• Once you have prepared the working area and the hot air welder in accordance with the description, connect the 

hot air welder to the mains voltage.

• Switch the wedge welder on via the 

main switch (10)

.

• Define the 

welding parameters for drive (19),

 

air temperature (22)

 and 

air volume (25)

 on the respective 

potentiometer.

• Now switch on the heating [

Direct heating button (24)

].

• Preparing for welding
• Make sure that the welding temperature has been reached before commencing work.  

The heat-up time is 3 − 5 minutes.

• Now carry out test welds in accordance with the welding instructions of the material manufacturer and/or national 

standards or regulations and inspect the results. Adjust the welding profile as needed.

After the welding, actuate the foot pedal or the 

pressure switch (21)

, the 

motor for generating preheated air 

(1)

 extends and the drive stops automatically.

• Use the 

Direct heating button (24)

 to switch off the heating so that the 

welding nozzle (18)

 cools down.

• The 

LED (23)

 begins flashing at the heating button.

If the device is switched off without the cooling process being adhered to, the device may become severely damaged. 
No warranty or guarantee claims can be made for damage or malfunctions resulting from this.

Commencing welding

• Actuate the 

pressure button (21)

 or the foot pedal to start the welding automatically.

• The drive motor starts automatically as soon as the 

hot-air blowers (1)

 are swiveled in. 

Guiding the material during the welding process

• Guide the material with a good tension during the welding process

Risk of clamping injuries!

A danger of clamping injuries exists with the tilting mechanism when the hot-air blowers swivel in 
and out.

Only switch off the device with the 

main switch (10)

 when 

LED (23)

 stops flashing and disconnect 

the power supply cord from the electrical network.

Wait until the device has cooled down / LED has stopped flashing. If the cooling is not adhered to, the 
device may become damaged. 
Check the power supply cord and plug for electrical and/or mechanical damage.
Clean the two filters of the 

hot-air blowers (1)

 and the 

welding nozzle (18)

 with a wire brush.

Risk of burning! 

Do not touch heating element, nozzle and components in the immediate vicinity 
of the nozzle when hot. The device should always first be allowed to cool down. 
Do not point the hot air flow at people or animals!

Risk of entanglement!

During operation there is a risk of entanglement on the drive roller.

6.4  Starting the device

6.5 Welding 

Sequence

6.6 Finishing 

welding

6.7  Switching off the device / Maintenance

Summary of Contents for HEMTEK K-ST

Page 1: ...Leister Technologies AG Galileo Strasse 10 CH 6056 Kaegiswil Switzerland Tel 41 41 662 74 74 Fax 41 41 662 74 16 www leister com sales leister com HEMTEK ST HEMTEK K ST D GB F...

Page 2: ...3 Insulation silicone plugs only HEMTEK ST 24 5 4 Adjusting the contact pressure weight 25 5 5 Welding nozzle 25 6 Commissioning your HEMTEK ST K ST 27 6 1 Work environment and safety 27 6 2 Operating...

Page 3: ...e auto matic welder e g due to material overheating and particularly in the vicinity of ammable materials and explosive gases Risk of burning Do not touch heating element nozzle and components in the...

Page 4: ...ie up long hair or protect it by wearing headgear Comply with applicable national statutes regarding the carrying or lifting of loads The weight of your HEMTEK ST K ST excluding table fastening is 20...

Page 5: ...Translation of operating instructions 1 Main catalog 1 Folder The hot air blowers 1 MUST be allowed to cool down prior to transport Never use the carrying handle 2 on the device for transporting with...

Page 6: ...amping lever and fixing unit for guide 13 Silicone plugs remove for piping welding 14 Hem open hem and piping guide 15 Drive wheel 16 Pressure wheel 17 Adjustable weight 18 Nozzle 19 Speed potentiomet...

Page 7: ...itch 10 Fastening console guide 11 Clamping lever and fixing unit for guide 12 Double flap piping guide 13 Drive wheel 14 Pressure wheel 15 Adjustable weight 16 Flap piping nozzle 17 Speed potentiomet...

Page 8: ...bolts Check correct seating and stability of the welder Mount HEMTEK ST K ST on table fastening Clamping feet can be adjusted to the differ ent tables using the two socket head screws Two persons are...

Page 9: ...on The guide exhibits diverse engravings which serve as an adjustment aid The recommended basic setting depends on the size of the nozzles Setting may vary depending on the material Guide designation...

Page 10: ...element tube and nozzle when they are hot The device should always rst be allowed to cool down The following is the basic setting of the welding nozzles of your HEMTEK ST B C A A 22 mm Distance of noz...

Page 11: ...is available as an accessory article no 157 098 Dimension A Set 1 socket head screw and slide at the same time with the linear drive Dimension B Set 4 hexagon nut Dimension C Set 4 socket head screws...

Page 12: ...ge When using power plants as an energy supply please ensure that the power plants are grounded and equipped with earth leakage circuit breakers For the nominal output of the power plants the formula...

Page 13: ...be made for damage or malfunctions resulting from this Commencing welding Actuate the pressure button 21 or the foot pedal to start the welding automatically The drive motor starts automatically as s...

Page 14: ...witch 10 5 Pull out mains voltage plug Risk of clamping injuries A danger of clamping injuries exists with the tilting mechanism when the hot air blowers swivel in and out Temperature graph for 100 ai...

Page 15: ...ir service with original spare parts in accordance with circuit diagrams and spare parts lists You will nd the address of your authorized service center on the last page You can nd more information at...

Page 16: ...odel made available for purchase this product fulfills the requirements of the following EU directives Guidelines 2006 42 2014 30 2014 35 2011 65 Harmonized standards EN 12100 EN 55014 1 EN 55014 2 EN...

Page 17: ......

Page 18: ...Centre is Leister Technologies AG Galileo Strasse 10 CH 6056 Kaegiswil Switzerland Tel 41 41 662 74 74 Fax 41 41 662 74 16 www leister com sales leister com Copyright by Leister BA HEMTEK ST K ST 11 2...

Reviews: