10
The local supply
voltage
must match the nominal
voltage
specified on the device.
Incorrect mains
voltage
can cause the device
to
fail. The main switch must be switched off in the event of a mains
voltage failure.
Risk of burns
The device may only be operated at intervals. If the on duration is too long (>2min), the temperature
on the motor housing can cause burns.
Always allow the device
to cool down. The device can only
be operated using the handles and switches provided. The main switch must be switched off in the
event of a mains voltage failure.
Be aware of hazards in the surrounding area, e.g., risk of tripping, risk of slipping, strong sunlight,
unattended equipment, etc.
Note
Caution
230 V~ up to 50 m
3 × 1.5 mm
2
up to 100 m
3 × 2.5 mm
2
120 V~ up to 50 m
3 × 1.5 mm
2
up to 100 m
3 × 2.5 mm
2
Power cord and extension cable
• The
power cord (1)
must be able to move freely and must
not hinder the user or third parties during work (trip hazard).
• The extension cables must be authorized for the utilization
site (such as, outdoors) and be marked accordingly. Take the
necessary minimum cross-section for extension cables into
account as required.
On-site generators for power supply
When using on-site generators as a power supply, please ensure that the generators are equipped with residu-
al-current circuit breakers.
The formula "2 × nominal power of the devices used" applies to the nominal power of generators.