Alarm release
7.4.1
..independent from state of arming (armed / disarmed)
Active by
Factory set
alarm cause
1)
I II III
Entry delay
Alarm
connection
Announce the alarm cause
Panic
Instantaneously
Listening-in
“Emergency call activated”
Emergency
2)
Delayed
Hands-free
“Emergency call activated”
Smoke
Delayed
Hands free
“Alarm due to fire zone
n
”
Sensor 3
3)
Instantaneously
Listening-in
“Alarm due to zone
n”
1.
Factory setting cause of alarm (user specific changes not mentioned)
2.
An emergency call will be triggered, if the button has been activated for one second. After a pre alarm
period of 20 seconds the text “emergency call activated” is announced. A pre warning announcement is
used to avoid false alarms (i.e. technical error like power failure, unwanted emergency calls). During the
pre warning period the alarm can be cancelled by pressing the emergency button respectively by pressing
key
0
.
3.
Sensor 3 can be enabled as alarm sensor (NO or NC).
7.4.2
..if system is armed only
Active by
Factory set
alarm cause
1)
I
II III
Entry delay
Alarm
connection
Announce the alarm cause
Sensor 1
4)
Instantaneously
Listening-in
“Alarm due to sensor 1
“
Presence verification
5)
10 minutes/30 seconds
Hands-free
„Alarm due to presence
verification
“
Sensor 2
6)
Instantaneously
Listening-in
“Alarm due to sensor 2
”
Noise
7)
Instantaneously
Listening-in
“Alarm due to noise
”
Power failure
8)
Delay 1 min
Hands-free
“Alarm due to power failure
”
4.
Sensor 1 can also be used as a presence verification sensor (
section 6.6)
5.
If there is not motion detected within a period of 24 hours EasyAlarm
®
triggers an alarm, provided
programming is set to presence verification (
section 6.7). Before starting the alarm there is a pre warning
period of ten minutes. If activation is detected (motion detected or emergency button pressed) within this
period, the alarm is triggered
.
6.
Sensor 2 can be enabled as alarm sensor (NO or NC).
7.
Noise monitoring according to section 6.6: To avoid false alarm close windows and eliminate other noise
sources.
8.
EasyAlarm®
monitors mains voltage and triggers an alarm if power loss is longer than 10 to 20 minutes.
The mains power monitoring does not start if after power up the mains power is not detected. In this case
the message „power failure“ will be announced. After any mains power detection
EasyAlarm®
automatically start power monitoring.
7.5
Alarm delay / Pre warning period / Entry delay
An alarm can be delayed due to following reasons:
9
An alarm sensor in the area of the entrance must be delayed to have enough time to switch off the
supervision mode before
EasyAlarm®
dials the first calling number.
9
A pre warning announcement is used to avoid false alarms (i.e. technical error like power failure, unwanted
emergency calls). During the pre warning period the alarm can be cancelled by pressing the emergency
button respectively by pressing key
0
.
.
¦
Announcement: „Alarm
acknowledged“
Notes:
The entry/exit period can be adjusted according to section 10.3.
If an alarm has been triggered by pressing the emergency button, cancellation of the alarm is only possible,
if the button has been released for min. 3 seconds before pressing it again.
7.5.1
Siren activation during pre warning period
If you use a siren (
section 11.1) which is activated as described in section 10.5.2, the pre alarm period is
signalled by a periodical siren tone.