The tool should be earthed using a protective con-
ductor.
The
voltage rating
stated on the tool should corre-
spond to the mains voltage.
Protect the tool from
damp
and
wet.
230
400
Voltage
V~
Frequency
Hz
Capacity
kW
Minimum air flow
l/min
Maximum temperature
°C
Ambient temperature
°C
Weight
kg
Size
mm
3 x 220 – 230
3 x 380 – 440
50 / 60
25 29 – 39
2200
3000 – 4000
650 650
<80 <80
13,2 13, 2
447 x 312 x 306
2
WARNING
CAUTION
TECHNICAL DATA
The equipment should not be operated
without
supervision.
Danger!
When opening up the tool, live components
and connections are exposed. Therefore, before open-
ing it, unplug the tool to ensure disconnection from
the mains.
Incorrect installation and use of hot air tools can
present a
fire and explosion hazard.
The specified
minimum air flow must be absolutely adhered to.
Do not touch the element housing and nozzle when
hot as they can cause
burns.
Do not point the hot air
flow at people or animals.