.
Redial after 20 seconds =>
EasyAlarm®
answers call after two ringing cycles and waits for the PIN-Code
After entering the correct PIN-Code
EasyAlarm®
establishes a
listening-in connection
¦
Announcement „to stop press 0,to speak press 1“
If no
tone-dialling command
is entered, the
phone connection
will be terminated after two minutes
connection
time-out
. The supervised person can also terminate the phone connection by pressing the emergency button.
Important: In case that there are unconfirmed alarms, the quantity as well as the last reason of the alarm will be
announced! An unacknowledged alarm will be confirmed by entering DTMF 0 !
Notes:
The two-step dialling in procedure is for security reasons to avoid detecting of the alarm unit coincidently
by an unknown caller. Direct dialling in as well as other number of ringing cycles can be selected (
section 10.7)
If the PIN-code is incorrect or not entered within 15 seconds,
EasyAlarm®
disconnects after the
announcement „PIN error, abort“ => try again and enter correct PIN.
PIN-code is factory set to 9797. For safety reasons we recommend changing PIN-code and program your
individual code according to the manual.
If a successful dialling-in should be signalled with five gong-signals (to alert/inform the supervised person),
EasyAlarm®
can be programmed according section 10.7.3.
7.10
Answering an incoming call
An incoming call, signalled by a parallel connected phone, can be answered as follows (
Function switch
ON):
7.10.1
..by pressing the emergency button
a
hands-free connection
is established => Disconnect by pressing the emergency button once again.
7.10.2
..by pressing any key of the alarm unit
a
hands-free connection
is established => Disconnect by pressing key
0
.
(
section 10.7.4).