11
5.5.2 Define zones
The alarm unit can handle up to 10 zones (zone 0 to 9). Please write down the transmitter type and sensor
function in the table at section 4.2 after the learn-in process, in order that later you need handle on it again.
5.5.3 Learn in transmitters
1. Slide
function switch
to PROG
2. Enter
*
.
*
.
*
.
3. Press key
0
.
to
9
.
according to desired zone
4. Press key
0
.
to
9
.
according to transmitter type (to handle the kinds of alarm and telephone connection
see table 5.5.1)
Message announce „Zone n, to modify press *“
5. Press
*
.
and start learn-in process according to the specified radio component.
A successful learn-in will be confirmed with a beep tone. By activating the transmitter again, a
loud beep tone will be generated as long you are within transmitting range. You can control this way
by reception range and to select the best suitable location of the unit.
6. Slide
function switch
to OFF
Important note:
Zones with sensor function 1 (Fire) to 6 (Extern) or 0 (Remote lock) are automatically supervised for
the periodical status-signal. If the periodical signal is missing for a given period (
section 9.11.1) the
system announces the “missing” zone and in armed state an alarm will be triggered.
5.5.4 Delete a zone
1. Slide
function switch
to PROG
2. Enter
*
.
*
.
*
.
3. Press key
0
.
to
9
.
according to the zone to be deleted
4. Press key
#
.
0
.
.
Announcement “ zone n to modify press star”
5. Press key
*
.
6. Slide function switch to OFF
Important note:
If the tamper contact of a telecommand key switch or remote lock (sensor function 9 and 0) is
detected the appropriated zone will automatically deleted. Therefore you have to check, that the
alarm-unit is switched off, if you want to change the battery. Otherwise you have to re-program it.
5.5.5 Check radio reception
You can check or optimise location of alarm unit as follows:
1. Slide
function switch
to PROG
2. Enter
*
.
*
.
*
.
*
.
and press wireless button/sensor
Each time if you activate a learned-in sensor, the alarm unit announces its zone number. An
unknown sensor provokes a beep. Any other signal or noise will be passed directly to the
loudspeaker.
3. Slide
function switch
to OFF
Note:
You can optimise location of alarm unit regarding the following points:
a.
Place alarm unit as far away from possible emitters
b. Do not place alarm unit near a shielding cover
c.
Place the alarm unit in the centre of the wireless sensors, to minimize transmission range.
5.5.6 Wireless components
5.5.6.1 RWT 33 (Smoke detector)
Mounting instruction:
The radio detector is to be mounted on the ceiling in the middle of the room.
It has a detection area of 40sqm. First remove the red protection cap.
Turn the bottom shell of the smoke detector counter clockwise and separate it from the rest
of the detector.
Preparation for programming:
Open the battery cover on the bottom of the detector.
Learn-in procedure:
insert battery.
Sensor function:
fire (with status report every 65 minutes)