OVERVIEW

RANGE

SEL

Temp

A

True RMS

MIN/MAX

HOLD

FAST

V

Apo

µA

mAµA

A

mA

  10A

MAX

FUSED

  

400mA

MAX

FUSED

MAX

CAT III

600V

CAT II

1000V

DM515

°F°C

B

A

C

G

J

K

L
M

N

O

H

E

F

I

D

A. Apo: 

Auto power off after 30 minutes of use. Press  

and hold the HOLD button while turning the meter on  

  to disable Apo.

B.  Digital Backlit Display

C.  Range Button

• Press to change from auto ranging to 

manual ranging.

• Press repeatedly to select proper range.

• Press and hold to return to auto range 

(AT will be displayed on screen).

D.  Min/Max Button

• Press to enter MAX/MIN mode.

• In the V, μA, mA or Amps function, either select 

AC/DC or change to manual ranging before pressing 

this button to enter MAX/MIN mode.

• Press repeatedly to alternate between Maximum and 

Minimum readings.

• Press and hold to return to live readings.

E.  Select Button:

 

• Press to select AC, DC or Auto Selection in the

following functions: Voltage, μA, mA, Amps.

• Press to select °C or °F in the Temperature function.

F.  Function Dial:

 Turns on meter and is used to select  

  the function.

G.  Hold/Fast Button

• Press to hold the reading on the display. Press again 

to return to live reading.

• Press to enter Fast MAX/MIN mode in

MAX/MIN mode.

• Press again to return to normal MAX/MIN mode.

H.  Back Light Button:

 Press to on back light. Press again  

  to turn off. Back light duration is 1 minute.

I.  Category Max Indicator:

 Maximum CAT Rating for  

fused input jacks.     

•  Multifunction input port used for measuring: AC or 

DC volts, resistance, continuity, diode, capacitance  

µA,.mA, Amps, Temperature.

•  Use CATIII test leads or higher

J.  Recess for magnetic hanger

K.  Test Lead Holders 

L.  Protective Rubber Boot

M. Battery Cover (under protective rubber boot)

N.  Kick Stand

O.  Serial Number (under kick stand)

Summary of Contents for DM515

Page 1: ...A MAX FUSED MAX CAT III 600V CAT II 1000V DM515 F C INSTRUCTION MANUAL ENGLISH DM515 True RMS 1000V Digital Multimeter w Temperature 1000V CAT II 600V CAT III 99 Washington Street Melrose MA 02176 Pho...

Page 2: ...LEANING 4 OVERVIEW 5 SYMBOLS 6 OPERATING INSTRUCTIONS AC DC Voltage 1000V AC DC 6 Resistance 40M 7 Continuity 7 Diode 8 Capacitance 8 AC DC Microamps 6000 A 9 AC DC Milliamps 400mA 9 AC DC Amps 10A 10...

Page 3: ...t 2000m Display 6 000 Backlight Yes Over range OL is displayed Dimensions 6 49 x 3 3 x 2 17 Item Weight 15 0 oz Calibration Recommended annually CAT Rating CAT III 600V CAT II 1000V Certifications cEL...

Page 4: ...t shock and arc blast injury where hazardous live conductors are exposed Always turn off power to a circuit or assembly under test before cutting unsoldering or breaking the current path Even small am...

Page 5: ...Press and hold to return to live readings E Select Button Press to select AC DC or Auto Selection in the following functions Voltage A mA Amps Press to select C or F in the Temperature function F Func...

Page 6: ...lts DC RMS at either the common or multifunction input ports as measured from earth ground Features RANGE MIN MAX HOLD SEL RANGE SEL Temp A True RMS MIN MAX HOLD FAST V Apo A mA A A mA 10A MAX FUSED 4...

Page 7: ...load Protection Approx 1 0V Approx 40 600V Features MIN MAX HOLD Buzzer sounds at less than 40 WARNING Do not measure resistance on a live circuit Continuity RANGE SEL Temp A True RMS MIN MAX HOLD FAS...

Page 8: ...IN MAX HOLD FAST V Apo A mA A A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V DM515 F C A A mA F C Apo DM515 V Forward Bias Displays approx voltage drop RANGE SEL Temp A True RMS MIN...

Page 9: ...Accuracy Resolution Overload Protection 60mA to 400mA 1 2 5 dgts 0 01mA to 0 1mA 600mA 1000V Fast Fuse Minimum sensitivity 5mA AC auto selection mode only DCmA Ranges Accuracy Resolution Overload Prot...

Page 10: ...to selection mode only CAUTION 20A overload for 30 seconds max F Ranges Accuracy Resolution Overload Protection 328 to 999 F 1 5 3 6 F 0 1 F 600V 1000 to 2462 F 1 5 3 0 F 1 F C Ranges Accuracy Resolut...

Page 11: ...low testing on recessed conductors such as standard wall outlets Take care not to lose the shields WARNING Test lead category protections apply only to test leads and should not be confused with the m...

Page 12: ...ding the limits mentioned in the General Specifications section allow the instrument to return to normal operating conditions before using it Copyright 2018 Kane USA Inc All Rights Reserved 17489 0118...

Reviews: