20
8.5 Display symbols of the work display (Display 35)
During operation, the setpoints of the welding parameters (ejection in %, tem-
perature in °C or °F, air volume in % and, if necessary, information notes (see
Application Mode: Showing current values).
• Change welding parameters by pressing
the Minus/Plus button (32)
• after pressing the
Confirm button (33),
the selected parameter can be individually
adjusted by pressing the
Minus/Plus button (32)
Plastic ejection symbol [%]
Plastic temperature symbol [°C or °F]
Symbol air temperature [°C or °F]
Symbol air volume [%]
Welding temperature too low, heat-up process.
•
Up
ward arrow and progress bar indicate if
higher temperature
has not yet been reached
• Flashing value over progress bar indicates current actual value
(205)
• Value to the right of bar (230) indicates setpoint of the selected
welding profile or individual setting
Temperature too high, cool-down process.
•
Down
arrow and progress bar indicate that if the desired
lower
temperature
has not yet been reached, the
• flashing value above the bar indicates the currently reached
actual value (240)
• value to the right of the bar (215) indicates the target value of the
selected welding profile or individual setting
Symbol for Cool-down mode
Symbol for
hardware error message
• Device no longer ready for use
• Contact your authorized Leister Service Center (note the respec-
tive error code in the section Warning and error messages)
Symbol for
Hardware error message
(heating element is defective).
• Device no longer ready for use
• Contact Leister Service Center
Symbol for
Overtemperature warning message.
• Allow the device to cool down.