When fi xing the tool into an installation, the mains connection must have a suitable
device with to disconnect
all poles from the mains
with a
3 mm distance between contacts.
Alarm contact:
SPST– NO 250 VAC / 30 VDC, 3 A
Input 0 – 10 V
Input 4 – 20 mA
Temperature / air volume diagram
4
3.5
3
2.5
2
1.5
1
0.5
0
0
100
200
300
400
500
600
700
Interface / Control
Pre
ss
u
re
[
k
Pa
]
Air volume l / min
Air volume
+ 4 - 20 mA
– 4 - 20 mA
100
90
80
70
60
50
40
30
20
10
0
4
8
12
16
20
Blower power f (control current)
B
lowe
r p
o
we
r [
%
]
Current 4 – 20 [mA]
Air volume
GND
0 - 10 V
100
90
80
70
60
50
40
30
20
10
0
0
2
4
6
8
10
Blower power f (control voltage)
B
lowe
r p
o
we
r [
%
]
Voltage [V]
Alarm contact
COM NO
Alarm contact
COM NO