Leitronic AG EA-8-WRL868 Use Instruction Download Page 13

13

Battery replacement
A battery test is performed during each transmission. If the battery is low the red LED will
blink during each transmission, indicating that the battery must be replaced. If so, the alarm
unit EasyAlarm will announce “battery failure”. Change battery as soon as possible.

Battery type is Lithium CR2032 and can be found from different manufactures. Please refer to
their handling- and safety-instructions.

Please check:

Insert with right polarity.

Avoid any moisture.

Never short circuit battery.

Never use faulty batteries.

Run the disposal of used batteries according to the legal rules.

Use protective gloves to remove corroded or leakage batteries

.

5.5.6.6 RWT 92 (motion detector)

Assembly instructions:

The radio motion detector reacts to change in heat movement. It is to be mounted looking
into the room at a heights of ca. 2.30m. it is best to mount in a corner.

Open the detector and remove the screw, which hold the circuit board.

Remove the circuit board and break away the designated parts of the lower shell.

Mount the lower shell to a wall with the provided screws, reinsert the circuit board and then
close the detector.

An integrated LED makes it possible to conveniently check the surveillance area. You might
need to move the circuit board a few millimetres up or down

Keep in mind not to mount the detector above heat sources, such as fax machines, radiant
heater or air conditioner, or across from the window. The lens of the detector is not to be
covered with a curtain or other covers, as then no surveillance takes place.

Preparation procedure for programming:

If not yet open, open the detector with a screwdriver on the bottom and remove the upper- from
the lower shell. Take the 3V-lithium battery from its wrapping and install it, paying attention to
correct polarity.
Generally there are three ways to program this detector:

As internal sensor.

This sensor is not monitored if the

selection switch

is in position I.

This means that you can move freely around the house without setting off an alarm. If the

selection switch

is on position II/III and the system is armed, any motion will trigger alarm.

As Entry/Exit sensor.

If the system is armed any motion will trigger an alarm after a

waiting period (entry delay) of 20 seconds. During this period you can disarm the system
with your telecommand or key switch .

As external sensor.

If the system is armed any motion will trigger an alarm without delay

independent from the position of the

selection switch

.

As presence detector.

In this role the detector looks for motion within a certain time

frame. Implementation of this function comes under surveillance of a person in need of
care. The detector should be positioned in such a way (corridor, kitchen, bathroom) that it
is triggered through activity of the person in need of care at least every 24h. If this does not
happen, the radio alarm unit starts dialling the stored emergency member.

Mode jumper:

FULL SIGN: no latency period between alarm detection
NORM:

2.5 min latency period (battery saving mode)

Learn-in procedure:

Close upper shell of motion detector => LED immunities after a few

seconds, if not open upper shell again and close after waiting 3 seconds.

Sensor functions:

Intern, Entry/ Exit, Extern (with status report every 65 minutes)

Summary of Contents for EA-8-WRL868

Page 1: ...Motion detector Wireless sensors Magnet Repeater contact Concentrator Alarm Telecommand Key Emergency button LEITRONIC AG Swiss Security Systems HOME SECURITY Use instruction EasyAlarm HOME Motion det...

Page 2: ...alling in check call 21 6 11 Answering an incoming call 21 7 Useful notes 22 7 1 Tone dialling command 22 7 2 User information 22 7 3 Functional checks 23 7 4 Battery check replacement 24 7 5 Maintena...

Page 3: ...ensors alarm can be disabled easily EasyAlarm can be used as remote switch With the appropriate accessory for example a light or siren can be activated or deactivated during the phone connection o Sir...

Page 4: ...disconnect 2 3 Wireless sensors 868 65MHz permit according to description of wireless sensors 2 4 Power supply A transformer according to the safety regulation EN60950 provides power supply or by 9V b...

Page 5: ...er programming If function switch is on position ON pressing any key will start a test call Keys are marked with 1 2 3 4 5 6 7 8 9 0 in the following sections 4 Loudspeaker The integrated loudspeaker...

Page 6: ...apter into one of the EXT ports of the alarm unit and plug AC adapter to main socket 230V Optional wired sensors Operation with motion detector BBT PIR RJ45 Detail section 10 1 Operation with alarm co...

Page 7: ...92 RWT 33 RWT 72 CON 868 Location 0 1 2 3 4 5 6 7 8 9 Learn in radio sensor Details according to section 5 5 16 Slide function switch to PROG 17 Enter 18 Press 0 to 9 according to desired zone per zon...

Page 8: ...safety reasons 5 1 1 Point ID Contact ID alarm protocol If the alarm should be transferred to a alarm organisation using the Point ID Contact ID protocol the alarm number has to be followed by key an...

Page 9: ...alling of a new number starts without delay You can demand the difference alarm sequence in each selection switch I II III this typical of alarm sequence definite in section 9 9 5 3 How to select user...

Page 10: ...id false learn in of another sensor like a activated motion sensor The alarm unit can handle up to 10 zones The zone number 0 9 is used to identify the location of the sensor in alarm The order of the...

Page 11: ...ne n to modify press star 5 Press key 6 Slide function switch to OFF Important note If the tamper contact of a telecommand key switch or remote lock sensor function 9 and 0 is detected the appropriate...

Page 12: ...Paying attention to mounting it onto a flat surface and that the sabotage contact on the back is pressed in put the shell back on Bolt the upper shell with the four special screws Learn in procedure...

Page 13: ...llance takes place Preparation procedure for programming If not yet open open the detector with a screwdriver on the bottom and remove the upper from the lower shell Take the 3V lithium battery from i...

Page 14: ...t ON Slow 500ms for operation with external magnets OFF Fast 10 ms for operation with shock sensors 7 Determinate HOLD Status of transmitter ON There will be a 2 5 min dead time between two transmissi...

Page 15: ...D green If a contact is in alarm position the entire zone is deemed to be open LED yellow The status control battery supervision of the detectors will also be concentrated which means notification of...

Page 16: ...llows A Add up the entire individual values according to following table that your needs Total n Value Explanation 1 Acoustical monitoring is disabled on position III high sensitivity 2 Acoustical mon...

Page 17: ...of the contact open close after power up can be selected according to section 9 11 2 The default value is all contacts are open The state of any contact zone will than be auto synchronised after the...

Page 18: ...Sensor 1 2 Instantaneously Listening in Alarm due to sensor 1 Sensor 2 3 Instantaneously Listening in Alarm due to sensor 2 Power failure 4 Delay 1 min Hands free Alarm due to power failure 1 Factory...

Page 19: ...delayed due to following reasons An alarm sensor in the area of the entrance must be delayed to have enough time to switch off the supervision mode before EasyAlarm dials the first calling number A pr...

Page 20: ...ands free connection you can increase volume by pressing local key or decrease by pressing locale key Level can be adjusted in fifteen steps 1dB each and remains stored 6 7 5 Acknowledge alarm Termina...

Page 21: ...ep dialling in procedure is for security reasons to avoid detecting of the alarm unit coincidently by an unknown caller Direct dialling in as well as other number of ringing cycles can be selected sec...

Page 22: ...low battery status or there is a mains power loss at the concentrator itself If there is a mains power loss at the repeater than the first repeated zone would also announce low battery status Calling...

Page 23: ...an the first repeated zone would also announce low battery status Emergency call activated Emergency call initiated by emergency button Output activated deactivated Confirm through press DTMF 6 DTMF 4...

Page 24: ...ated wireless component should be replaced immediately as follows Pay attention to the note here that is special indication for sensor in question Important notes If the battery of the telecommand key...

Page 25: ...s not answering the phone Remote access using dialling in not possible EasyAlarm is not responding to the call The dialling function is programmed for the two step modus section 0 Remote access using...

Page 26: ...although the sensor LED is on Sensor not learned in Sensor deactivated at current position of the selection switch Detector is not monitored if system is disarmed or during exit delay respectively Pre...

Page 27: ...arm as long until an acknowledgement is received OFF ON PROG 9 7 1 3 5 3 Value OFF ON PROG Value Comment 0 EasyAlarm calls the alarm numbers within the calling number sequence just once 1 9 EasyAlarm...

Page 28: ...g with cord with end sleeves 9 6 2 Wiring Switzerland with T T SW06 1 Plug adapter SW06 into wall plate 2 Connect FCC cord between alarm unit and adapter SW06 3 Plug downstream phone into T T Jack of...

Page 29: ...ction This function is disabled factory setting but can be enabled as follows 9 8 1 Enabling of remote programming Remote programming can be read out or modified as follows OFF ON PROG 9 7 1 3 7 6 Val...

Page 30: ...hannel experience interference during reception or the detector is on the boarder of reception area If a detector does not report its status within supervision time then EasyAlarm will trigger an alar...

Page 31: ...due to sensor 1 sensor 1 activated 10 1 4 Deactivation If the motion detector is not plugged in EasyAlarm automatically deactivates the supervision of the motion detector 10 1 5 Specification Supply...

Page 32: ...o GND Sensor 1 is a normally closed contact Let Sensor 2 input open Sensor 1 is a normally open contact Select the appropriate contact to fit the monitoring 10 2 2 2 Operation with up to three alarm c...

Page 33: ...0 0 1 1 1 0 Unused Gong on Gong type 000 I II III 00 Gong 0 1 1 01 0 enabled 10 Individual message 1 disabled 11 Beep loud 5 Press key The new register bit 7 bit 0 will be announced 6 Slide function s...

Page 34: ...Shift function switch to PROG 2 Enter sequence 9 3 1 7 6 1 Current register bit 7 bit 0 will be announced followed by to modify press to stop press 3 If you want to keep current value proceed with ste...

Page 35: ...mains unacknowledged siren floodlight C Output is activated during phone connection by request siren floodlight 10 5DIN Adapter interface EA ACDC SWI RJ45 Primary voltage 230 VAC 50 Hz Secondary volta...

Page 36: ...nsion 70 x 30 x 60 mm L x W x H Weight 102 g Cord length 3 m RJ45 11 3Warranty Dear customer Each EasyAlarm is manufactured and tested according to stringent quality rules If the unlikely case should...

Page 37: ...on 3 4 5 6 9 10 11 17 18 19 20 21 23 25 28 29 32 34 35 40 hands free 5 7 8 18 19 20 21 23 29 40 volume 20 listening in 7 19 20 21 29 35 40 time out 20 21 Contact sensor 7 8 14 26 32 40 Cord 4 5 6 24 2...

Page 38: ...7 18 22 23 25 26 30 31 32 33 34 35 40 function 7 10 11 15 17 18 19 22 23 26 function type 7 10 11 12 14 15 40 motion 3 10 17 23 wired 16 Siren 3 33 34 35 Supervision active mode 18 20 22 23 inactive m...

Page 39: ...39...

Page 40: ...upervision mode without acoustical monitoring Supervision mode with acoustical monitoring Supervision mode inactive During phone connection Alarm release independent from state of arming armed disarme...

Reviews: