AS-3901-B and -C Installation and Operation Manual
23
Chapter 3: Operation
Navigating the Operator and All Lists
To navigate, and then view or change a parameter from the Operator
and All Lists, follow these steps:
1. Open the front panel of the NEO frame.
2. Press any card-edge control to turn on the VFD screen.
The message
AS-3901-B or AS-3901-C
appears. If
a previous user
has left the display at a different parameter name, repeatedly press
the
Escape
button until the message
AS-3901-B or AS-3901-C
appears.
3. Push the
Enter
button.
The name of the first parameter option in the list appears.
4. Push the
Enter
button again to access the options for the parameter
displayed on the VFD screen.
OR
Press the
Nav+/Nav-
switch down repeatedly to view other
parameters, and then press
Enter
to access an item’s parameter
options.
5. Press the
Nav+/Nav-
switch up or down to scroll through the
different selectable parameter options, and then press
Enter
to
select the value you want.
OR
Press the
Nav+/Nav-
switch up or down to adjust the numeric
parameter value, and then press
Enter
.
6. Close the front panel of the frame to ensure the cooling system
continues to operate properly.
Note
After several seconds of
inactivity, a scrolling message
will appear, describing the
purpose of the currently selected
parameter.
Summary of Contents for Neo AS-3901-B
Page 4: ...Edition C May 2005 AS 3901 B and C Audio Synchronizers Installation and Operation Manual ...
Page 5: ......
Page 9: ...vi AS 3901 B and C Installation and Operation Manual Contents ...
Page 15: ...xii AS 3901 B and C Installation and Operation Manual Preface ...
Page 53: ...38 AS 3901 B and C Installation and Operation Manual Chapter 4 Specifications ...
Page 67: ......