DM515

°F°C

INSTRUCTION MANUAL

ENGLISH

DM515

True RMS 1000V Digital Multimeter 

w/Temperature

1000V

CAT II

600V

CAT III

99 Washington Street 
Melrose, MA 02176 

Phone

 781-665-

1400

Toll Free 1-800-517-8431

Visit us at www.T

estEquipmentDepot.com

Summary of Contents for DM515

Page 1: ...A MAX FUSED MAX CAT III 600V CAT II 1000V DM515 F C INSTRUCTION MANUAL ENGLISH DM515 True RMS 1000V Digital Multimeter w Temperature 1000V CAT II 600V CAT III 99 Washington Street Melrose MA 02176 Pho...

Page 2: ...LEANING 4 OVERVIEW 5 SYMBOLS 6 OPERATING INSTRUCTIONS AC DC Voltage 1000V AC DC 6 Resistance 40M 7 Continuity 7 Diode 8 Capacitance 8 AC DC Microamps 6000 A 9 AC DC Milliamps 400mA 9 AC DC Amps 10A 10...

Page 3: ...t 2000m Display 6 000 Backlight Yes Over range OL is displayed Dimensions 6 49 x 3 3 x 2 17 Item Weight 15 0 oz Calibration Recommended annually CAT Rating CAT III 600V CAT II 1000V Certifications cEL...

Page 4: ...t shock and arc blast injury where hazardous live conductors are exposed Always turn off power to a circuit or assembly under test before cutting unsoldering or breaking the current path Even small am...

Page 5: ...Press and hold to return to live readings E Select Button Press to select AC DC or Auto Selection in the following functions Voltage A mA Amps Press to select C or F in the Temperature function F Func...

Page 6: ...lts DC RMS at either the common or multifunction input ports as measured from earth ground Features RANGE MIN MAX HOLD SEL RANGE SEL Temp A True RMS MIN MAX HOLD FAST V Apo A mA A A mA 10A MAX FUSED 4...

Page 7: ...load Protection Approx 1 0V Approx 40 600V Features MIN MAX HOLD Buzzer sounds at less than 40 WARNING Do not measure resistance on a live circuit Continuity RANGE SEL Temp A True RMS MIN MAX HOLD FAS...

Page 8: ...IN MAX HOLD FAST V Apo A mA A A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V DM515 F C A A mA F C Apo DM515 V Forward Bias Displays approx voltage drop RANGE SEL Temp A True RMS MIN...

Page 9: ...Accuracy Resolution Overload Protection 60mA to 400mA 1 2 5 dgts 0 01mA to 0 1mA 600mA 1000V Fast Fuse Minimum sensitivity 5mA AC auto selection mode only DCmA Ranges Accuracy Resolution Overload Prot...

Page 10: ...to selection mode only CAUTION 20A overload for 30 seconds max F Ranges Accuracy Resolution Overload Protection 328 to 999 F 1 5 3 6 F 0 1 F 600V 1000 to 2462 F 1 5 3 0 F 1 F C Ranges Accuracy Resolut...

Page 11: ...low testing on recessed conductors such as standard wall outlets Take care not to lose the shields WARNING Test lead category protections apply only to test leads and should not be confused with the m...

Page 12: ...ding the limits mentioned in the General Specifications section allow the instrument to return to normal operating conditions before using it Copyright 2018 Kane USA Inc All Rights Reserved 17489 0118...