15
Voltage V~
120
230
Power consumption
W
250
Frequency
Hz
50 / 60
Air volume max. (20 °C)
l/min.
250 – 600
Max. air inlet temperature °C
65
Max. static pressure kPa
3.5
Emission level
L
pA
(dB)
65
Weight kg
1.0
Size
Page 3
Mark of conformity
Approval mark
Protection class II
Technical data MONO 6 SYSTEM
Relay output
Max. voltages
AC 250 V, DC 30 V
Max. currents
AC 3 A, DC 3 A
Max. contact resistance
100 m Ohm bei DC 6 V / 1 A
Type of contact
SPST - NO
Insulation IEC/EN 60065
AC 2000 V (50 - 60 Hz) 1 min
Technical data for interface
Setpoint setting
e-Drive or
interface
e-Drive
1 – 100 %
External interface
1 – 100 %
Signal inputs
with reverse polarity
protection and
zero off set
Insulation IEC/EN 60747-5-2
AC 1414 V Peak
Voltage input Uc in relation
to GND iso
DC 0 - 10 V
Max. input voltage
DC 12 V
Nominal input resistance
7.9 kOhm
Current input Ic (2 - conductor
technology)
DC 4…20 mA
Max. input current
DC 22 mA
Nominal input resistance
168 Ohm
Device function
• Adjustable air volume
• Brushless motor
• Compact and effi cient
• Tool protection
• “e-Drive” operating unit
• System interface
Technical data and specifi cations are subject to change without prior notice